0000000000005669

AUTHOR

Balthasar Eberle

Successful treatment of a patient with ARDS after pneumonectomy using high-frequency oscillatory ventilation.

High frequency oscillatory ventilation (HFOV) was used in a patient who developed the acute respiratory distress syndrome 5 days following a right pneumonectomy for bronchogenic carcinoma. When conventional pressure-controlled ventilation failed to maintain adequate oxygenation, HFOV dramatically improved oxygenation within the first few hours of therapy. Pulmonary function and gas exchange recovered during a 10-day period of HFOV. No negative side effects were observed. Early use of HFOV may be a beneficial ventilation strategy for adults with acute pulmonary failure, even in the postoperative period after lung resection.

research product

Multirotations-CT und ARDS

Purpose Aim of the study was to investigate alveolar inspiration and expiration using multiscan CT. Results of a visual assessment using a scoring system were compared with density ranges known to represent alveolar ventilation best. Method Pigs were examined before and after lavage-induced ARDS. All animals were examined using dynamic multiscan CT. The visual assessment was done by a scoring system proposed by Gattinoni. The results were compared with planimetric determination of defined density ranges. Results In the healthy lung, the visual analysis showed higher scores at lower airway pressures with a marked gradient, whereas at higher pressures neither opacities nor gradients were obse…

research product

Quantification of Regional Intrapulmonary Oxygen Partial Pressure Evolution during Apnea by 3He MRI

We present a new method to determine in vivo the temporal evolution of intrapulmonary oxygen concentrations by functional lung imaging with hyperpolarized (3)Helium ((3)He-->). Single-breath, single-bolus visualization of (3)He--> administered to the airspaces is used to analyze nuclear spin relaxation caused by the local oxygen partial pressure p(O(2))(t). We model the dynamics of hyperpolarization in the lung by rate equations. Based hereupon, a double acquisition technique is presented to separate depolarization by RF pulses and oxygen induced relaxation. It permits the determination of p(O(2)) with a high accuracy of up to 3% with simultaneous flip angle calibration using no additional …

research product

19F-MRT der Lungenventilation in Atemanhaltetechnik mittels SF6-Gas

Breathhold 19 F-Magnetic Resonance Imaging of Lung Ventilation using SF 6 Gas. Objective: Development of a method to analyze lung ventilation by 19 F-magnetic resonance imaging (MRI) of inspired SF 6 gas during breathhold. Material and Methods: Measurements were performed with a Siemens Magnetom Vision 1.5T scanner using the conventional gradient overdrive. Coronal images of the lung were acquired using ultrafast gradient-echo pulse sequences with TR/TE/α = 1.4 ms/ 0.48 ms/40° without slice selection. With NEX = 200 averages and MA = 32 × 64 raw data matrix, the acquisition time was 9s/image. Higher spatial resolution of 4.7 × 6.3 × 15 mm 3 was obtained with a three-dimensional pulse sequen…

research product

The carotid pulse check revisited: What if there is no pulse?

This study was undertaken to evaluate the diagnostic accuracy and time required by first responders to assess the carotid pulse in potentially pulseless patients. We conducted a prospective, randomized study of first responders (n = 206; four different training levels) and were blinded as to the patients' conditions in the cardiac operating rooms of a university hospital. Sixteen patients underwent coronary artery bypass surgery on nonpulsatile cardiopulmonary bypasses. Carotid pulse check was performed either during pulsatile (spontaneous) or during nonpulsatile (extracorporeal) circulation. Patients' hemodynamic status at the time of assessment, diagnostic accuracy of the first responders…

research product

Lung density distribution in dynamic CT correlates with oxygenation during pressure-controlled ventilation of pigs with lavage-ARDS

research product

A novel technique to follow fast PaO2 variations during experimental CPR

An ultrafast responding fluorescent-quenching PO2 probe allows time-resolved, in vivo measurement of PO2. This study describes several validation experiments of this new device in vitro, and reports its first use during cardiopulmonary resuscitation in an animal model of cardiac arrest.The influence of CO2, temperature and motion artefacts on the signal response of the PO2 probe was analysed in vitro by systematic variation of these values. Thereafter, with approval of the Review Board for the care and use of animals, CPR was performed in four pigs. The PaO2 course was recorded continuously at time resolution of80 ms in the abdominal aorta using an uncoated fluorescence-quenching probe (Fox…

research product

Functional Evaluation of Emphysema Using Diffusion-Weighted 3Helium-Magnetic Resonance Imaging, High-Resolution Computed Tomography, and Lung Function Tests

Purpose: To assess the emphysematous enlargement of distal air-spaces and concomitant large and small airway disease using diffusion-weighted 3 Helium-magnetic resonance imaging (MRI), high-resolution computed tomography (HRCT), and lung function tests (LFT). Methods: Seven patients were examined after single lung transplantation (LTx) and 1 before double LTx for various forms of emphysema. Five patients after double LTx served as controls. Patients were assessed by 3 Helium-MRI (apparent diffusion coefficient [ADC]), HRCT (mean lung density [MLD], emphysema index [El]), and LFT. Results: Transplanted lungs: mean ADC = 0.17 cm 2 /s, MLD = -848 H, El = 22%. Emphysematous lungs: mean ADC = 0.…

research product

The Laryngeal Mask Airway: routine, risk, or rescue?

