0000000000013719

AUTHOR

Yolanda Moliner-martínez

Peptide Metal–Organic Frameworks for Enantioselective Separation of Chiral Drugs

We report the ability of a chiral Cu(II) 3D MOF based on the tripeptide Gly-L-His-Gly (GHG) for the enantioselective separation of metamphetamine and ephedrine. Monte Carlo simulations suggest that chiral recognition is linked to preferential binding of one of the enantiomers as result of either stronger or additional H-bonds with the framework that lead to energetically more stable diastereomeric adducts. Solid phase extraction (SPE) of a racemic mixture by using Cu(GHG) as extractive phase permits isolating more than 50% of the (+)-ephedrine enantiomer as target compound in only four minutes. To the best of our knowledge, this represents the first example of a MOF capable of separating ch…

research product

Miniaturized liquid chromatography coupled on-line to in-tube solid-phase microextraction for characterization of metallic nanoparticles using plasmonic measurements. A tutorial.

Abstract This tutorial aims at providing guidelines for analyzing metallic nanoparticles (NPs) and their dispersions by using methods based on miniaturized liquid chromatography with diode array detection (MinLC-DAD) and coupled on-line to in-tube solid-phase microextraction (IT-SPME). Some practical advice and considerations are given for obtaining reliable results. In addition, this work outlines the potential applications that set these methodologies apart from microscopy-related techniques, dynamic light scattering, single particle ICP-MS, capillary electrophoresis, field-flow fractionation and other chromatographic configurations, which are discussed and mainly seek to accomplish size …

research product

In Situ Colorimetric Quantification of Silver Cations in the Presence of Silver Nanoparticles

Silver ions (Ag(+)) can be quantified in situ in the presence of AgNPs by using a colorimetric sensing probe (3,3',5,5'-tetramethylbenzidine). Interestingly, it also enables detection of the Ag(+) adsorbed on the AgNP surface. This is relevant to design new methods to make AgNPs while ensuring the total reduction of Ag(+).

research product

Fast blue B functionalized silica-polymer composite to evaluate 3,5-dihy-droxyhydrocinnamic acid as biomarker of gluten intake

Celiac disease is an immune-mediated systemic disorder elicited by gluten and related prolamines in genetically susceptible individuals. The current treatment is a strict and lifelong gluten-free diet. However, compliance with the gluten-free diet is not always adequate and many food products contain low concentrations of gluten. The determination of dietary transgressions is a challenge for patients, physicians and dietitians. Alkylresorcinols (AR) have been proposed as sensitive and specific biomarkers of gluten consumption. In this work silica-polymer composites doped with fast blue B reagent (FB) have been used to estimate alkylresorcinols in biological samples. The proposed colorimetri…

research product

Adsorbent phases with nanomaterials for in-tube solid-phase microextraction coupled on-line to liquid nanochromatography

Following the present trends in miniaturization, a methodology that combines on-line In-Tube Solid-Phase Microextraction (IT-SPME) with Liquid Nanochromatography (nano-LC) and UV-vis diode array detection (DAD) was developed. This coupling was achieved by using two interconnected valves (i.e. conventional and micro-automatic valves) in the system of injection. As for IT-SPME, different materials, containing in some cases nanostructures or nanoparticles and in other cases polymeric adsorbent phases immobilized on capillary columns, were tested in order to improve extraction efficiencies of organic compounds; diclofenac was selected as the target analyte. Additionally, the transfer time of th…

research product

A sustainable on-line CapLC method for quantifying antifouling agents like irgarol-1051 and diuron in water samples: Estimation of the carbon footprint

In this work, in-tube solid phase microextraction (in-tube SPME) coupled to capillary LC (CapLC) with diode array detection has been reported, for on-line extraction and enrichment of booster biocides (irgarol-1051 and diuron) included in Water Frame Directive 2013/39/UE (WFD). The analytical performance has been successfully demonstrated. Furthermore, in the present work, the environmental friendliness of the procedure has been quantified by means of the implementation of the carbon footprint calculation of the analytical procedure and the comparison with other methodologies previously reported. Under the optimum conditions, the method presents good linearity over the range assayed, 0.05-1…

research product

A direct Capillary Liquid Chromatography with electrochemical detection method for determination of phenols in water samples

A fast and direct method based on the use of Capillary Liquid Chromatography (LC) with electrochemical (EC) detection has been described for phenols pollutants in water samples. Concretely, phenol, o-cresol, 2-chlorophenol and bisphenol A have been selected as target analytes. The combination of Capillary LC with EC detection avoided the necessity of preconcentration steps typically used in environmental analysis. The sample injected volume was 2 μL. The achieved detection limits were between 1 and 2 μg/L and the linear dynamic range was up to 50 μg/L for all studied phenols. The precision and uncertainty were satisfactory. The analysis time per sample was 10 min. The proposed procedure has…

research product

New Tools for Characterizing Metallic Nanoparticles: AgNPs, A Case Study.

Currently, transmission electron microscopy (TEM) is the main technique for estimating the sizes of spherical nanoparticles (NPs) and through them, their concentrations. This paper demonstrates for the first time that C18 reversed-phase capillary liquid chromatography (Cap-LC) coupled to diode array detection (DAD) has the potential to estimate mean concentrations of silver nanoparticles (AgNPs) and thereby determine their average size. Direct injection of the sample without previous extraction or separation steps is carried out. Only a unique standard with a known AgNP size is needed for the calibration. In a first approach, the new method has been tested over silver nanoparticles, produce…

research product

In tube-solid phase microextraction-nano liquid chromatography: Application to the determination of intact and degraded polar triazines in waters and recovered struvite.

