0000000001323547

AUTHOR

Alejandro Cerviño

showing 72 related works from this author

Power profiles in multifocal contact lenses with variable multifocal zone

2016

BACKGROUND The power profile of multifocal contact lenses has been demonstrated to report important information that could be used during the fitting process. The aim of this work is to describe the power profile of a recent set of gas permeable multifocal contact lenses as a function of the pupil radius. METHODS The measured multifocal contact lenses have a centre-distance design, and are available with five distance-vision diameters (XS, S, M, L and XL) and two different additions: Type A (up to +2.00 D) and Type B (up to +2.50 D). The optical device NIMO TR1504 (Lambda-X, Nivelles, Belgium) was used to obtain the power profile measurements. The optical lens power distribution as a functi…

Optical PhenomenaContact LensesApertureVisual AcuityRefraction Ocularlaw.invention03 medical and health sciencesNear vision0302 clinical medicineOpticslawHumansPhysicsbusiness.industryEquipment DesignPresbyopiaRadiusFunction (mathematics)Power (physics)Lens (optics)OphthalmologyVariable (computer science)030221 ophthalmology & optometrybusiness030217 neurology & neurosurgeryOptometryClinical and Experimental Optometry
researchProduct

Short-Term Changes in Light Distortion in Orthokeratology Subjects

2015

Purpose. Quantifying adaptation to light distortion of subjects undergoing orthokeratology (OK) for myopia during the first month of treatment. Methods. Twenty-nine healthy volunteers (age: 22.34 ± 8.08 years) with mean spherical equivalent refractive error −2.10 ± 0.93D were evaluated at baseline and days 1, 7, 15, and 30 of OK treatment. Light distortion was determined using an experimental prototype. Corneal aberrations were derived from corneal topography for different pupil sizes. Contrast sensitivity function (CSF) was analyzed for frequencies of 1.50, 2.12, 3.00, 4.24, 6.00, 8.49, 12.00, 16.97, and 24.00 cpd under photopic conditions. Results. Average monocular values of all light di…

Refractive errormedicine.medical_specialtyArticle Subjectgenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentLentes de contactolcsh:Medicine01 natural sciencesGeneral Biochemistry Genetics and Molecular BiologyPupil010309 optics03 medical and health sciences0302 clinical medicineDistortionCorneaOphthalmology0103 physical sciencesMedicineContrast (vision)media_commonÓpticaScience & TechnologyGeneral Immunology and Microbiologymedicine.diagnostic_testbusiness.industrylcsh:ROrthokeratologyGeneral Medicinemedicine.diseaseCorneal topographyeye diseasesmedicine.anatomical_structure030221 ophthalmology & optometrysense organsbusinessPhotopic visionResearch ArticleBioMed Research International
researchProduct

Clinical use of the ocular point spread function for retinal image quality assessment

2008

The purpose of this study is to demonstrate the clinical use of the point spread function (PSF) as metric for the assessment of retinal image quality in eyes with different ocular conditions. The PSF was computed from the wavefront aberrations obtained in seven eyes with different ocular conditions: emmetropia, myopia, hyperopia, post-myopic laser in situ keratomileusis (LASIK), post-hyperopic LASIK, keratoconus, Intacs ® in keratoconus, radial keratotomy (RK), LASIK after RK, cataract, phacoemulsification after cataract surgery, and LASIK after astigmatic keratotomy. The Strehl intensity ratio was calculated for all the PSFs computed. The PSF was correlated with the change in the optical e…

Point spread functionKeratoconusmedicine.medical_specialtygenetic structuresbusiness.industrymedicine.medical_treatmentBiomedical EngineeringEmmetropiaLASIKStrehl ratioKeratomileusismedicine.diseaseeye diseasesOphthalmologyRadial keratotomyRefractive surgeryOphthalmologyMedicineOptometrysense organsbusinessOptometryExpert Review of Ophthalmology
researchProduct