research product

Software zur automatischen Quantifizierung von Belüftungszuständen bei akutem Lungenversagen in dynamischen CT-Aufnahmen der Lunge1

Purpose: Density measurements in dynamic CT image series of the lungs allow one to quantify ventilated, hyperinflated, and atelectatic pulmonary compartments with high temporal resolution. Fast automatic segmentation of lung parenchyma and a subsequent evaluation of it's respective density values are a prerequisite for any clinical application of this technique. Material and Methods: For automatic lung segmentation in thoracic CT scans, an algorithm was developed which uses (a) different density masks, and (b) anatomic knowledge to differentiate heart, diaphragm and chest wall from ventilated and atelectatic lung parenchyma. With Animal Care Committee approval, the automated technique was t…

research product

High dose naloxone does not improve cerebral or myocardial blood flow during cardiopulmonary resuscitation in pigs

In a prospective, randomized, placebo-controlled, double-blind trial we tested the hypothesis that naloxone given during cardiopulmonary resuscitation (CPR) enhances cerebral and myocardial blood flow. Twenty-one anesthetized, normoventilated pigs were instrumented for measurements of right atrial and aortic pressures, and regional organ blood flow (radiolabeled microspheres). After 5 min of untreated fibrillatory arrest, CPR was commenced using a pneumatic chest compressor/ventilator. With onset of CPR, an i.v. bolus of 40 micrograms/kg b.w. of epinephrine was given, followed by an infusion of 0.4 micrograms/kg per min. After 5 min of CPR, either naloxone, 10 mg/kg b.w. (group N, n = 11) o…

research product

Elucidation of structure-function relationships in the lung: contributions from hyperpolarized 3 helium MRI

Magnetic resonance imaging (MRI) using hyperpolarized 3helium (He) gas as the source of signal provides new physiological insights into the structure-function relationships of the lung. Traditionally, lung morphology has been visualized by chest radiography and computed tomography, whereas lung function was assessed by using nuclear medicine. As all these techniques rely on ionizing radiation, MRI has some inherent advantages. 3He MRI is based on 'optical pumping' of the 3He gas which increases the nuclear spin polarization by four to five orders of magnitude translating into a massive gain in signal. Hyperpolarized 3He gas is administered as an inhaled 'contrast agent' and allows for selec…

research product

3He-MRI-based measurements of intrapulmonarypO2 and its time course during apnea in healthy volunteers: first results, reproducibility, and technical limitations

We applied a recently developed method of following the time course of the intrapulmonary oxygen partial pressure p(O2)(t) during apnea by (3)He MRI to healthy volunteers. Using two imaging series with different interscan times during two breathholds (double acquisition technique), relaxation of (3)He due to paramagnetic oxygen and depolarization by RF pulses were discriminated. In all four subjects, the temporal evolution of p(O2) was found to be linear, and was described by an initial partial pressure p(0) and a decrease rate R. Also, regional differences of both p(0) and R were observed. A correlation between p(0) and R was apparent. Finally, we discuss limitations of the double acquisit…

research product

3 He-MRI-based vs. conventional determination of lung volumes in patients after unilateral lung transplantation: a new approach to regional spirometry

Background: To use 3Helium (3He)-MRI in patients with unilateral lung grafts to assess the contributions of graft and native lung to total ventilated lung volume, and second to compare conventional measurements of intrapulmonary gas volume (spirometry, body plethysmography) with image-based volumetry of ventilated lung parenchyma visualized by hyperpolarized 3He-MRI. Methods: With Ethics Committee approval, five patients with single lung transplantation (SLTX) for idiopathic pulmonary fibrosis (IPF) underwent both conventional pulmonary function testing (PFT) and 3He-MRI of the lung. Intrapulmonary gas volume (GV) during the inspiratory breathhold for 3He-MRI was calculated from measured fu…

research product

Differences in the topographical distribution of EEG activity during surgical anaesthesia and on emergence from volatile anesthetics.

Computerized processing of a 16 channel EEG allows mapping and display of cortical electrical activity in a useful mode for intraoperative monitoring. We studied the topographical distribution of EEG-activity displayed as spectral maps comparing inhalational anaesthesia with isoflurane or enflurane during surgical anaesthesia and emergence. Two groups of nine patients each were anaesthetized with one of the two regimens. The EEG patterns during steady state end-tidal concentrations of isoflurane (0.7-1.1%) or enflurane (0.8-1.3%) showed highest activity in the frontal and occipital areas. At near awakening the frontal and occipital dominance of delta activity disappeared in both groups and …

research product

Reformatierungen als Lösungsansatz für die Problematik der unterschiedlichen Schichtführung beim Vergleich von3He-MRT und HR-CT der Lunge

Purpose: 3 He-MRI of the lung has been shown to be a sensitive method for functional imaging of the lung. A previous study compared 3 He-MRI (coronal planes) with CT (transverse planes) by looking for ventilation defects and their pathomorphologic correlation. Anatomic structures, such as lobar fissures and hilar vessels, were used for orientation, but the reliable assignment of ventilation defects to lung segments is problematic. The present work compares multiplanar reformations of 3 He-MRI and HR-CT, which were generated from planes determined by the respective method, and investigates their suitability as a solution of this problem. Materials and Methods: A total of 16 data sets taken f…

research product

An�sthesie zur endovaskul�ren Therapie aortaler Aneurysmen Verfahren und perioperative Risiken