Abstract In-tube solid-phase microextraction (IT-SPME) coupled to miniaturized liquid chromatography (LC) techniques are attractive mainly due to the column efficiency improvement, sensitivity enhancement and reduction of solvent consumption. In addition, the nanomaterials based sorbents can play a key role in the improvement of the extraction efficiency taking into account their interesting physical and chemical properties. Thus, in this work the performance of IT-SPME coupled to nano LC (NanoLC) has been compared with the performance of IT-SPME coupled to capillary LC (CapLC) with similar configurations for the determination of polar triazines including their degradation products. In both…

research product

NQS-Doped PDMS Solid Sensor: From Water Matrix to Urine Enzymatic Application

The development of in situ analytical devices has gained outstanding scientific interest. A solid sensing membrane composed of 1,2-naphthoquinone-4-sulfonate (NQS) derivatizing reagent embedded into a polymeric polydimethylsiloxane (PDMS) composite was proposed for in situ ammonium (NH4+) and urea (NH2CONH2) analysis in water and urine samples, respectively. Satisfactory strategies were also applied for urease-catalyzed hydrolysis of urea, either in solution or glass-supported urease immobilization. Using diffuse reflectance measurements combined with digital image processing of color intensity (RGB coordinates), qualitative and quantitative analyte detection was assessed after the colorime…

research product

Selective and sentivive method based on capillary liquid chromatography with in-tube solid phase microextraction for determination of monochloramine in water

Abstract Due to the difficulties of working with chloramines, a critical examination of monochloramine standard preparation has been performed in order to select the best synthesis conditions. The analyte has been determined by in-tube solid phase extraction coupled to capillary liquid chromatography with UV detection (IT-SPME Capillary LC DAD). Potential factors affecting the response of monochloramine such as the pH of mobile phase and the volume of sample processed by IT-SPME Capillary LC DAD have been investigated and optimized. According to the results of the study, 0.1 mL or 4.0 mL of sample at neutral pH were loaded in the chromatographic system. A sensitive and selective method has …

research product

Ionic-liquid doped polymeric composite as passive colorimetric sensor for meat freshness as a use case.

Abstract A composite membrane containing 1,2-naphthoquinone-4-sulfonic acid sodium salt (NQS) embedded in an ionic liquid (IL)- polydimethylsiloxane (PDMS)- tetraethyl orthosilicate (TEOS)- SiO2 nanoparticles (NPs) polymeric matrix is proposed. The selected IL was 1-methyl-3-octylimidazolium hexafluorophosphate (OMIM PF6). It is demonstrated that ILs chemical additives of PDMS influenced the sol-gel porosity. The sensor analytical performance for ammonia atmospheres has been tested as a function of sampling time (between 0.5 and 312 h), temperature (25 °C and 4 °C) and sampling volume (between 2L and 22 mL) by means of diffuse reflectance measurements and sensor photos, which can be registe…

research product

Improving analysis of apolar organic compounds by the use of a capillary titania-based column: Application to the direct determination of faecal sterols cholesterol and coprostanol in wastewater samples.

This article reports a new procedure for the direct determination of faecal sterols coprostanol and cholesterol in wastewater samples as tracers of human sewage contamination. The method combines in-tube solid-phase microextraction (IT-SPME) for analyte enrichment and capillary liquid chromatography (LC) for separation with diode array detection for identification and quantification. A titania-based polymeric capillary column and a conventional octadecyl silica (ODS) capillary column were evaluated and compared for their ability to separate the analytes. The titania-based column allowed the separation of the analytes in much shorter chromatographic times and with better chromatographic prof…

research product

Preconcentration of emerging contaminants in environmental water samples by using silica supported Fe3O4 magnetic nanoparticles for improving mass detection in capillary liquid chromatography

A magnetic material based on Fe(3)O(4) magnetic nanoparticles incorporated in a silica matrix by using a sol-gel procedure has been used to extract and preconcentrate emerging contaminants such as acetylsalicylic acid, acetaminophen, diclofenac and ibuprofen from environmental water samples prior to the analysis with Capillary LC-MS. The use of the proposed silica supported Fe(3)O(4) magnetic nanoparticles enables surfactant free extracts for the analysis with MS detection without interferences in the ionisation step. Under the optimum conditions, we demonstrated the reusability of the magnetic sorbent material during 20 uses without loss in the extraction efficiency. In addition, no cleanu…

research product

Guidelines for alkylphenols estimation as alkylphenol polyethoxylates pollution indicator in wastewater treatment plant effluents

A solid-phase microextraction coupled with a gas chromatography-mass spectrometry method has been developed for the estimation of technical nonylphenol in the presence of other endocrine disruptors, belonging to different chemical families. The profile of the technical nonylphenol found in real samples was tested, and, given that it was similar to that provided for the standard used, reliable results were obtainable. Endocrine disruptors such as 4-n-nonylphenol, bisphenol A and 4-tert-octylphenol were simultaneously analysed. The best conditions achieved enabled the analysis of all analytes using a sample volume of 15 mL or even only 300 μL. Using such a low sample volume reduced the filtra…

research product

Determination of meropenem in endotracheal tubes by in-tube solid phase microextraction coupled to capillary liquid chromatography with diode array detection.

