Spectrofluorimetric Determination of Iproniazid and Isoniazid in a FIA System Provided with a Solid-Phase Reactor

1998

Abstract A FIA assembly is proposed for the fluorimetric determination of iproniazid and isoniazid. The oxidation of both drugs is carried out by H2O2. The excess of reagent is destroyed and removed from the flow-injection manifold by means of a metallic copper reactor which acts as catalyst in the decomposition of H2O2 and a home made debubbler. The calibration graphs were linear up to 14 μg ml−1 and 10 μg ml−1 (n=6) for iproniazid and isoniazid, respectively, with limits of detection of 0.008 μg ml−1 and 0.005 μg ml−1. The sample throughput was 24 h−1 for both drugs. The influence of foreign compounds was studied and the procedure was applied to determination of iproniazid and isoniazid i…

Detection limitChromatographyChemistryBiochemistry (medical)Clinical BiochemistryIsoniazidFluorescence spectrometryBiochemistryDosage formAnalytical ChemistryIproniazidReagentPhase (matter)ElectrochemistrymedicineQuantitative analysis (chemistry)Spectroscopymedicine.drugAnalytical Letters
researchProduct

FI-on line photochemical reaction for direct chemiluminescence determination of photodegradated chloramphenicol.

2002

Abstract A new, simple, clean and selective flow injection strategy based on the tandem photochemical reaction-chemiluminescence detection was applied to the determination of chloramphenicol. The determination is based on the on-line photodegradation of the drug in a glycine buffer at pH 8.8 by using a photoreactor consisting of 697 cm×0.5 mm PTFE tubing helically coiled around an 8 W low-pressure mercury lamp. Photodegradated chloramphenicol is detected by direct chemiluminescence of resulting photo-fragments and their subsequent reaction with potassium permanganate in sulfuric acid medium as oxidant. The method allows the chemiluminescence determination of compounds which do not exhibit n…

Detection limitChromatographyChemistryCalibration curvePhotochemistryDosage formAnalytical Chemistrylaw.inventionPotassium permanganatechemistry.chemical_compoundlawPhotodegradationQuantitative analysis (chemistry)Antibacterial agentChemiluminescenceTalanta
researchProduct

Determination of catecholamines in urine by micellar liquid chromatography with coulometric detection

1994

The determination of catecholamines by HPLC with a sodium dodecyl-sulphate (SDS), micellar mobile phase on a C18 column and with coulometric detection was studied. The eluate was conditioned at +0.25 and +0.00 V, and the current at −0.16V was recorded. A previously developed model which describes the chromatographic behaviour of solutes in HPLC with hybrid, micellar mobile phases was used to optimize the SDS and ethanol concentrations. A mobile phase of 0.15M SDS in a phosphate buffer of pH 3.4 and without ethanol is recommended. The limits of detection were 0.4–0.7 ng ml−1. The procedure was applied to the determination of unconjugated L-dopa, norepinephrine and dopamine in urine. Direct i…

Detection limitChromatographyChemistryElutionSodiumOrganic ChemistryClinical BiochemistryExtraction (chemistry)chemistry.chemical_elementBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryCoulometryMicellar liquid chromatographyQuantitative analysis (chemistry)Chromatographia
researchProduct

Sequential injection spectrophotometric determination of oxybenzone in lipsticks

2001

A sequential injection (SI) procedure for the spectrophotometric determination of oxybenzone in lipsticks is reported. The colorimetric reaction between nickel and oxybenzone was used. SI parameters such as sample solution volume, reagent solution volume, propulsion flow rate and reaction coil length were studied. The limit of detection was 3 microg ml(-1). The sensitivity was 0.0108+/-0.0002 ml microg(-1). The relative standard deviations of the results were between 6 and 12%. The real concentrations of samples and the values obtained by HPLC were comparable. Microwave sample pre-treatment allowed the extraction of oxybenzone with ethanol, thus avoiding the use of toxic organic solvents. E…

Detection limitChromatographyChemistryExtraction (chemistry)CosmeticsBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryVolumetric flow rateBenzophenoneschemistry.chemical_compoundVolume (thermodynamics)SpectrophotometryReagentElectrochemistryEnvironmental ChemistryOxybenzoneQuantitative analysis (chemistry)SpectroscopyThe Analyst
researchProduct

Simultaneous determination of olanzapine, clozapine and demethylated metabolites in serum by on-line column-switching high-performance liquid chromat…

2001

An automated method for simultaneous routine quantification of the antipsychotic drugs clozapine, olanzapine and their demethylated metabolites is described. The method included adsorption on a cyanopropyl (CPS) coated clean-up column (10 microm; 10 x 2.0 mm I.D.), washing off interfering serum constituents to waste, and separation on C18 ODS Hypersil reversed phase material (5 microm; 250 x 4.6 mm I.D.) using acetonitrile-water-tetramethylethylenediamine (37:62.6:0.4, v/v/v) adjusted to pH 6.5 with concentrated acetic acid. UV-detection was performed at 254 nm. The limit of quantification was 10-20 ng/ml. Relative day to day standard variations ranged between 4.5 and 13.5%. The method is s…

Detection limitChromatographyChemistryMetaboliteReproducibility of ResultsGeneral ChemistryPirenzepineHigh-performance liquid chromatographySensitivity and SpecificityAcetic acidchemistry.chemical_compoundBenzodiazepinesAdsorptionPharmacokineticsOlanzapinemedicineHumansSpectrophotometry UltravioletQuantitative analysis (chemistry)ClozapineClozapineChromatography High Pressure Liquidmedicine.drugAntipsychotic AgentsJournal of chromatography. B, Biomedical sciences and applications
researchProduct