Die transvaskulare Plazierung endoluminaler Gefasprothesen mittels interventionell-radiologischer Methoden ist ein neues, minimal invasives Verfahren zur Therapie von Aortenaneurysmen. Wir analysierten retrospektiv die Praktikabilitat verschiedener Anasthesieverfahren, die pathophysiologischen Auswirkungen des Eingriffs und typische Risiken. Bei 19 Patienten mit Aneurysmen der infrarenalen (n=18) oder der thorakalen Aorta (n=1) wurden in 23 Eingriffen aortale Stentprothesen implantiert. Die Eingriffe erfolgten in Allgemeinanasthesie (AA: n=9), in Periduralanasthesie (PDA: n=8) oder Lokalanasthesie (LA: n=6) mit Analgosedierung. Trotz erhohten Uberwachungsaufwands in der Gruppe AA ergaben si…

research product

SPLIT-LUNG VOLUMETRY IN PATIENTS AFTER SINGLE-LUNG TRANSPLANTATION USING 3HELIUM-MRI 

research product

Analysis of discrete and continuous distributions of ventilatory time constants from dynamic computed tomography.

In this study, an algorithm was developed to measure the distribution of pulmonary time constants (TCs) from dynamic computed tomography (CT) data sets during a sudden airway pressure step up. Simulations with synthetic data were performed to test the methodology as well as the influence of experimental noise. Furthermore the algorithm was applied to in vivo data. In five pigs sudden changes in airway pressure were imposed during dynamic CT acquisition in healthy lungs and in a saline lavage ARDS model. The fractional gas content in the imaged slice (FGC) was calculated by density measurements for each CT image. Temporal variations of the FGC were analysed assuming a model with a continuous…

research product

High-Dose ϵ-Aminocaproic Acid Versus Aprotinin: Antifibrinolytic Efficacy in First-Time Coronary Operations

The antifibrinolytic efficacy of a high-dose regimen of epsilon-aminocaproic acid (epsilon-ACA) was compared with aprotinin in first-time coronary operations.In a prospective, double-blinded, randomized study, 20 patients received high-dose epsilon-ACA (10 g both as a loading and cardiopulmonary bypass priming dose, 2.5 g/h until 4 hours after protamine), and another 20 patients received aprotinin (2 x 10(6) KIU [280 mg] for loading and priming, 0.5 x 10(6) KIU/h [70 mg/h]). Ten untreated patients served as controls.Both agents reduced postoperative levels of thrombin/antithrombin III complexes, D-dimers, fibrin degradation products, free plasma hemoglobin (epsilon-ACA versus aprotinin, p =…

research product

Dynamische Bildgebung der Nasenhaupthöhle und der Nasennebenhöhlen im MR mittels polarisiertem 3Helium

sinuses with polarized 3 helium MRI. Purpose: Reduced or blocked ventilation of the paranasal sinuses is probably the most important factor in the development of sinusitis. Recently, the use of optically polarized noble gas isotopes has attracted increasing interest for use in a variety of promising MR applications. The aim of this study was to test the feasibility of imaging and visualization ventilation of the nasal cavity and paranasal sinus in MR by inhalation of hyperpolarized 3 helium. The goal was to evaluate ventilation defects of the paranasal sinuses. Volunteers and Methods: Three volunteers were enrolled in the study. 3 Helium was polarized to 40-50% by direct optical pumping. 30…

research product

Flip angle considerations in (3)helium-MRI.

3Helium-MRI ((3)He-MRI) can be used for analysis of lung function, e. g. dynamic imaging of ventilation and gas diffusion within the lung, assessment of intrapulmonary oxygen concentrations and their time course. During imaging, the irreversible signal loss due to depolarizing radio frequency excitations can be described using the flip angle (FA) alpha. This parameter has to be quantified in order to account for it during quantitative assessment of the (3)helium signal intensity and its temporal development. This technical report reviews two different methods to determine alpha. Limitations and possible error sources of each method are discussed.

research product

Volumetry of Ventilated Airspaces by 3He MRI

To develop a validated post-processing routine for volumetry of the ventilated airspaces by 3He MRI.3Helium MRI and pulmonary function tests were performed in seven healthy volunteers. After segmentation of ventilated airspaces, their volumes were calculated. Functional residual capacity (FRC) was used as a reference. For comparison of absolute volumes, correction factors were evaluated.Mean lung volume (+/- standard deviation) calculated from 3He MRI was 4,082 +/- 908 mL and mean FRC was 3,696 +/- 1166 mL, with a mean difference of 386 mL (r = 0.88). After correction for the relative pulmonary air content (factor 0.82), posture (0.72), and the individual tidal volume, 3He MRI volume was 3,…

research product

Effect of chest compressions only during experimental basic life support on alveolar collapse and recruitment