Meropenem is a widely used antimicrobial for the treatment of infections associated with the use of invasive medical devices in intensive care unit patients. These treatments are not always effective, in fact, in-vitro studies have demonstrated the difficulty of antimicrobials to penetrate into the biofilm, however in-vivo studies of the effect of these compounds is a trend, mostly because of the complexity of pulmonary samples extracted from ETTs. Therefore, the objective of this study was to evaluate in-tube solid phase microextraction (in-tube SPME) coupled to capillary liquid chromatography (CapLC) with DAD to determine meropenem in Errs in order to estimate the penetration capability i…

research product

Trends in Online Intube Solid Phase Microextraction

research product

Cleaning sorbents used in matrix solid-phase dispersion with sonication: Application to the estimation of polycyclic aromatic hydrocarbons at ng/g levels in marine sediments

This study shows that ultrasonic assisted extraction is a good practise for removing impurities from sorbents used for matrix-solid phase dispersion (MSPD). A previous washing of the sorbent with an organic solvent or mixture of solvents eliminates part of the interferences, but this treatment is not enough for the quantification of PAHs at ng/g levels. It is demonstrated that the determination of traces of polycyclic aromatic hydrocarbons (PAHs) in solid samples processed by matrix-solid phase dispersion (MSPD) may be severely affected by the presence of sorbent impurities. Different extraction solvents and sonication conditions have been tested, and on the basis of the results obtained a …

research product

A solid device based on doped hybrid composites for controlling the dosage of the biocide N-(3-aminopropyl)-N-dodecyl-1,3-propanediamine in industrial formulations

A colorimetric composite device is proposed to determine the widely used biocide N-(3-aminopropyl)-N-dodecyl-1,3-propanediamine (ADP).This sensing device is based on a film of 1,2-Naphthoquinone-4-sulfonate (NQS) embedded into polydimethylsiloxane-tetraethylortosilicate-SiO2 nanoparticles composite (PDMS-TEOS-SiO2NPs). Semiquantitative analysis can be performed by visual inspection. Digitalized image or diffuse reflectance (DR) measurements can be carried out for quantitative analysis. Satisfactory detection limit (0.018%, w/v) and relative standard deviations <12% were achieved. The proposed device has been applied for the determination of ADP in detergent industrial formulations with reco…

research product

Characterization and Quantitation of Carbon Black Nanomaterials in Polymeric and Biological Aqueous Dispersants by Asymmetrical Flow Field Flow Fractionation

Characterization of carbon black (CB) nanomaterials is required in industrial and research areas. Hence, in this study, asymmetrical flow field flow fractionation coupled to UV–vis and DLS detectors in series (AF4-UV–vis-DLS) was studied to evaluate the CB dispersion behavior in polymeric and biological dispersants, given the relevance of these media in practical applications. Under the experimental conditions, the results indicated that polymeric and biological dispersions showed size distributions with hydrodynamic diameters of 404 and 175 nm, respectively, for a particle core diameter of 40 nm. The polymeric dispersant provided lower stability as a function of time than that achieved by …

research product

Development of a polydimethylsiloxane–thymol/nitroprusside composite based sensor involving thymol derivatization for ammonium monitoring in water samples

This report describes a polydimethylsiloxane (PDMS)-thymol/nitroprusside delivery composite sensor for direct monitoring of ammonium in environmental water samples. The sensor is based on a PDMS support that contains the Berthelot's reaction reagents. To prepare the PDMS-thymol/nitroprusside composite discs, thymol and nitroprusside have been encapsulated in the PDMS matrix, forming a reagent release support which significantly simplifies the analytical measurements, since it avoids the need to prepare derivatizing reagents and sample handling is reduced to the sampling step. When, the PDMS-thymol/nitroprusside composite was introduced in water samples spontaneous release of the chromophore…

research product

Advantages of monolithic over particulate columns for multiresidue analysis of organic pollutants by in-tube solid-phase microextraction coupled to capillary liquid chromatography

Abstract The performance of a monolithic C 18 column (150 mm × 0.2 mm i.d.) for multiresidue organic pollutants analysis by in-tube solid-phase microextraction (IT-SPME)-capillary liquid chromatography has been studied, and the results have been compared with those obtained using a particulate C 18 column (150 mm × 0.5 mm i.d., 5 μm). Chromatographic separation has been carried out under isocratic elution conditions, and for detection and identification of the analytes a UV-diode array detector has been employed. Several compounds of different chemical structure and hydrophobicity have been used as model compounds: simazine, atrazine and terbutylazine (triazines), chlorfenvinphos and chlorp…

research product

Quantitative study of the capture of silver nanoparticles by several kinds of soils

The capacity of different soils to capture silver nanoparticles (AgNPs) by measuring changes of an AgNP intrinsic property such as the plasmon for the first time, was studied. In-tube solid-phase microextraction (IT-SPME) coupled on-line to capillary liquid chromatography (CapLC) with diode array detection (DAD) was employed for measuring the interactions between soil and in-contact AgNP dispersions. Its achieved LOD 9 pM assures quantitative retention measurements and selectivity for soil lixiviation was suitable. Electronic microscopy was employed for corroborating the entrapped Ag into the soils. Capture % of AgNPs was calculated in compost (>99%), mountain (>99%), orchard (15±1%) and ur…

research product

Solid glucose biosensor integrated in a multi-well microplate coupled to a camera-based detector: Application to the multiple analysis of human serum samples

