Search results for "electrodes"
showing 10 items of 231 documents
Sensor Properties of Pristine and Functionalized Carbon Nanohorns
2016
Nanodispersions of pristine single-wall carbon nanohorns (i.e., p-SWCNHs) and oxidized-SWCNHs (i.e.; o-SWCNHs) were used to modify screen printed electrode (SPE). p-SWCNHs and o-SWCNHs were fully characterized by using several analytical techniques, as: HR-TEM (High Resolution-Transmission Electron Microscopy), FE-SEM/EDX (Field Emission-Scanning Electron Microscopy/Energy Dispersive X-ray Analysis), Raman spectroscopy, thermogravimetric analysis, differential thermal analysis (DTA), and the Brunauer-Emmett-Teller (BET) method. The chemically modified SPEs were also characterized with Cyclic Voltammetry (CV), using several different electro-active targets. In all cases, p-SWCNHs showed bett…
Solid-State Electrochemical Assay of Heme-Binding Molecules for Screening of Drugs with Antimalarial Potential
2013
The interaction between heme and ligands is the basis for a variety of tests aimed at the discovery of antiplasmodial molecules. Two electrochemical methods for the screening of molecules with potential antimalarial activity through heme-binding mechanism are described. The first method is applicable to lipophilic environment, by using solution phase electrochemistry in DMSO solutions of Fe(III)-heme plus the tested compounds at carbon electrodes. This method provides well-defined voltammetric signals, characteristic of the heme-ligand (L) interaction. The second method involves aqueous media at biological pH and the use of voltammetry of immobilized particles, by means of microparticulate …
Diffusion in slice preparations bathed in unstirred solutions
1987
A diffusion model is described here, which allows for the estimations of drug concentration changes in porous media, such as in slice tissues of the central nervous system (CNS) bathed in unstirred solutions following abrupt changes of drug concentration. This model may be used for the interpretation of data obtained in neuropharmacological studies if (i) the diffusion coefficient of the molecules under investigation is constant within the excised tissue, (ii) drug molecules are diffusing only in the extracellular space (ECS) and are not bound by the tissue, (iii) drug molecules diffuse mainly within one dimension, (iv) the drug concentration in the bath is changed within 5 s, and (v) the b…
Relationship between the caudate nucleus and the dorsal hippocampus, in the cat.
1972
Performance of interdigitated nanoelectrodes for electrochemical DNA biosensor.
2003
An electrochemical methodology for bio-molecule sensing using an array of well-defined nanostructures is presented. We describe the fabrication by e-beam lithography of nanoelectrodes consisting of a 100 micro m x 50 micro m area containing interdigitated electrodes of 100 nm in width and interelectrode distance of 200 nm. Sensitivity and response time of the nanoelectrodes are compared to the responses of macro- and microelectrodes. The specificity of the sensor is studied by modifying the gold electrodes with DNA. The technique enables to characterize both single and double-stranded DNA of 15 nucleotides. A special electrochemical cell is adapted to control the temperature and measure the…
Asymmetries in classically conditioned head movements and cingulate cortex slow potentials in cats.
1991
Presuming that conditioned head movements in the cat indicate a preference for a specific direction, asymmetries were also expected to be found in bilaterally recorded cingulate cortex slow potentials to a symmetrical tone stimulus during discriminative conditioning. Conditioned stimuli (CS, 1000 and 2500 Hz tones) were delivered through two miniature loudspeakers fitted to the head in front of both ears. The unconditioned stimulus (US) was an electrical stimulation of either the left or right lateral hypothalamus yielding, in addition to its rewarding effects, an unconditioned head turning response (UR) either to the left, right, forwards or upwards. Discrimination learning appeared as mor…
Electrochemistry of TiO2–iron hexacyanocobaltate composite electrodes
2014
Abstract In this paper we investigate the electrochemical behavior of iron hexacyanocobaltate (FeHCC) in comparison to the cobalt hexacyanoferrate (CoHCF). The best results were achieved on electrochemical synthesized film of FeHCC on the TiO2 modified electrodes. The chemical and physical characterizations confirm the formation of the FeHCC with the classical cubic crystal structure of the Prussian blue analogs, with cell parameter a very close to 10 A, as well as the formation of micro aggregates of TiO2 covered by FeHCC. The synthesis was performed on various substrates such as glassy carbon (GC), graphite foil (GF) and indium tin oxide (ITO) in order to develop new technological applica…
Quantification and automatized adaptive detection of in vivo and in vitro neuronal bursts based on signal complexity.
2015
In this paper, we propose employing entropy values to quantify action potential bursts in electrophysiological measurements from the brain and neuronal cultures. Conventionally in the electrophysiological signal analysis, bursts are quantified by means of conventional measures such as their durations, and number of spikes in bursts. Here our main aim is to device metrics for burst quantification to provide for enhanced burst characterization. Entropy is a widely employed measure to quantify regularity/complexity of time series. Specifically, we investigate the applicability and differences of spectral entropy and sample entropy in the quantification of bursts in in vivo rat hippocampal meas…
Influence of device geometry on sensor characteristics of planar organic electrochemical transistors.
2009
The response of PEDOT:PSS planar electrochemical transistors to H2O2 can be tuned by varying the ratio between the areas of the channel and the gate electrode. Devices with small gates show lower background signal and higher sensitivity. The detection range, on the other hand, is found to be rather independent of the gate/channel area ratio.
An electrochemical DNA biosensor for the detection of CTX-M extended-spectrum β-lactamase-producing Escherichia coli in soil samples
2013
International audience; An electrochemical hybridization assay involving neutravidin-coated carbon screen-printed electrodes and an HRP-based detection have been shown to provide an effective tool for the genotypic analysis of extended-spectrum beta-lactamase-producing E. coli strains in complex samples such as soil. (c) 2012 Elsevier B.V. All rights reserved.