Summary Aim The importance of ventilatory support during cardiac arrest and basic life support is controversial. This experimental study used dynamic computed tomography (CT) to assess the effects of chest compressions only during cardiopulmonary resuscitation (CCO-CPR) on alveolar recruitment and haemodynamic parameters in porcine model of ventricular fibrillation. Materials and methods Twelve anaesthetized pigs (26±1kg) were randomly assigned to one of the following groups: (1) intermittent positive pressure ventilation (IPPV) both during basic life support and advanced cardiac life support, or (2) CCO during basic life support and IPPV during advanced cardiac life support. Measurements w…

research product

Aktuelle Frühergebnisse nach pulmonaler Thrombendarteriektomie bei chronischer thromboembolischer pulmonaler Hypertonie (Early results of pulmonary thromboendarterectomy for chronic thromboembolic pulmonary hypertension)

Die pulmonale Thrombendarteriektomie ist ein potentiell kuratives Operationsverfahren bei Patienten mit chronischer thromboembolischer pulmonaler Hypertonie. Von Juni 1989 bis Dezember 1994 wurden in unserer Klinik 109 Patienten einer pulmonalen Thrombendarteriektomie unterzogen. Seit Januar 1995 wurden vielfaltige Veranderungen des operativen und postoperativen Therapiekonzepts vorgenommen. Wir berichten uber die Fruhergebnisse von 32 Thrombendarteriektomien, die von Januar 1995 bis Januar 1997 durchgefuhrt worden sind.

research product

Reduced inotropic support after aprotinin therapy during pediatric cardiac operations

Several reports indicate that aprotinin treatment before and during cardiopulmonary bypass (CPB) might have a protective effect on the myocardium. We evaluated the hemodynamic effects of perioperative aprotinin treatment.We conducted a randomized, double-blind, placebo-controlled trial in 34 infants (mean age, 2.5 years) who had cardiac operations. Half of the patients received high-dose aprotinin therapy. There were no significant differences between the aprotinin and placebo groups with respect to age, weight, sex, aortic cross-clamp time, and CPB time. The following data were recorded at arrival in the intensive care unit 6, 12, 24, and 48 hours after termination of CPB: heart rate, bloo…

research product

MRI in lung transplant recipients using hyperpolarized 3He: comparison with CT.

PURPOSE To elucidate the ability of 3He-MRI to detect ventilation defects in lung transplant recipients, 3He-MRI was compared to CT for concordance. MATERIALS AND METHODS We examined 14 lung recipients using 3He-MRI on a 1.5 T MR scanner. CT served as a reference method. Up to four representative ventilation defects were defined for each lung on 3He-MRI and compared to corresponding areas on CT. RESULTS Altogether, 59 representative ventilation defects were defined on 3He-MRI. Plausible CT correlates were found for 29 ventilation defects; less plausible CT correlates were found for eight defects. In 22 defects (37%) no corresponding CT changes were detected. CT demonstrated correlates for v…

research product

Zusammenfassung der Diskussion: „Die Aufrechterhaltung der Narkose auf intravenösem Wege“

research product

Comparison of magnetic resonance imaging of inhaled SF6 with respiratory gas analysis

Magnetic resonance imaging of inhaled fluorinated inert gases ((19)F-MRI) such as sulfur hexafluoride (SF(6)) allows for analysis of ventilated air spaces. In this study, the possibility of using this technique to image lung function was assessed. For this, (19)F-MRI of inhaled SF(6) was compared with respiratory gas analysis, which is a global but reliable measure of alveolar gas fraction. Five anesthetized pigs underwent multiple-breath wash-in procedures with a gas mixture of 70% SF(6) and 30% oxygen. Two-dimensional (19)F-MRI and end-expiratory gas fraction analysis were performed after 4 to 24 inhaled breaths. Signal intensity of (19)F-MRI and end-expiratory SF(6) fraction were evaluat…

research product

Temporal dynamics of lung aeration determined by dynamic CT in a porcine model of ARDS

We used dynamic CT to identify two different time constants of lung aeration and their individual contribution to the total increase in cross-sectional lung area in healthy and experimentally damaged lungs. In five healthy pigs, inflation and deflation between 0 and 50 cm H2O was imposed during dynamic (250 ms/image) CT acquisition, and repeated after experimental lung injury by saline lavage. The fractional areas of density ranges, which represent aerated lung parenchyma, were determined planimetrically, and their time for expansion during the manoeuvre was fitted using a bi-exponential model. Thus, two compartments, their sizes, i.e. their relative contributions to lung area aerated by th…

research product

Visualization of alveolar recruitment in a porcine model of unilateral lung lavage using3He-MRI

BACKGROUND: In the acute respiratory distress syndrome potentially recruitable lung volume is currently discussed. (3)He-magnetic resonance imaging ((3)He-MRI) offers the possibility to visualize alveolar recruitment directly. METHODS: With the approval of the state animal care committee, unilateral lung damage was induced in seven anesthetized pigs by saline lavage of the right lungs. The left lung served as an intraindividual control (healthy lung). Unilateral lung damage was confirmed by conventional proton MRI and spiral-CT scanning. The total aerated lung volume was determined both at a positive end-expiratory pressure (PEEP) of 0 and 10 mbar from three-dimensionally reconstructed (3)H…

research product

Ultraschnelle MRT der Lungenventilation mittels hochpolarisiertem Helium-3*

Objective Assessment of the temporal and spatial dynamics of hyperpolarized Helium-3 (3He) distribution in the lung with ultrafast gradient-echo magnetic-resonance imaging. Material and methods Coronal images of the lung were acquired using ultrafast gradient-echo pulse sequences with TR/TE = 3.3 ms/1.3 ms (slice thickness, 40 mm) and TR/TE = 2.0 ms/0.7 ms (without slice selection). A series of 80 or 160 projection images was obtained with 210 ms or 130 ms temporal resolution, respectively. Imaging was performed during several respiratory cycles after application of a single bolus of 300 mL hyperpolarized 3He. Measurements were performed in six healthy volunteers (spontaneous breathing). Re…

research product

Spiral-CT und 3 D-Rekonstruktion des Tracheobronchialbaumes zur Auswahl geeigneter Doppellumentuben vor Einzellungenbeatmung