Abstract In the present work, a biosensor adapted in a 96-well microplate has been coupled with a smartphone-based photometer in order to develop a low-cost colorimetric multi-sample dispositive. The strength of this biosensing system is based on the integration of the biosensor into the 96-well microplate and the use of a smartphone and free image analysis software as a microplate reader. The performance of the proposed biosensor has been demonstrated to determine glucose in several human serum samples. This method is simple, cost-effective, sensitive and selective for the determination of glucose in serum, with detection limits of 1.8 mg/dL and a good linearity over the range 6–88 mg/dL. …

research product

Colorimetic biosensing dispositive based on reagentless hybrid biocomposite: Application to hydrogen peroxide determination

Abstract An efficient approach to enhance the performance of colorimetric biosensors has been developed. The biosensor is based on the co-immobilization of the reagent 3,3′,5,5′-teramethylbencidine (TMB) and the enzyme horseradish peroxidase (HRP) in a PDMS-TEOS-SiO2NPs support. The HRP, in presence of H2O2, catalyzes the oxidation of TMB, producing a blue color. The generated biosensor, doped with the substrate (TMB) and the enzyme (HRP) (entrapped or adsorbed), has been used to determine H2O2 in real samples. Firstly, the immobilization of TMB and HRP in the composite has been studied in order to find the best suitable configuration. The kinetic parameters Vmax (maximum reaction rate) and…

research product

Aqueous Dilution of Noble NPs Bulk Dispersions: Modeling Instability due to Dissolution by AF4 and Stablishing Considerations for Plasmonic Assays

Among different nanomaterials, gold and silver nanoparticles (AuNPs and AgNPs) have become useful tools for a wide variety of applications in general, and particularly for plasmonic assays. Particle size and stability analysis are key elements for their practical applications since the NPs properties depend on these parameters. Hence, in the present work, asymmetrical flow field flow fractionation (AF4) coupled to UV-Vis and dynamic light scattering (DLS) detectors in series, has been evaluated for stability studies of citrate-capped AuNPs and AgNPs aqueous dispersions. First, experimental parameters, such as mobile phase or cross-flow rate were optimized. Sodium azide to pH 7 for AuNPs and…

research product

A method for the determination of dimethylamine in air by collection on solid support sorbent with subsequent derivatization and spectrophotometric analysis.

A new method for dimethylamine determination in air is reported. The proposed assay is based on the employment of C18-packed solid phase extraction cartridges for sampling. The retained amine is then derivatized inside the cartridges with the reagent 1,2-naphthoquinone-4-sulfonate. By observing the coloured area of the cartridge, a semiquantitative estimation of the amine can be made. It was also possible to distinguish between primary and secondary amines by visual inspection. Quantitative tests entailed desorption from the cartridges of the derivatives formed, and measurement of the absorbance of the collected extracts. The selected conditions were applied to quantify dimethylamine up to …

research product

A cost-effective method for estimating di(2-ethylhexyl)phthalate in coastal sediments.

This study describes the development of a new method for the analysis of di(2-ethylhexyl)phthalate (DEHP) using 0.1-0.3 g of sediment sample, based on matrix solid phase dispersion (MSPD) using C18 as dispersant phase (0.4 g) and acetonitrile-water as eluting solvent (3.4 mL 1:3.25, v/v). No evaporation step is required. 3 mL of extracts were processed on-line by in-tube solid phase microextraction (IT-SPME) coupled to capillary liquid chromatography (CapLC) and diode array detector (DAD). A short analytical column Zorbax SB C18 (35×0.5 mm, 5 μm) provided suitable results. FTIR-ATR was employed for characterizing sediment samples and MSPD procedure. The total analysis time was less than 20 …

research product

Influence of water sample storage protocols in chemiluminescence detection of trace elements.

This paper shows the influence of different sample storage protocols, on the chemiluminescence signal of some metal ions. The storage protocols studied were: acid addition (HCl or HNO(3)) and no reagent addition to filtered and refrigerated (T=4 degrees C) samples. Light emission was produced for the chemiluminescence reaction between luminol and hydrogen peroxide in buffer carbonate conditions (pH 10.8) catalysed by Cr(III), Co(II) and Cu(II). Batch and/or flow modes in different conditions were tested. Fe(II), Fe(III), Ni(II) and Mn(II) did not give chemiluminescence in the studied conditions. A parallel study of sensitivity and selectivity was performed. Then the presence or absence of t…

research product

The impact of a disused mine on uranium transport in the River Fal, South West England.

Unfiltered and filtered (0.45 and 0.2 microm) water samples and sediment samples (sieved to180 microm and 180-1000 microm) were collected along an approximately 15 km transect of the River Fal, Cornwall, UK, to examine the impact of the disused South Terras uranium mine on the uranium concentrations of the river water and underlying sediments. The uranium concentration of the water samples fluctuated along the river, with the 0.45 microm filtered water showing the largest, seven-fold, difference between minimum (0.19 microg L(-1)) and maximum (1.34 microg L(-1)) concentrations. The historical uranium mine and spoil heaps were not a significant source of uranium to the river water, as water …

research product

Microextraction with phases containing nanoparticles.

In this article, the state of the art of microextraction techniques that involve nanoparticles or nanomaterials (NPs) is reviewed, with special emphasis on the applications described in the biomedical field. The uses and advantages of the different types of NPs such as carbon nanotubes (either single- and multi-walled) and other carbon-based materials, metallic NPs, including gold, silver and magnetic NPs, and silica NPs are summarized. The main strategies used to modify the selectivity, extractive capacity and/or the stability of NPs through a chemical reaction are also reviewed. The potential advantages of NPs in different forms of off-line and on-line microextraction are discussed, and …

research product

An in-tube SPME device for the selective determination of chlorophyll a in aquatic systems.