Intraocular lens centration and stability: efficacy of current technique and technology

2008

Purpose of review The manuscript presents a review of recently published studies analyzing different methodologies to assess centration and stability of intraocular lenses after implantation. Recent findings Considering that there is no current gold standard for centration and stability of intraocular lenses after implantation, we have summarized the different techniques used clinically for intraocular lenses centration and stability estimation. We have described the use of Scheimpflug imaging, the anterior segment optical coherence tomography and photography analysis used for lens position estimation. Techniques used to assess lens rotation are based on image analysis on digital retroillum…

Rotationgenetic structuresmedicine.medical_treatmentScheimpflug principleImage processingIntraocular lenslaw.inventionLens Implantation IntraocularOptical coherence tomographyAnterior Eye SegmentlawImage Processing Computer-AssistedPhotographymedicineHumansLenses Intraocularmedicine.diagnostic_testbusiness.industryGeneral MedicineCentrationeye diseasesLens (optics)OphthalmologyIntraocular lensessense organsbusinessTomography Optical CoherenceBiomedical engineeringCurrent Opinion in Ophthalmology
researchProduct

A 12-month Prospective Study of Tear Osmolarity in Contact Lens Wearers Refitted with Daily Disposable Soft Contact Lenses

2020

SIGNIFICANCE Tear osmolarity has been reported as one of the best diagnostic tests for dry eye disease and its management. Contact lens wear is thought to influence tear homeostasis. Understanding how regular wear of contact lenses and their type affect tear osmolarity is important. PURPOSE The purpose of this study was to assess changes in tear osmolarity and ocular symptoms over a period of 12 months following refitting contact lens wearers with daily disposable contact lenses. METHODS Fifty subjects aged (mean ± SD) 26 ± 4 years were refitted with either silicone-hydrogel (delefilcon A, SiHy, n = 34) or hydrogel (omafilcon A, Hy, n = 16) daily disposable soft contact lenses. Study includ…

AdultMalemedicine.medical_specialtyLower scorelaw.inventionYoung Adult03 medical and health sciences0302 clinical medicinelawProsthesis FittingSurveys and QuestionnairesOphthalmologymedicineHumansOcular Surface Disease IndexProspective StudiesDisposable EquipmentProspective cohort studybusiness.industryOsmolar ConcentrationHydrogelsContact Lenses HydrophilicTear osmolarityeye diseasesLens (optics)Contact lensOphthalmologyTearsTime course030221 ophthalmology & optometryDry Eye SyndromesFemaleDaily disposablesense organsbusiness030217 neurology & neurosurgeryOptometryOptometry and Vision Science
researchProduct

The tear film and the optical quality of the eye

2010

The stability of the tear film plays an important role in the optical quality of the eye. Various methods have been developed to quantify the contribution of the tear film to optical quality, including the double-pass optical method, Hartmann-Shack wavefront sensing, videokeratoscopy, retroillumination analysis, and interferometry. In addition to assessing the effect of tear film irregularities, these methods can aid in the diagnosis of dry-eye related conditions and the monitoring of therapy. This review describes the methodologies used to assess the relationship between the tear film and optical quality of the eye and summarizes the most important findings obtained with these methods with…

Wavefrontmedicine.medical_specialtyCorneal Wavefront AberrationMaterials sciencegenetic structuresmedicine.medical_treatmenteye diseasesOptical qualityCorneaOphthalmologyInterferometryArtificial tearsmedicine.anatomical_structureTearsOphthalmologymedicineHumansOptometryDry Eye SyndromesHuman eyesense organs
researchProduct

Evaluation of Physiological Parameters on Discomfort Glare Thresholds Using LUMIZ 100 Tool