Purpose To assess the potential of 3-D spiral CT in the selection of adequate double-lumen tubes (DLT) for one-lung-ventilation. Materials and methods 3-D spiral CT of eight different DLTs was performed with standardized acquisition parameters: section thickness 4 mm, table speed 6 mm/s, increment 3 mm and standardised thresholds, window settings and magnification zoom. The accuracy was confirmed by measuring 3-D objects on screen and original DLTs by vernier caliper. 3-D spiral CT was performed in 20 patients preoperatively with slice thickness 4-8 mm, pitch 1-1.5, increment 4-8 mm. To select the adequate DLT size the 3-D reconstructions of the patient's tracheobronchial tree and of the DL…

research product

Ein Auswerteprogramm zur quantitativen Analyse von Messungen des alveolären Sauerstoffpartialdrucks (pAO2) mit der sauerstoffsensitiven 3He-MR-Tomographie

Purpose: To develop a software tool for quantitative analysis of alveolar oxygen partial pressure (p A O 2 ) as well as its time course during apnea. Material and Methods: T 1 -relaxation times of hyperpolarized 3 He are reduced by paramagnetic oxygen rendering 3 He-MRI sensitive to oxygen and thus allowing the assessment of the local oxygen partial pressure in the pulmonary airspaces. Oxygen-related relaxation and loss of polarization by RF-excitation can be discriminated by acquiring two image series with varying interscan delay and/or flip angles. Software was developed to calculate the p A O 2 and the decay rate in user-defined regions of interest (ROIs) automatically. Moreover, paramet…

research product

Checking the carotid pulse check: diagnostic accuracy of first responders in patients with and without a pulse.

International guidelines for cardiopulmonary resuscitation (CPR) in adults advocate that cardiac arrest be recognized within 5-10 s, by the absence of a pulse in the carotid arteries. However, validation of first responders' assessment of the carotid pulse has begun only recently. We aimed (1) to develop a methodology to study diagnostic accuracy in detecting the presence or absence of the carotid pulse in unresponsive patients, and (2) to evaluate diagnostic accuracy and time required by first responders to assess the carotid pulse. In 16 patients undergoing coronary artery bypass grafting, four groups of first responders (EMT-1: 107 laypersons with basic life support (BLS) training; EMT-2…

research product

Dynamic computed tomography: a novel technique to study lung aeration and atelectasis formation during experimental CPR

Objective: To develop an image based technique to study the effect of different ventilatory strategies on lung ventilation and alveolar recruitment during cardiopulmonary resuscitation (CPR). Design: (1) Technical development of the following components: (a) construction of an external chest compression device, which does not interfere with CT imaging, and (b) development of a software tool to detect lung parenchyma automatically and to calculate radiological density parameters. (2) Feasibility studies: three strategies of CPR ventilation were performed and imaged in one animal each (pigs, 25 kg): volume-constant ventilation (VCV), no ventilation, or continuous airway pressure (CPAP). One m…

research product

Laryngeal Mask Airway Position and the Risk of Gastric Insufflation

A potential risk of the laryngeal mask airway (LMA) is an incomplete mask seal causing gastric insufflation or oropharyngeal air leakage.The objective of the present study was to assess the incidence of LMA malpositions by fiberoptic laryngoscopy, and to determine their influence on gastric insufflation and oropharyngeal air leakage. One hundred eight patients were studied after the induction of anesthesia, before any surgical manipulations. After clinically satisfactory LMA placement, tidal volumes were increased stepwise until air entered the stomach, airway pressure exceeded 40 cm H2 O, or air leakage from the mask seal prevented further increases in tidal volume. LMA position in relatio…

research product

Analysis of the intrapulmonary distribution of ventilation and PO2 in patients after single-lung transplantation: a 3Helium MRI study

research product

Adaptive Lung Ventilation (ALV) Evaluierung eines neuen closed loop-gesteuerten Beatmungsalgorithmus bei Eingriffen in �berstreckter Seitenlage

The lateral decubitus position is the standard position for nephrectomies. There is a lack of data about the effects of this extreme position upon respiratory mechanics and gas exchange. In 20 patients undergoing surgery in the nephrectomy position, we compared a new closed-loop-controlled ventilation algorithm, adaptive lung ventilation (ALV), which adapts the breathing pattern automatically, to the respiratory mechanics with conventionally controlled mandatory ventilation (CMV). The aims of our study were (1) to describe positioning effects on respiratory mechanics and gas exchange, (2) to compare ventilatory parameters selected by the ALV controller with traditional settings of CMV, and …

research product

High-frequency oscillatory ventilation in adults with traumatic brain injury and acute respiratory distress syndrome