Determination of synthetic antioxidants in dairy products and dietetic supplements by micellar liquid chromatography with direct sample injection

2000

A simple and rapid HPLC method for the determination of synthetic antioxidants (propyl gallate, tert-butylhydroquinone, 2,4,5-trihydroxybutyrophenone, nordihydroguaiaretic acid, octyl gallate, 3-tert-butyl-4-hydroxyanisole and dodecyl gallate) in powdered and liquid milk, cream of milk and dietetic supplements is described. The samples are diluted or solved in a micellar solution, filtered and directly injected. The retention behavior of the antioxidants on a C18 column, with micellar mobile phases containing SDS (0.05–0.15 M), n-propanol (1–9%, v/v) and 10 mM phosphate at pH 3, has been studied by using mathematical models. Retention is predicted with errors below 3%. To optimize the mobil…

Detection limitChromatographyChemistryOrganic ChemistryClinical BiochemistryDodecyl gallateBiochemistryHigh-performance liquid chromatographyMicellar electrokinetic chromatographyAnalytical Chemistrychemistry.chemical_compoundMicellar liquid chromatographyOctyl gallateQuantitative analysis (chemistry)Propyl gallateChromatographia
researchProduct

High-performance liquid chromatographic determination of sumatriptan after in vitro transdermal diffusion studies.

2004

A simple, accurate, precise and rapid HPLC method with UV detection has been validated in order to determine the in vitro transdermal absorption of sumatriptan succinate. The HPLC method is a modification of that described by Nozal et al. [M.J. Nozal, J.L. Bernal, L. Toribio, M.T. Martin, F.J. Diez, J. Pharm. Biomed. Anal. 30 (2002) 285-291]. Separation was carried out on a 250 mm Kromasil C18 column at room temperature. The detector response, at 282.7 nm, was found to be linear in a concentration range between 0.145 and 145 microM. The limit of detection (LOD) was 0.019 microM and the limit of quantification (LOQ) was 0.145 microM.

Detection limitChromatographyChemistrySumatriptanSwineDiffusionSkin AbsorptionClinical BiochemistryAnalytical chemistryPharmaceutical ScienceAbsorption (skin)Reversed-phase chromatographyIn Vitro TechniquesAdministration CutaneousHigh-performance liquid chromatographyAnalytical ChemistrySumatriptan SuccinateDrug DiscoveryAnimalsDiffusion Chambers CultureQuantitative analysis (chemistry)SpectroscopyChromatography High Pressure LiquidTransdermalSkinJournal of pharmaceutical and biomedical analysis
researchProduct

High-performance liquid chromatographic determination of tocopherols in infant formulas

2002

A method for the simultaneous determination of alpha-tocopherol acetate and alpha-, delta-, and gamma-tocopherols by normal-phase high-performance liquid chromatography (HPLC) with a fluorescent detector in infant formula is proposed. The values obtained in the determination of the analytical parameters: linearity, precision, limit of detection and accuracy (analysis of a standard reference material, SRM 1846), confirm the quality of the method. The proposed method is useful for the determination of alpha-, delta-, and gamma-tocopherols and alpha-tocopherol acetate in infant formulas at a low cost and in a total time of 2 h.

Detection limitChromatographyChemistryVitamine eOrganic ChemistryDetectorAnalytical chemistryInfantReproducibility of ResultsTocopherolsfood and beveragesLinearityGeneral MedicineSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical ChemistrySpectrometry FluorescenceHumansInfant FoodQuantitative analysis (chemistry)Chromatography High Pressure LiquidAnalysis methodJournal of Chromatography A
researchProduct

Determination of arsenic and antimony in milk by hydride generation atomic fluorescence spectrometry

2002

Abstract A highly sensitive procedure has been developed for total arsenic and antimony determination in milk samples by hydride generation atomic fluorescence spectrometry after microwave-assisted sample digestion. The discrete introduction of 2 ml of digested sample in the automated continuous flow hydride generation system allows us to reduce drastically the sample and HCl consume and to determine several elements from a same sample digestion. The method provides detection limits of 0.006 and 0.003 ng ml−1, a sensitivity of 2390 and 2840 fluorescence units per ng ml−1 for As and Sb respectively, and average relative standard deviation of 2.3% for As and 4.8% for Sb. The analysis of cow m…

Detection limitChromatographyDigestion (alchemy)chemistryAntimonyHydrideFluorescence spectrometryAnalytical chemistrychemistry.chemical_elementQuantitative analysis (chemistry)Inductively coupled plasma mass spectrometryArsenicAnalytical ChemistryTalanta
researchProduct

On-line solvent recycling: a tool for the development of clean analytical chemistry in flow injection Fourier transform infrared spectrometry. Determ…

1998

Abstract A flow injection strategy has been developed for the direct determination of ketoprofen in pharmaceuticals by Fourier transform infrared spectrometry also incorporating a distillation unit which allows the carbon tetrachloride employed to dissolve samples and standards and used as a carrier to be recovered on-line. The system developed permits a drastic reduction of reagent consumption and easy and fast sampling and cleaning of the measurement cell. For the quantification of ketoprofen in pharmaceuticals the carbonyl bands at 1712 and 1666 cm −1 were employed and the developed method provided a 3 σ limit of detection of 0.04 mg ml −1 , a dynamic range up to 10 mg ml −1 and typical …

Detection limitChromatographyDynamic rangeChemistryAnalytical chemistryInfrared spectroscopyBiochemistryAnalytical Chemistrylaw.inventionSolventsymbols.namesakeFourier transformlawReagentsymbolsEnvironmental ChemistryQuantitative analysis (chemistry)DistillationSpectroscopyAnalytica Chimica Acta