2021

Purpose To assess the links between discomfort glare sensitivity and physiological factors such as eye biometry, refraction, skin phototype, age, and gender among a large sample of healthy human subjects. Methods A total of 489 participants who were 20 to 70 years old (241 men, 248 women) underwent discomfort glare threshold measurements via the LUMIZ 100. Eye biometry and optical quality were measured using a Zeiss IOLMaster 700 biometer and i.Profiler aberrometer. Iris color, skin tone, age, gender, eyeglasses use, chronotype, fatigue level, self-evaluation of light sensitivity, and time spent outdoors were determined. Statistical analysis was carried out using nonparametric Mann–Whitney …

AdultMalediscomfortiris colormedicine.medical_specialtyBiometrygenetic structuresPhotophobiaPopulationVision DisordersBiomedical EngineeringFrequency of usepupilAudiologyArticleIris colorYoung AdultHumansMedicineeducationFatigueAgededucation.field_of_studyLight sensitivitysunglasses usebusiness.industryskin toneGlare (vision)ChronotypeglareMiddle AgedOptical qualityOphthalmologyEyeglasseschronotypeFemalehealthy populationmedicine.symptomlightbusinessTranslational Vision Science & Technology
researchProduct

Comparison of short-term light disturbance, optical and visual performance outcomes between a myopia control contact lens and a single-vision contact…

2020

Purpose To compare the optical and visual performance of a dual-focus (DF) contact lens used for myopia control with a single-vision (SV) contact lens of the same material. Methods A randomised, double-masked crossover study. Twenty-eight healthy, myopic volunteers between 18 and 32 years of age (23.49 +/- 4.07 years) participated in this study. The sensory dominant eye for distance vision was determined. Refraction, best-corrected visual acuity (VA) and aberrations for 3 mm and 5 mm pupil diameters were quantified without a contact lens in situ. Subjects were fitted with two contact lens designs: DF and SV, both made of omafilcon A material. The Quality of Vision (QoV) questionnaire, over-…

AdultMaleTime FactorsAdolescentgenetic structuresVisual qualityControl (management)Visual AcuityVisual performanceLight disturbanceContrast Sensitivity03 medical and health sciencesYoung Adult0302 clinical medicineDouble-Blind MethodMyopiaHumansMiSightCross-Over StudiesScience & TechnologyColor VisionMultifocal contact lensContact Lenses HydrophilicSensory Systemseye diseasesTerm (time)Contact lensOphthalmologyScholarship030221 ophthalmology & optometryOptometryFemalePsychology030217 neurology & neurosurgeryMyopia controlOptometryFollow-Up Studies
researchProduct

Medium-term visual, refractive, and intraocular stability after implantation of a posterior chamber phakic intraocular lens to correct moderate to hi…

2011

To evaluate the medium-term refractive and visual outcomes and the complications after implantation of a silicone posterior chamber phakic intraocular lens (PC pIOL) for moderate to high myopia.Oftalmar, Medimar International Hospital, Alicante, Spain.Retrospective case series.Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, and intraocular pressure were evaluated during a medium-term follow-up. Postoperative complications were also studied.The study enrolled 35 eyes (mean preoperative spherical equivalent [SE] -10.25 diopters [D] ± 3.19 [SD]) of 20 patients with a mean age of 31.83 ± 8.87 years and a mean follow-up of 57.34 ± 9.24 months. The mean UDVA improved…

AdultMaleIntraocular pressuremedicine.medical_specialtyPhakic Intraocular LensesVisual acuitygenetic structuresVisual AcuityPhakic intraocular lensRefraction OcularMedium termYoung AdultPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMedicineHumansDioptreIntraocular PressureRetrospective Studiesbusiness.industryHigh myopiaPosterior Eye SegmentMiddle AgedRefractioneye diseasesSensory SystemsPosterior chamber phakic intraocular lensOphthalmologyTreatment OutcomeMyopia DegenerativeSurgeryFemalemedicine.symptombusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Effect of sport-tinted contact lenses for contrast enhancement on retinal straylight measurements