This study observed adverse events of rescue treatment with high-frequency oscillatory ventilation (HFOV) in head-injured patients with acute respiratory distress syndrome (ARDS).Data of five male patients with ARDS and traumatic brain injury, median age 28 years, who failed to respond to conventional pressure-controlled ventilation (PCV) were analyzed retrospectively during HFOV. Adjusted mean airway pressure at initiation of HFOV was set to 5 cm H2O above the last measured mean airway pressure during PCV. Frequency of pulmonary air leak, mucus obstruction, tracheal injury, and need of HFOV termination due to increased intracranial pressure, decreased cerebral perfusion pressure, or deteri…

research product

Endovaskuläre Aneurysmatherapie - Langzeitergebnisse nach 7 Jahren

Hintergrund: Seit der Entwicklung von Stentprothesen und deren kommerzieller Verfugbarkeit 1994 gibt es eine neue, sich zunehmend verbreitende endovaskulare Methode der Aneurysmatherapie.

research product

Visuelle Abschätzung der funktionellen Lungenanteile in der HRCT und 3He-MRT bei Patienten nach Einzel-Lungentransplantation: Vergleich mit der absoluten Volumetrie

Purpose: Visual assessment of the ventilation using HRCT and 3 He-MRI in patients after single lung transplantation (SLTX). Analysis of specific ventilation defects found with 3 He-MRI and morphological changes found with HRCT. Materials and Methods: We evaluated 8male patients (54 ′ 6 years) suffering from emphysema and six patients (3males and 3 females, 58 ′ 9.5 years) suffering from idiopathic pulmonary fibrosis (IPF) after SLTX. The morphological changes at HRCT were classified and localized. In 3 He-MRI (2D FLASH), 10 to 14 slices (slice thickness 10 mm, gap 5 mm) were acquired in coronal orientation to cover the whole lung. Ventilation defects were localized and characterized. The vi…

research product

3He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes

MRI with hyperpolarized helium-3 (3He) provides high-resolution imaging of ventilated airspaces. The first aim of this 3He-study was to compare observations of localized signal defects in healthy smokers and non-smokers. A second aim was to describe relationships between parameters of lung function, volume of inspired 3He and signal-to-noise ratio. With Ethics Committee approval and informed consent, 12 healthy volunteers (seven smokers and five non-smokers) were studied. Imaging was performed in a 1.5 T scanner using a two-dimensional FLASH sequence at 30V transmitter amplitude (TR/TE/α = 11 ms/4.2 ms/<10°). Known amounts of 3He were inhaled from a microprocessor-controlled delivery device…

research product

Multirotations-CT während kontinuierlicher Beatmung: Vergleich unterschiedlicher Dichtebereiche bei gesunden Lungen und im Lavage-ARDS Modell

PURPOSE In this animal study, density ranges for CT-based quantification of ventilated lung area were determined. Healthy lungs and ARDS lungs were compared during artificial respiration. MATERIAL AND METHODS CT-scans were performed in 5 anesthetized pigs using a dynamic multiscan CT option on a predefined transverse slice (slice thickness 1 mm; effective temporal resolution, 250 ms). During continuous CT acquisition, airway pressure was increased or decreased in a stepwise manner. In all images, areas of defined HU ranges were determined planimetrically. The lower threshold was set to -910 HE in all images. The upper threshold was varied from -800 HE to -200 HE in steps of 100 HE. RESULTS …

research product

Evaluation of gastric intramucosal pH during and after pediatric cardiac surgery.

Objectives: In adult patients, intramucosal pH (pHi) has been advocated to detect postoperative complications. The purpose of our study was to evaluate this technique in pediatric patients during and after cardiac surgery. Methods: Thirty-five infants (age: 5 days to 15 years, median 1.8 years; and weight: 3.2‐32 kg, median 9.8 kg) were studied. pHi was measured before cardiopulmonary bypass (CPB), after 30 min of CPB, prior to weaning off CPB, at intensive care unit arrival, and 6, 12, 24, 48 and 72 h after surgery. Results: There were no complications related to the tonometer. A pathologically low pHiB 7.32 was found during surgery in less than 17%, at intensive care unit arrival in 83% a…

research product

Analysis of intrapulmonary O2concentration by MR imaging of inhaled hyperpolarized helium-3

Inhalation of hyperpolarized 3He allows magnetic resonance imaging (MRI) of ventilated airspaces.3He hyperpolarization decays more rapidly when interacting with paramagnetic O2. We describe a method for in vivo determination of intrapulmonary O2 concentrations ([O2]) based on MRI analysis of the fate of measured amounts of inhaled hyperpolarized3He in imaged regions of the lung. Anesthetized pigs underwent controlled normoventilation in a 1.5-T MRI unit. The inspired O2 fraction was varied to achieve different end-tidal [O2] fractions ([Formula: see text]). With the use of a specifically designed applicator,3He (100 ml, 35–45% polarized) was administered at a predefined time within single …

research product

Computed tomography-based tracheobronchial image reconstruction allows selection of the individually appropriate double-lumen tube size