We report a new device for the estimation of the content of chlorophyll a pigment in water samples as an indicator of water quality. The extraction of the pigment from water was also optimized. 10 mL of water was filtered through a nylon filter (45m pore size and 13 mm of diameter), after the chlorophylls were dissolved by immersing the filter in 1 mL of a low non-hazardous solvent as ethanol. An in-valve in-tube SPME device coupled to capillary liquid chromatography with diode array detection was designed. A capillary column of 70 cm in length (0.32 mm i.d. coated with 5% diphenyl–95% polydimethylsiloxane, 3m coating thickness) was used as the loop of the injection valve for preconcentrati…

research product

A microanalytical method for ammonium and short-chain primary aliphatic amines using precolumn derivatization and capillary liquid chromatography.

Abstract A new microscale method is presented for the determination of ammonium and primary short-chain aliphatic amines (methylamine, ethylamine, propylamine, n -butylamine and n -pentylamine) in water. The assay uses precolumn derivatization with the reagent o -phthaldialdehyde (OPA) in combination with the thiol N -acetyl- l -cysteine (NAC), and capillary liquid chromatography with UV detection at 330 nm. The described method is very simple and rapid as no preconcentration of the analytes is necessary, and the volume of sample required is only 0.1 mL. Under the proposed conditions good linearity has been obtained up to a concentration of the analytes of 10.0 mg L −1 , the limits of detec…

research product

More about sampling and estimation of mercaptans in air samples

[EN] Several strategies have been developed for sampling and determination of volatile thiols. The selectivity and sensitivity of the proposed methodologies are achieved by using a specific derivatizing reagent. The different procedures assayed are based on air sampling followed by derivatization of the analytes with OPA and isoleucine in alkaline solution. The derivatization products are separated and determined by liquid chromatography and fluorescence detection. To start, the derivatization conditions and stability of the derivates have been studied in order to establish the storage conditions. In general, the strategies studied consisted on trapping and detivatization the thiol compound…

research product

Detector supports: application to aliphatic amines in wastewater

Abstract Solid support assisted derivatization coupled to diffuse reflectance spectroscopy (DRS) was proposed and proved useful for the detection and quantification of aliphatic amines in water as an example. Dabsyl chloride (DBS), ninhydrin and sodium 1,2-naphtoquinone 4-sulphonate (NQS) were assayed as derivatization reagents. C 18 and SDB-XC disks and C 18 cartridges were tested for amine retention and after that derivatization. The decrease of the orange colour of dabsyl chloride on SBD-XC disks produced by the formation of its derivative with methylamine in the support (10 min at 100 °C) allowed the selective determination of the amine at concentration level equal or higher than 0.5 mg…

research product

Designing solid optical sensors for in situ passive discrimination of volatile amines based on a new one-step hydrophilic PDMS preparation

Abstract We reported an optimal material for embedding chemoresponsive dyes based on modified commercial PDMS. A new approach to impart hydrophilicity to H-PDMS in an unique step was developed by addition of tetraethyl orthosilicate (TEOS) and in absence of basic or acid aqueous mixtures or hydroxyl-compounds during the PDMS coating process. This incorporation significantly enhances the performance of PDMS-based devices for sensing applications. New colorimetric sensors for passive detection and in situ discrimination of volatile amines have been obtained. The limit of detection achieved was 1.5 mg m −3 for both, dimethylamine and methylamine, suitable to control real working atmospheres. T…

research product

A miniaturized method for estimating di(2-ethylhexyl) phthalate in bivalves as bioindicators.

This work has developed a miniaturized method based on matrix solid phase dispersion (MSPD), using C18 as dispersant and acetonitrile-water as eluting solvent, for the analysis of di(2-ethylhexyl) phthalate (DEHP) in biota samples by capillary liquid chromatography coupled to in-tube solid phase microextraction and diode array detection. Recovery studies showed that the combination of C18-Florisil® was optimal using low amount of samples (0.1 g) and with low volumes of acetonitrile-water (2.6 mL 1:3.25, v/v). The sample is processed in less than 30 min, no evaporation step is required. The proposed method was applied to the analysis of DEHP in mussels and of the coastal waters in which they…

research product

In-tube solid phase microextraction coupled to miniaturized liquid chromatography for both, noble metal nanoparticle assessment and sensitive plasmonic assay development.

Abstract Colorimetric localized surface plasmon resonance (LSPR) as analytical response is applied for a wide number of chemical sensors and biosensors. However, the dependence of different factors, such as size distribution of nanoparticles (NPs), shape, dielectric environment, inter-particle distance and matrix, among others, can provide non-reliable results by UV–vis spectrometry in complex matrices if NP assessment is not carried out, particularly at low levels of analyte concentrations. Miniaturized liquid chromatography, capillary (CapLC) and nano (NanoLC), coupled on line with in-tube solid phase microextraction (IT-SPME) is proposed for the first time for both, controlling suitabili…

research product

Ion-pair in-tube solid-phase microextraction and capillary liquid chromatography using a titania-based column: application to the specific lauralkonium chloride determination in water.