2008

PURPOSE: To investigate the effect of two tinted contact lenses (CL) designed for outdoor sports activity on the psychometric determination of retinal straylight using the compensation comparison method. METHODS: Thirteen emmetropic subjects were randomly fitted with two different tinted Nike Maxsight (Bausch & Lomb, Rochester, NY, USA) CL in one eye, while the contralateral eye was fitted with a clear lens made of the same material (Optima 38, Bausch & Lomb). Three valid straylight measurements were taken on each eye before and a few minutes after lens insertion, when lens stabilization had occurred. RESULTS: The subjects' mean straylight values were 0.90 +/- 0.09 at baseline and 0.95 +/- …

Maleretinal straylightgenetic structuresPolymaconEmmetropiatinted lenslaw.inventionSports Equipmentchemistry.chemical_compound0302 clinical medicinelawScattering RadiationContrast (vision)media_commonSpectral filtersVision TestsEquipment DesignSensory SystemsLens (optics)Regression AnalysisFemalePhotopic visionAdultmedicine.medical_specialtyPsychometricsContact Lensescontact lensmedia_common.quotation_subjectLight scatterColorRetinaStatistics NonparametricContrast Sensitivity03 medical and health sciencesTinte contact lensOcular straylightOphthalmologymedicineHumansOcular straylightElectronic Data ProcessingScience & TechnologyRetinalContact lensOphthalmologyocular scatterchemistrypolymacon030221 ophthalmology & optometryOptometry030217 neurology & neurosurgeryOptometryOphthalmic and Physiological Optics
researchProduct

VisuMax®femtosecond laser for corneal refractive surgery

2008

Femtosecond lasers are increasingly present in ophthalmologic surgical theaters for a variety of reasons. These include faster and better visual outcomes, increased accuracy and predictability for corneal flap thickness in laser in situ keratomileusis procedures. Recent applications of modern femtosecond lasers have broadened the range of uses: keratoplasty, intrastromal segment insertion and even glaucoma and presbyopia surgery. This device profile provides an overview of the advantages of femtosecond lasers in ophthalmic surgery, paying special attention to the new VisuMax® femtosecond laser from Zeiss/Meditec.

genetic structuresbusiness.industrymedicine.medical_treatmentBiomedical EngineeringGlaucomaKeratomileusisPresbyopiaequipment and suppliesmedicine.diseaseLasereye diseaseslaw.inventionOphthalmologyOpticsCorneal surgerylawRefractive surgeryFemtosecondmedicinesense organsbusinessOptometryOphthalmic surgeryExpert Review of Ophthalmology
researchProduct

Corneal thickness differences between sexes after oxybuprocaine eye drops.

2014

PURPOSE We aimed to analyze the corneal thickness (CT) values of female and male subjects before and after instillation of oxybuprocaine 0.4% anesthetic eye drops. METHODS The CT of 30 female subjects and 28 male subjects was measured using scanning-slit corneal topography (Orbscan Topography System II, Orbscan, Inc, Salt Lake City, UT). Measurements were carried out before and 3 minutes after the instillation of oxybuprocaine 0.4% eye drops. RESULTS The difference between the baseline values and those obtained after anesthesia ranged as follows: male subjects: central, -26 to +24 μm; superior, -24 to +23 μm; inferior, -19 to +20 μm; nasal, -25 to +30 μm; and temporal, -21 to +20 μm; female…

AdultMalemedicine.medical_specialtyAdolescentSalt lakeCorneaYoung AdultSex FactorsOphthalmologymedicineHumansProspective StudiesOxybuprocaineAnesthetics LocalBaseline valuesmedicine.diagnostic_testbusiness.industryCorneal TopographyOrgan SizeCorneal topographyOphthalmologyAnestheticFemaleOphthalmic SolutionsbusinessProcaineOptometrymedicine.drugOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Performance of the compensation comparison method for retinal straylight measurement: effect of patient's age on repeatability