Objectives: To determine whether individualized selection of double-lumen tubes or alternatives based on three-dimensional reconstruction of the tracheobronchial image from routine preoperative computed tomography (CT) scans leads to clinically appropriate choices. Design: Prospective observational study; comparison to historic controls. Setting: Anesthesia and radiology facilities of a university medical center. Participants: Forty-nine patients undergoing thoracic surgery requiring one-lung ventilation. Interventions: Three-dimensional image reconstruction of individual tracheobronchial anatomy was performed from routine preoperative spiral CT scans as well as from scans of five left-side…

research product

Endovaskuläre Therapie aortaler Aneurysmen: erste klinische Ergebnisse

PURPOSE A clinical study aiming at examining the implantation technique and the clinical results of a new vascular prosthesis in endovascular therapy of aneurysms of the aorta. MATERIAL AND METHODS In 21 patients (20 men of 55 to 87 years of age, average age 70 years) with aneurysms of the infrarenal abdominal aorta (AAA n = 19) and the thoracic aorta (n = 2), a self-expanding nitinol stent with outer Dacron sheath (tubular prosthesis n = 4; bifurcation prosthesis n = 17) was implanted by means of an F-18 introductory set after surgical opening of the inguinal artery. RESULTS By means of the 4 tubular prostheses and 13 of the 17 bifurcation prostheses the aneurysm was bypassed completely. I…

research product

Dynamic19F-MRI of pulmonary ventilation using sulfur hexafluoride (SF6) gas

A new method for dynamic imaging of pulmonary wash-in and wash-out kinetics of inhaled sulfur hexafluoride (SF6) gas was developed. Measurements at the fluorine-19 Larmor frequency were performed in pigs using a gradient echo pulse sequence with 0.5 ms echo time and a measurement time of 9.1 s per image. Dynamic MRI was performed during wash-in and wash-out of SF6 gas in mechanically ventilated porcine lungs. A postprocessing strategy was developed for quantitative determination of wash-out time constants in the presence of noise. Mean wash-out constants were 4.78 ± 0.48 breaths vs. 4.33 ± 0.76 breaths for left and right lung when ventilation was performed with low tidal volume, and 1.73 ± …

research product

Functional Analysis in Single-Lung Transplant Recipients

Objective To develop and evaluate a postprocessing tool to quantify ventilated split-lung volumes on the basis of 3 He-MRI and to apply it in patients after single-lung transplantation (SLTX). High-resolution CT (HRCT) was employed as a reference modality providing split air-filled lung volumes. Lung volumes derived from pulmonary function test results served as clinical parameters and were used as the “gold standard.” Material and methods Eight patients (mean age, 54 years) with emphysema and six patients (mean age, 58 years) with idiopathic pulmonary fibrosis. All patients were evaluated following SLTX. HRCT was performed during inspiration (slice thickness, 1 mm; increment, 10 mm). For c…

research product

Quantifizierung von Atelektasen bei kontrollierter Beatmung: Spiral-CT versus dynamische Einzelschicht-CT

Ziel: Dynamische CT-Untersuchungen (dCT) erlauben die Darstellung und Quantifizierung ventilierter Lungenflache und Atelektasenbildung wahrend kontinuierlicher Beatmung. Diese Studie ­vergleicht eine quantitative Auswertung einer infrakarinalen dCT-Einzelschicht mit der einer Spiral-CT der gesamten Lunge, um zu untersuchen, ob eine dynamisch gemessene Einzelschicht bezuglich der intrapulmonalen Atelektasenverteilung reprasentativ fur die Gesamtlunge ist. Material und Methoden: An 8 gesunden Schweinen erfolgte eine dCT (Schichtdicke 1 mm, zeitliches Inkrement 100 ms) wahrend kontinuierlicher Beatmung, gefolgt von einer Spiral-CT der gesamten Lunge (Schichtdicke 2 mm; Pitch 1,5; Inkrement 2 m…

research product

Respiratory Mechanics, Gastric Insufflation Pressure, and Air Leakage of the Laryngeal Mask Airway

A potential risk of the laryngeal mask airway (LMA) is incomplete mask seal, which causes air leakage or insufflation of air into the stomach. The objective of the present study was to assess respiratory mechanics, quantify air leakage, and measure gastric air insufflation in patients ventilated via the LMA. Thirty patients were studied after induction of anesthesia but prior to any surgical manipulations. After the insertion of the LMA, patients were ventilated with increasing tidal volumes until one of the three following end points were reached: 1) gastric air insufflation, 2) airway pressure > 40 cm H2O, or 3) limitation of further increase in tidal volume by air leakage. The following …

research product

Inhaled iloprost in patients with chronic thromboembolic pulmonary hypertension: effects before and after pulmonary thromboendarterectomy.