Abstract A quick, miniaturized and on-line method has been developed for the determination in water of the predominant homologue of benzalkonium chloride, dodecyl dimethyl benzyl ammonium chloride or lauralkonium chloride (C 12 -BAK). The method is based on the formation of an ion-pair in both in-tube solid-phase microextraction (IT-SPME) and capillary liquid chromatography. The IT-SPME optimization required the study of the length and nature of the stationary phase of capillary and the processed sample volume. Because to the surfactant character of the analyte both, the extracting and replacing solvents, have played a decisive role in the IT-SPME optimized procedure. Conditioning the capil…

research product

In-tube solid-phase microextraction coupled by in valve mode to capillary LC-DAD: Improving detectability to multiresidue organic pollutants analysis in several whole waters

Abstract A simple and fast capillary chromatographic method has been developed to identify and quantify organic pollutants at sub-ppb levels in real water samples. The major groups of pesticides (organic halogens, organic phosphorous, and organic nitrogen compounds), some hydrocarbons (polycyclic aromatic hydrocarbons), phthalates and some phenols such as phenol and bisphenol A (endocrine disruptors) were included in this study. The procedure was based on coupling, in-tube solid-phase microextraction (IT-SPME) by using a conventional GC capillary column (95% methyl–5% phenyl substituted backbone, 80 cm × 0.32 mm i.d., 3 μm film thickness) in the injection valve to capillary liquid chromatog…

research product

Polydimethylsiloxane composites containing 1,2-naphtoquinone 4-sulphonate as unique dispositive for estimation of casein in effluents from dairy industries.

A unique dispositive to determine casein which is the most abundant protein in dairy sewages has been proposed. In this sensing technology, the derivatization reagent 1,2-naphtoquininone 4-sulphonate (NQS) is embedded into a polydimethylsiloxane-tetraethylortosilicate-SiO2 nanoparticles composite (PDMS-TEOS-SiO2NPs). When the composite is immersed into the samples, casein is extracted from the solution and derivatized inside the PDMS matrix after 10 min at 100°C. The sensing support changes its color from yellow to orange depending on the casein concentration. Quantitative analysis can be carried out by measuring the absorbance with a reflection probe or by image-processing tool (GIMP). Thi…

research product

Study of the influence of temperature and precipitations on the levels of BTEX in natural waters.

Assessment of seasonal changes in surface water quality is an important aspect for evaluating temporal variation of water due to natural or anthropogenic inputs of point and non-point sources. The objective of this paper was to investigate the influence of seasonal temperature fluctuations and precipitations on the levels of BTEX in natural waters. Principal component analysis (PCA) was used to evaluate the seasonal correlations of BTEX levels in water and to extract the parameters that are most important in assessing seasonal variations of water quality. This study was carried out as a part of VOCs monitoring program in natural water samples from Mediterranean coast. To carry out this proj…

research product

Sensitive and selective plasmonic assay for spermine as biomarker in human urine.

A simple, fast, and highly selective and sensitive colorimetric assay to detect nanomolar levels of spermine in human urine (healthy donors, cancer patients) is reported. This assay is based on the absence of a competitive organic capping on the gold nanoparticles together with the high affinity of the amine groups of the analyte for the nanoparticle surface.

research product

Multiresidue analysis of organic pollutants by in-tube solid phase microextraction coupled to ultra-high performance liquid chromatography-electrospray-tandem mass spectrometry.

In this work, in-tube solid phase microextraction (IT-SPME) coupling with ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) multiresidue analytical method has been proposed for the first time for on-line enrichment of 9 analytes included in Water Frame Directive 2000/60/EC (WFD). The device was equipped with a GC TRB-5 capillary column, used as pre-concentration loop, and two conventional six-port injection valves. Water sample and desorption solvent volumes were tested. The optimum conditions were 4mL of processed sample followed by elution with 40μL of methanol. The analytes were detected with a mass spectrometer after being ionized positively using an elect…

research product

Combining poly(dimethyldiphenylsiloxane) and nitrile phases for improving the separation and quantitation of benzalkonium chloride homologues: In-tube solid phase microextraction-capillary liquid chromatography-diode array detection-mass spectrometry for analyzing industrial samples.

The retention and separation of four homologues of benzalkonium chloride (alkyl (C12, C14, C16, C18) dimethylbenzylammonium chloride) have been studied in poly(dimethyldiphenylsiloxane) (TRB) and nitrile capillary phases, respectively. Under the optimized conditions (50% acetonitrile in processed samples, 35% of diphenyl content of the TRB, capillary length 43 cm and water:methanol 60:40 as replacing solvent), the extraction efficiency was similar for all the homologues with satisfactory reproducibility and independently of the amount and proportion of homologues. Industrial samples with high viscosity or with complex composition and washes waters have been analyzed without previous treatme…

research product

Determination of amphetamines in hair by integrating sample disruption, clean-up and solid phase derivatization

The utility of matrix solid phase dispersion (MSPD) for the direct analysis of amphetamines in hair samples has been evaluated, using liquid chromatography (LC) with fluorescence detection and precolumn derivatization. The proposed approach is based on the employment of MSPD for matrix disruption and clean-up, followed by the derivatization of the analytes onto the dispersant-sample blend. The fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC) has been used for derivatization. Different conditions for MSPD, analyte purification and solid phase derivatization have been tested, using amphetamine (AMP), methamphetamine (MET), ephedrine (EPE) and 3,4-methylenedioxymethamphetamine (MDMA)…

research product

Disinfection by-products effect on swimmers oxidative stress and respiratory damage.