2008

Aim: The assessment of repeatability and reproducibility of retinal straylight measurements with the C-Quant straylight meter (Oculus AG, Germany) and the effect of patient’s age on the instrument performance are tested with a series of experiments. Methods: First, 20 eyes from 20 subjects (mean age 26.9 (SD 2.7) years, mean refractive error −1.34 (2.72) D) were examined with the C-Quant straylightmeter, taking 10 consecutive readings. Five subjects were also examined on five consecutive days to assess reproducibility. Additionally, repeated measures of straylight from 84 subjects of ages ranging from 19 to 86 years (mean (SD): 42.4 (24.0) years) were retrospectively analysed to assess the …

AdultMalemedicine.medical_specialtyRefractive errorPsychometricsRetinaCellular and Molecular Neurosciencechemistry.chemical_compoundOphthalmologymedicineHumansScattering RadiationAgedAged 80 and overAnalysis of VarianceReproducibilitybusiness.industryOphthalmoscopesAge FactorsRepeated measures designRetinalMean ageRepeatabilityMiddle AgedRefractive Errorsmedicine.diseaseSensory SystemsOphthalmoscopyOphthalmologychemistryOptometryFemalebusinessBritish Journal of Ophthalmology
researchProduct

The Effect of Anesthetic Eye Drop Instillation on the Distribution of Corneal Thickness

2012

PURPOSE To address the effect of topical instillation of oxybuprocaine on the relative distribution of corneal thickness (CT) in young healthy subjects. METHODS Prospective study involving 30 eyes of 30 emmetropic subjects (24 ± 3 years). Corneal thickness measurements were carried out before and 3 minutes after the instillation of oxybuprocaine 4% using slit-scanning corneal topography (Orbscan topography system II). No acoustic correction factor was applied. The mean of 5 consecutive Orbscan measurements was obtained at the center and 3 mm from the visual axis in the temporal, superior, nasal, and inferior hemimeridians. RESULTS No significant mean differences were found at any corneal lo…

Malemedicine.medical_specialtyAdministration Topicalmedicine.medical_treatmentEmmetropiaTopical anestheticCorneaTonometry OcularYoung AdultOphthalmologyCorneamedicineHumansDistribution (pharmacology)Prospective StudiesAnesthetics LocalOxybuprocaineIntraocular Pressuremedicine.diagnostic_testbusiness.industryCorneal TopographyEye dropEmmetropiaCorneal topographyeye diseasesOphthalmologymedicine.anatomical_structureAnesthesiaAnestheticFemalesense organsOphthalmic SolutionsbusinessProcainemedicine.drugCornea
researchProduct

Tear film stability over a myopia control contact lens compared to a monofocal design

2021

Background: To compare the short-term effect of two contact lenses on pre-lens tear film stability and comfort: dual-focus contact lens (MiSight) and a monofocal contact lens (Proclear 1-day).Methods: This randomised, double-masked, crossover study was performed in twenty-eight healthy, myopic volunteers aged between 18 and 32 years (23.5 +/- 4.1 years). Only one randomly chosen eye was assessed. Distance vision and refraction were evaluated at baseline. Each contact lens type (monofocal and dual-focus) was randomly fitted, always in both eyes. A visual analogue scale between 0 and 10 was used to assess general comfort, physical comfort, and visual comfort. Tear Film Surface Quality (TFSQ) …

AdultMaterials scienceAdolescentCiências Naturais::Ciências FísicasYoung Adult03 medical and health sciences0302 clinical medicineMyopiatear film stabilityHumans030304 developmental biology0303 health sciencesCross-Over StudiesScience & TechnologyDual-focus contact lensfood and beveragesContact Lenses Hydrophiliceye diseasesContact lensOphthalmologyTears030221 ophthalmology & optometryOptometrysense organsmultifocal contact lensOptometry
researchProduct