Abstract Background In primary pulmonary hypertension, aerosolized prostanoids selectively reduce pulmonary vascular resistance and improve right ventricular function. In this study, hemodynamic effects of inhaled iloprost, a stable prostacyclin analogue, were evaluated in patients with chronic thromboembolic pulmonary hypertension (CTEPH) before and early after pulmonary thromboendarterctomy (PTE). Methods Ten patients (mean age 49 years old [32 to 70 years old], New York Heart Association functional class III and IV) received a dose of 33 μg aerosolized iloprost immediately before surgery (T1), after intensive care unit admission (T2), and 12-hours postoperatively (T3). Effects on pulmona…

research product

19F-MRI of perflubron for measurement of oxygen partial pressure in porcine lungs during partial liquid ventilation

A method for in vivo measurement of oxygen partial pressure (pO2) in porcine lungs during partial liquid ventilation (PLV) with perflubron (PFOB) was developed. A pulse sequence for high-resolution MRI of the distribution of PFOB in the lung after intratracheal administration was developed as well. Moreover, quantitative measurements of longitudinal relaxation time T(1) of (19)F resonances for assessment of regional pO2 are described. Due to the need to acquire data during a single expiratory breathhold, only low SNRs were achieved in vivo. Therefore, simulations were performed to investigate the influence of background noise on T(1) values calculated from data with low SNR. Based on these …

research product

Ventilation-Perfusion Ratio in Perflubron During Partial Liquid Ventilation

BACKGROUND: Functional magnetic resonance imaging (fMRI) of fluorine-19 allows for the mapping of oxygen partial pressure within perfluorocarbons in the alveolar space (Pao(2)). Theoretically, fMRI-detected Pao(2) can be combined with the Fick principle approach, i.e., a mass balance of oxygen uptake by ventilation and delivery by perfusion, to quantify the ventilation-perfusion ratio (Va/Q) of a lung region: The mixed venous blood and the inspiratory oxygen fraction, which are equal for all lung regions, are measured. In addition, the local expiratory oxygen fraction and the end capillary oxygen content, both of which may differ between the lung regions, are calculated using the fMRI-detec…

research product

Assistierte Zirkulation bei einem 7 Tage alten Neugeborenen wegen Postkardiotomie-low-output-syndrom

Bei einem 7 Tage alten Saugling wurde ein nach anatomischer Korrektur einer d-Transposition der grosen Arterien aufgetretenes Postkardiotomie-low-output-Syndrom mittels assistierter Zirkulation behandelt. Unter Einsatz eines Zentrifu-galpumpensystems konnte die linksventrikulare Kreislaufunterstutzung bis zur Durchfuhrung eines erfolgreichen Entwohnungsverfahrens nach insgesamt 20 Stunden der Kreislaufassistenz aufrechterhalten werden. Zum Entlassungszeitpunkt war bei dem neurologisch unauffalligen Neugeborenen echokardiographisch eine komplette Erholung der linksventrikularen Funktion nachweisbar.

research product

Inhaled iloprost to control residual pulmonary hypertension following pulmonary endarterectomy.

Objective: Pulmonary endarterectomy (PEA) is the standard therapy for patients with chronic thromboembolic pulmonary hypertension (CTEPH). In the immediate postoperative period, persistent pulmonary hypertension increases the risk of acute respiratory or right heart failure. In pulmonary arterial hypertension, prostanoid inhalation has been found to improve pulmonary hemodynamics, right ventricular function, gas exchange, and clinical outcome. We report the results of a double-blinded randomized trial with the aerosolized prostacyclin analogue iloprost in patients with residual pulmonary hypertension after PEA. Methods: Twenty-two patients (age, 55 � 13 years; 8 females; propofol- and sufen…

research product

Lung density distribution in dynamic CT correlates with oxygenation in ventilated pigs with lavage ARDS † †This study contains parts of the doctoral thesis of Elena Ribel.

Background Fast dynamic computed tomography (dCT) has been used to assess regional dynamics of lung inflation and deflation processes. The aim of this study was to relate ventilation-induced changes in lung density distribution, as measured over several respiratory cycles by dCT, to oxygenation and shunt fraction in a lavage acute respiratory distress syndrome model. Methods Six anaesthetized pigs underwent pressure-constant ventilation (F I O2=1.0, inspiratory:expiratory ratio=1:1) before and after induction of lung damage by saline lavage. Mean airway pressure ( P a μ w μ ) was varied (8, 13, 18, 23, 28, 33, and 38 cm H2O) in random order. At each P a μ w μ level, dCT acquisitions were pe…

research product

Assessment of a single-acquisition imaging sequence for oxygen-sensitive (3)He-MRI.

MRI of the lungs using hyperpolarized helium-3 (3He) allows the determination of intrapulmonary oxygen partial pressures (pO2). The need to separate competing processes of signal loss has hitherto required two different imaging series during two different breathing maneuvers. In this work, a new imaging strategy to measure pO2 by a single series of consecutive scans is presented. The feasibility of the method is demonstrated in three healthy human volunteers. Maps and histograms of intrapulmonary pO2 are calculated. Changes in the oxygen concentration of the inhaled gas mixture are well reproduced in the histograms. Monte Carlo (MC) simulations of the temporal evolution of 3He hyperpolariza…

research product

Automatische Anästhesieprotokollsysteme

The introduction of electronic anaesthesia documentation systems was attempted as early as in 1979, although their efficient application has become reality only in the past few years. The advantages of the electronic protocol are apparent: Continuous high quality documentation, comparability of data due to the availability of a data bank, reduction in the workload of the anaesthetist and availability of additional data. Disadvantages of the electronic protocol have also been discussed in the literature. By going through the process of entering data on the course of the anaesthetic procedure on the protocol sheet, the information is mentally absorbed and evaluated by the anaesthetist. This i…

research product

Zusammenfassung der Diskussion: „Die intravenöse Narkoseeinleitung“

research product

Zusammenfassung der Diskussion: „Sedierung in der postoperativen Phase und in der Intensivmedizin“

research product