Disinfection by-products (DBPs) are generated through the reaction of chlorine with organic and inorganic matter in indoor swimming pools. Different DBPs are present in indoor swimming pools. This study evaluated the effects of different chlorinated formations in oxidative stress and lung damage in 20 swimmers after 40 min of aerobic swimming in 3 indoor pools with different characteristics. Biological samples were collected to measure lung damage (serum-surfactant-associated proteins A and B), oxidative stress parameters (plasma protein carbonylation and malondialdehyde, and whole-blood glutathione oxidation), and swimming exertion values (blood lactate) before and after exercise. Free chl…

research product

Analysis of 18 perfluorinated compounds in river waters: Comparison of high performance liquid chromatography–tandem mass spectrometry, ultra-high-performance liquid chromatography–tandem mass spectrometry and capillary liquid chromatography–mass spectrometry

In this work, the performance of ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) and capillary liquid chromatography-mass spectrometry (CLC-MS) has been studied for the analysis of eighteen perfluorinated compounds in water samples. UHPLC-MS/MS and CLC-MS analysis were carried out using a Zorbax C-18 column (50 mm × 2.1 mm, 1.8 μm) and a Zorbax SB-C18 column (150 mm × 0.5 mm, 3.5 μm), respectively, in gradient elution mode with a mobile phase of ammonium formate and methanol. Both techniques were compared with conventional LC-MS/MS in terms of speed, sensitivity, selectivity and resolution. Water samples were extracted by solid phase extraction (SPE). Mea…

research product

On-line in-tube solid phase microextraction-capillary liquid chromatography method for monitoring degradation products of di-(2-ethylhexyl) phthalate in waters

Abstract The main di-(2-ethylhexyl) phthalate (DEHP) degradation products, (2-ethylhexyl) phthalate (MEHP), diethyl phthalate (DEP) and dibutyl phthalate (DBP), have been tested. The proposed cost-effective method combines on-line, in-tube solid-phase micro extraction (IT-SPME) in in-valve configuration and capillary liquid chromatography with UV diode array detection (Cap-LC-DAD). Acidification of the samples at pH 3 improved markedly the estimation of MEHP. Aliquots of 4 mL of acidified water samples were directly processed. After sample loading, the analytes were desorbed with the mobile-phase and transferred to the monolithic capillary column. Satisfactory linearity and precision, absen…

research product

Solid-Phase Extraction and Clean-Up Procedures in Pharmaceutical Analysis

Solid-phase extraction (SPE) using small cartridges filled with sorbents of a small particle size has rapidly established itself as an important sample clean-up technique. It has prospered at the expense of liquid-liquid extraction (LLE), which is considered labor intensive and frequently plagued by problems, such as emulsion formation and use of large volumes of hazardous solvents. A remarkable characteristic of SPE is its easy adaptation to on-line mode by column-switching techniques; switching can be effected manually or by automated controllers. The same analyte/sorbent interactions that are exploited in liquid chromatography (LC) are of use in SPE, but particle sizes employed are great…

research product

Study of the Stability of Citrate Capped AgNPs in Several Environmental Water Matrices by Asymmetrical Flow Field Flow Fractionation

Asymmetrical flow field-flow fractionation (AF4) coupled to UV-Vis and dynamic light scattering (DLS) detectors in series, was tested for stability studies of dispersions of citrate-capped silver nanoparticles (AgNPs) in several water matrices. The main goal is to provide knowledge to understand their possible behavior in the environment for short times since mixturing (up to 180 min). Ultrapure (UPW), bottled (BW1, BW2), tap (TW), transitional (TrW) and sea water (SW) matrices were assayed. Observations were compatible with the aggregation of AgNPs, a change in the plasmon band and a size growth with time were done. Fractograms showed different evolution fingerprints in the function of the…

research product

Recent advances of in-tube solid-phase microextraction

Abstract In-tube solid-phase microextraction (SPME) is ideally suited to developing green extraction by combining miniaturization, automation and reduction of solvent consumption. SPME has been used for the analysis of environmental, biological, and food samples, and numerous works have shown the benefits of using SPME. However, for full development of in-tube SPME, effort is still needed to overcome limitations, such as low extraction efficiency, selectivity and mechanical stability. To achieve these objectives, research on in-tube SPME is mainly focused in two scenarios: (1) the coupling of in-tube SPME with new chromatographic modalities, such as miniaturized liquid chromatography; and, …

research product

Footprint of carbonyl compounds in hand scent by in-tube solid-phase microextraction coupled to nano-liquid chromatography/diode array detection

Abstract In the present work, the footprint of carbonyl compounds in hand scent was achieved by a miniaturized method consisting of sampling with cotton gauze, extraction and derivatization using 2,4-dinitrophenylhydrazine (DNPH) and preconcentration, separation and detection by in-tube solid-phase microextraction (IT-SPME) coupled to nano-liquid chromatography/Uv–vis diode array detection. The coupling IT-SPME-nanoLC-DAD was solved by using a two-valve system: the first valve for loading the sample and the second one to perform IT-SPME. To this aim, a nanoparticle-based capillary column was employed. Firstly, the transfer time from the load loop to the NP-based capillary column in the IT-S…

research product

Influence of the presence of surfactants and humic acid in waters on the indophenol-type reaction method for ammonium determination.

