Search results for "liquid"
showing 10 items of 4351 documents
Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring
2017
A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g. injection of 100 non-filtrated water samples would did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 µm). In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for …
High pressure liquid chromatography resolution of racemic mixtures of chiral tricarbonyl arene chromium(0) and cyclopentadienyl-titanium(IV) complexes
1998
Abstract Enantiomers of chiral tricarbonyl arene chromium(0) and cyclopentadienyl-titanium(IV) complexes have been separated by high pressure liquid chromatography employing a Chiralcel OD (Daicel) column, eluting with hexane/2-propanol mixtures. The capacity factors ( k ) and selectivity factors ( α ) concerning the separation of these compounds have been determined. The resolution of tricarbonyl( η 6 -methyl o -acetylbenzoate)chromium ( IV ), was carried out on semipreparative scale: a comparison of the CD spectra of the enantiomers IVa and IVb with that reported in the literature for a similar complex allowed to establish the absolute configuration [( 1R )] for the most retained enantiom…
Optimization of a LC method for the enantioseparation of a non-competitive glutamate receptor antagonist, by experimental design methodology
2006
Abstract The aim of this work was to obtain the direct optical resolution of a new glutamate receptor antagonist (( p -chloro)1-aryl-6,7,-dimethoxy-1,2,3,4-tetrahydroisoquinoline, PS3), by liquid chromatography on Chiralcel ® OD column. A response surface methodology (RSM) was employed to optimize the enantiomeric separation of the racemate with the lowest number of experiments; in particular, a face-centred design (FCD) was applied to evaluate the influence of critical parameters on the experimental response. Furthermore, in order to find the best compromise between several responses, a multicriteria decision-making approach, the Derringer's desirability function, was successful to simulta…
Characterization of the alcoholic fraction of vegetable oils by derivatization with diphenic anhydride followed by high-performance liquid chromatogr…
2008
Abstract Aliphatic and triterpene alcohols present in vegetable oils have been identified and determined by HPLC using UV–vis and MS detection after previous derivatization with diphenic anhydride. The alcoholic fraction was obtained by saponification, extraction and TLC (according to the European Union official procedure). Derivatization was performed in tetrahydrofuran in the presence of suspended grinded urea, which increases the reaction rate and yield. Derivatized extracts were chromatographed on a C8 column using gradient elution with acetonitrile/water mixtures containing 0.1% acetic acid, with UV–vis followed by negative-ion mode MS detection. Using linear discriminant analysis of t…
Trace analysis by ion mobility spectrometry: From conventional to smart sample preconcentration methods. A review.
2018
Ion mobility spectrometry (IMS) is a rapid and high sensitive technique widely used in security and forensic areas. However, a lack of selectivity is usually observed in the analysis of complex samples due to the scarce resolution of the technique. The literature concerning the use of conventional and novel smart materials in the pretreatment and preconcentration of samples previous to IMS determinations has been critically reviewed. The most relevant strategies to enhance selectivity and sensitivity of IMS determinations have been widely discussed, based in the use of smart materials, as immunosorbents, aptamers, molecularly imprinted polymers (MIPs), ionic liquids (ILs) and nanomaterial. …
Comparative modelling study on enantioresolution of structurally unrelated compounds with amylose-based chiral stationary phases in reversed phase li…
2020
[EN] Polysaccharide-based chiral stationary phases (CSPs) are the most used chiral selectors in HPLC. These CSPs can be used in normal, polar organic and aqueous-organic mobile phases. However, normal and polar organic mobile phases are not adequate for chiral separation of polar compounds, for the analysis of aqueous samples and for MS detection. In these situations, reversed phase conditions, without the usual non-volatile additives incompatible with MS detection, are preferable. Moreover, in most of the reported chiral chromatographic methods, retention is too large for routine work. In this paper, the chiral separation of 53 structurally unrelated compounds is studied using three commer…
High-performance liquid chromatographic separation of modified and native melittin following transglutaminase-mediated derivatization with a dansyl f…
1991
Abstract The 26-amino acid linear, amphiphilic peptide melittin was enzymatically modified with the fluorescent probe monodansylcadaverine using guinea pig liver transglutaminase and a fluorescent derivative of stoichiometry 1:1 was obtained. Reversed-phase and size-exclusion high-performance liquid chromatographic modes were tested in order to resolve the labelled peptide and native species. The influence of several operational variables was analysed and the elution conditions were optimized so that a satisfactory resolution could be achieved in both instances in a rapid, easy manner. Both chromatographic modes offer the possibility of accurate monitoring of the time course of the enzyme-m…
Measurements of alveolar pO2 using 19F-MRI in partial liquid ventilation.
2003
Rationale and Objectives: Partial liquid ventilation using Perfluorcarbon (PFC) is an innovative treatment of acute respiratory distress syndrome. However, the underlying mechanisms are not totally clear. The aim was to investigate the distribution of oxygen partial pressure within the PFC-filled lung (ppO 2 ). Methods: Nine pigs underwent partial liquid ventilation, receiving 20 mL PFC/kg bodyweight (bw). Measurements were obtained by a chemical shift selective TurboFLASH sequence at different axial lung levels. ppO 2 was calculated from 1 9 F-MRI by nonlinear curve T 1 -fitting technique after noise correction. Results: Quantification and distribution of ppO 2 was performed successfully. …
Responsabilité du dirigeant et faute séparable des fonctions
2017
International audience; Note sous Cour de cassation (com.), 5 juillet 2017, n° 15-22.707 (F-D), G.
Annihilation at rest of antiprotons and protons into neutral particles
2003
Abstract Annihilation of antiprotons and protons at rest into neutral particles has been studied with the Crystal Barrel detector at LEAR. Annihilation frequencies are determined for final states containing π 0 , η , η ′ and ω mesons using a liquid and a room temperature, 12 bar, gaseous hydrogen target. Including annihilation frequencies for production of neutral kaons from other experiments, the identified reactions for annihilation in liquid hydrogen add up to a branching fraction of (3.56±0.28)% per annihilation compared to the frequency of (3.50±0.30)% with which we observe the all-neutral decay modes inclusively. Since the exclusive final states are normalized to the Crystal Barrel me…