Search results for "Biosensors"
showing 10 items of 41 documents
Inkjet printing arrays and their applications for drug screening
2010
Chromium inhibition and size-selected Au nanocluster catalysis for the solution growth of low-density ZnO nanowires.
2015
The wet chemical synthesis of nanostructures has many crucial advantages over high-temperature methods, including simplicity, low-cost, and deposition on almost arbitrary substrates. Nevertheless, the density-controlled solution growth of nanowires still remains a challenge, especially at the low densities (e.g. 1 to 10 nanowires/100 μm(2)) required, as an example, for intracellular analyses. Here, we demonstrate the solution-growth of ZnO nanowires using a thin chromium film as a nucleation inhibitor and Au size-selected nanoclusters (SSNCs) as catalytic particles for which the density and, in contrast with previous reports, size can be accurately controlled. Our results also provide evide…
Luminometric Sub-nanoliter Droplet-to-droplet Arrays (LUMDA-chip) for Drug Screening on Phase I Metabolism Enzymes
2013
Here we show the fabrication of the Luminometric Sub-nanoliter Droplet-to-droplet Array (LUMDA chip) by inkjet printing. The chip is easy to be implemented and allows for amultiplexed multi-step biochemical assay in sub-nanoliter liquid spots. This concept is here applied to the integral membrane enzyme CYP3A4, i.e. themost relevant enzymatic target for phase I drug metabolism, and to some structurally-related inhibitors.
A Review of Biosensors for Non-Invasive Diabetes Monitoring and Screening in Human Exhaled Breath
2019
Exhaled breath acetone has been identified as a diabetes biomarker for non-invasive diagnosis. Its detection using biosensors features has many advantages over the conventional means. This paper reviews the recent literature on the detection of exhaled breath acetone and acetone vapor of diabetic interest. The biosensors have been classified based on their transduction methods. The performance characteristics of the biosensors have been explored for comparison. The future trends are also highlighted.
Amperometric Biosensor and Front-End Electronics for Remote Glucose Monitoring by Crosslinked PEDOT-Glucose Oxidase
2018
Focusing on the interplay between interface chemistry, electrochemistry, and integrated electronics, we show a novel low-cost and flexible biosensing platform for continuous glucose monitoring. The amperometric biosensing system features a planar three-electrode structure on a plastic substrate, and a wireless near-field communication-powered electronic system performing sensor analog front-end, A/D conversion, digital control, and display tasks. The working electrode is made of electropolymerized poly (3,4-ethylenedioxythiophene) film onto a polyethylene terephthalate/gold electrode followed by immobilization of cross-linked glucose oxidase by glutaraldehyde. The advantages offered by such…
Integrated optic surface plasmon resonance measurements in a borosilicate glass substrate
2008
The surface plasmon resonance (SPR) technique is a well-known optical method that can be used to measure the refractive index of organic nano-layers adsorbed on a thin metal film. Although there are many configurations for measuring biomolecular interactions, SPR-based techniques play a central role in many current biosensing experiments, since they are the most suited for sensitive and quantitative kinetic measurements. Here we give some results from the analysis and numerical elaboration of SPR data from integrated optics experiments in a particular borosilicate glass, chosen for its composition offering the rather low refractive index of 1.4701 at 633 nm wavelength. These data regard the…
Characteristic ERK1/2 signaling dynamics distinguishes necroptosis from apoptosis
2021
International audience; ERK1/2 involvement in cell death remains unclear, although many studies have demonstrated the importance of ERK1/2 dynamics in determining cellular re- sponses. To untangle how ERK1/2 contributes to two cell death programs, we investigated ERK1/2 signaling dynamics during hFasL-induced apoptosis and TNF-induced necroptosis in L929 cells. We observed that ERK1/2 inhibition sensi- tizes cells to apoptosis while delaying necroptosis. By monitoring ERK1/2 activity by live-cell imaging using an improved ERK1/2 biosensor (EKAR4.0), we reported differential ERK1/2 signaling dynamics between cell survival, apoptosis, and nec- roptosis. We also decrypted a temporally shifted …
Novel Immune TiO2 Photoluminescence Biosensors for Leucosis Detection
2012
Abstract Novel immune photoluminescent biosensor, based on TiO2 nanoparticles, for retroviral leucosis detection has been developed. The photoluminescence spectra were excited by solid state laser with wavelength 355 nm and measured in the range of 370-800 nm. Original photoluminescence spectrum of TiO2 nanoparticles showed wide maximum at 515 nm. The biosensitive layer was formed by immobilization of retroviral leucosis antigens on the surface of TiO2 nanoparticles. Immobilization of antigens on TiO2 surface led to UV-shift of photoluminescence spectrum and increase of PL intensity. The response to different concentrations of retroviral leucosis antibodies has been measured. The decrease o…
Affinity Sensors for the Diagnosis of COVID-19
2021
The coronavirus disease 2019 (COVID-19) outbreak caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was proclaimed a global pandemic in March 2020. Reducing the dissemination rate, in particular by tracking the infected people and their contacts, is the main instrument against infection spreading. Therefore, the creation and implementation of fast, reliable and responsive methods suitable for the diagnosis of COVID-19 are required. These needs can be fulfilled using affinity sensors, which differ in applied detection methods and markers that are generating analytical signals. Recently, nucleic acid hybridization, antigen-antibody interaction, and change of reactive oxyge…
Label-free wavelength and phase detection based SMS fiber immunosensors optimized with cladding etching
2018
The performance of E-SMS (Etched Singlemode-Multimode-Singlemode) optical fiber structures as immunosensors has been assessed by the implementation of antibody/antigen immunoassays. Through this procedure it has been proven that E-SMS structures are effective and suitable optical platforms for label-free biosensing. Using the phase shift and tracking the wavelength response it was found that the fabricated E-SMS devices exhibited limits of detection (LOD) down up to concentrations of 0.2mg/L of antigens in solution. This was achieved by coating the E-SMS with an antibody-based biolayer (goat IgG) that is able to determine the presence of anti-goat IgG antigen. Both a wavelength detection an…