Abstract This work has evaluated the influence of humic acid and/or surfactants in the quantification of ammonium in waters with the indophenol-type reaction method. Thymol has been employed with the colorimetric method for sample ammonium concentrations between 0.25 and 1 mg L −1 . In addition, SPE/diffuse reflectance method has been used for quantification of ammonium at low concentrations (between 0.025 and 0.25 mg L −1 ). Matrix effect owing to humic substances were observed with the colorimetric method when the concentration was equal or higher than 25 mg L −1 . Lower concentrations of humic compounds produced matrix effects with the more sensitive SPE/diffuse reflectance method. Gener…

research product

Evaluation of Superparamagnetic Silica Nanoparticles for Extraction of Triazines in Magnetic in-Tube Solid Phase Microextraction Coupled to Capillary Liquid Chromatography

The use of magnetic nanomaterials for analytical applications has increased in the recent years. In particular, magnetic nanomaterials have shown great potential as adsorbent phase in several extraction procedures due to the significant advantages over the conventional methods. In the present work, the influence of magnetic forces over the extraction efficiency of triazines using superparamagnetic silica nanoparticles (NPs) in magnetic in tube solid phase microextraction (Magnetic-IT-SPME) coupled to CapLC has been evaluated. Atrazine, terbutylazine and simazine has been selected as target analytes. The superparamagnetic silica nanomaterial (SiO2-Fe3O4) deposited onto the surface of a capil…

research product

New optical paper sensor for in situ measurement of hydrogen sulphide in waters and atmospheres

A novel and low-cost colorimetric sensor for the determination of hydrogen sulphide in environmental samples has been developed. This sensor is based on the immobilization of the reagent N,N-Dimethyl-p-phenylenediamine and FeCl3 in paper support, in which the H2S is adsorbed in order to give rise to the formation of methylene blue as reaction product. The sensor has been applied to determine H2S in water and air samples. Two different sampling systems for H2S caption from the air have been assayed: active and passive sampling. The analytical properties of the different systems have been obtained and compared. The analytical signals, corresponding to the methylene blue, have been obtained me…

research product

Improved detection limit for ammonium/ammonia achieved by Berthelot's reaction by use of solid-phase extraction coupled to diffuse reflectance spectroscopy

Abstract The proposed procedure is based on the extraction of the indothylmol blue into C 18 solid-phase extraction (SPE) membranes and direct quantification on the membrane surface by diffuse reflectance spectroscopy. The analytical performance of the proposed method has been evaluated for standard solutions of ammonium using reflectance values, R , as well as the Kubelka–Munk function, F ( R ). The results have been compared with those obtained by the conventional method, which uses UV–vis absorption spectroscopy with a sensor-based method. The described methodology provided satisfactory linearity and reproducibility within the ammonium concentration intervals 25–250 μg L −1 and 25–500 μg…

research product

A guide for selecting the most appropriate method for ammonium determination in water analysis

Abstract We have critically evaluated the main parameters involved in determining ammonium in water samples, in order to select the most suitable method appropriate to the requirements of the analysis. We compared several methods: reference (ion-selective electrodes, Nessler and indophenol); Roth’s modified; based on luminol reaction; and, based on peroxioxalate reaction.

research product

Determination of carbonyl compounds in particulate matter PM2.5 by in-tube solid-phase microextraction coupled to capillary liquid chromatography/mass spectrometry.

Abstract In this paper, a new procedure based on in-tube solid phase microextraction (IT-SPME)-capillary liquid chromatography hyphenated to mass spectrometry detection by using microelectrospray ionisation (CapLC–MS), has been reported. The device was proposed to quantify 12 carbonyl compounds (10 aliphatic aldehydes, an unsaturated aldehyde and a ketone) derivatized with 2,4-dinitrophenylhidrazine (DNPH) reagent in aqueous extracts of PM 2.5 . This methodology involves the on-line preconcentration of DNPH-carbonyl compounds derivatives coupled to the CapLC–MS system, efficiently providing appropriate sensitivity for the determination of the target analytes. Detection limits for the analyt…

research product

Magnetic In-Tube Solid Phase Microextraction

We report a new in-tube solid phase microextraction approach named magnetic in-tube solid phase microextraction, magnetic-IT-SPME. Magnetic-IT-SPME has been developed, taking advantage of magnetic microfluidic principles with the aim to improve extraction efficiency of IT-SPME systems. First, a magnetic hybrid material formed by Fe(3)O(4) nanoparticles supported on SiO(2) was synthesized and immobilized in the surface of a bared fused silica capillary column to obtain a magnetic adsorbent extraction phase. The capillary column was placed inside a magnetic coil that allowed the application of a variable magnetic field. Acetylsalicylic acid, acetaminophen, atenolol, diclofenac, and ibuprofen …

research product

Miniaturized matrix solid phase dispersion procedure and solid phase microextraction for the analysis of organochlorinated pesticides and polybrominated diphenylethers in biota samples by gas chromatography electron capture detection

Abstract This work has developed a miniaturized method based on matrix solid phase dispersion (MSPD) using C18 as dispersant and acetonitrile–water as eluting solvent for the analysis of legislated organochlorinated pesticides (OCPs) and polybrominated diphenylethers (PBDEs) in biota samples by GC with electron capture (GC-ECD). The method has compared Florisil®-acidic Silica and C18 as dispersant for samples as well as different solvents. Recovery studies showed that the combination of C18–Florisil® was better when using low amount of samples (0.1 g) and with low volumes of acetonitrile–water (2.6 mL). The use of SPME for extracting the analytes from the solvent mixture before the injectio…

research product