OCT applications in contact lens fitting

2022

Optical Coherence Tomography (OCT) is a noninvasive, high-speed, high-resolution imaging technology based in the Michaelson interferometry. A near-infrared light beam is used to register the intensity variations for the light backscattered on each sample layer. Due to the high repeatability on corneal measurements, spectral domain OCT (SD-OCT) is the gold standard when talking about in vivo, non-invasive anterior segment imaging. Changes in the morphology of various ocular surfaces such as the cornea, conjunctiva, limbus or tear film with soft (SCL), rigid, corneal or scleral lens (SL) wear can be described by OCT measurements. For instance, evaluation of the corneoscleral region is essenti…

Materials sciencegenetic structuresmedicine.medical_treatmentlaw.inventionCorneaOptical coherence tomographyScleral lenslawCorneamedicineHumansmedicine.diagnostic_testOrthokeratologyGeneral MedicineRepeatabilityContact Lenses Hydrophiliceye diseasesContact lensLens (optics)OphthalmologyInterferometrymedicine.anatomical_structureTearssense organsConjunctivaTomography Optical CoherenceOptometryBiomedical engineeringContact Lens and Anterior Eye
researchProduct

Ocular autofluorescence in diabetes mellitus. A review

2016

Diabetes mellitus is a metabolic disease with a considerable impact on healthcare owing to its increased prevalence and high mortality rate. Structural, morphological, and physiological changes in each of the ocular components have been described in detail. Autofluorescence has been described as a good indicator of metabolic activity. The aim of the present review is to provide an overview of ocular endogenous fluorophores in the cornea, the crystalline lens, and the retinal pigment epithelium, the effects of diabetes mellitus and therefore the potential of autofluorescence assessment for screening and monitoring changes in diabetic patients.

0301 basic medicinemedicine.medical_specialtyRetinal pigment epitheliumbusiness.industryEndocrinology Diabetes and Metabolismmedicine.diseaseeye diseases03 medical and health sciencesAutofluorescence030104 developmental biology0302 clinical medicinemedicine.anatomical_structureOphthalmologyDiabetes mellitusCornea030221 ophthalmology & optometryMedicinesense organsMetabolic diseasebusinessMetabolic activityJournal of Diabetes
researchProduct

Neural Adaptation to Optical Quality Defects

2010

From an optical perspective the eye is far from perfect. This is a fact that is extensively supported by literature; for instance, Prof. Navarro recently provided us with a fantastic critical review on the various theories behind the different eye models and their flaws.1 The human eye has considerable amounts of higher-order aberrations even when it is emmetropic,2 with great inter-individual variability. Besides, higher-order aberrations are still postulated to have a role in the development of the refractive error, although it is not clear the extent to which this may be (see Charman WN for a review).3 The known optical limitations of the normal human eye raised the question as to what t…

WavefrontRefractive errorgenetic structuresbusiness.industryComputer scienceImage qualityNeural adaptationPerspective (graphical)EmmetropiaAdaptation (eye)medicine.diseaseeye diseasesEditorialmedicine.anatomical_structurelcsh:Ophthalmologylcsh:RE1-994medicinelcsh:QC350-467Computer visionHuman eyeArtificial intelligencebusinesslcsh:Optics. LightOptometryJournal of Optometry
researchProduct

Intrasubject repeatability of corneal power, thickness, and wavefront aberrations with a new version of a dual rotating Scheimpflug–Placido system

2014

Purpose To determine the intrasubject repeatability of a recently introduced dual-camera rotating Scheimpflug–Placido imaging system (Galilei G4) in determining corneal thickness, power, and wavefront aberrations in young healthy subjects. Setting University of Valencia, Valencia, Spain. Design Prospective evaluation of diagnostic technology. Methods The study comprised right eyes of 25 subjects aged 20 to 40 years with a spherical equivalent ranging from −4.25 to +1.00 diopters. The central corneal thickness, thinnest point value and location, anterior and posterior surface curvatures, total corneal power, and corneal wavefront aberrations were measured for distance vision using the dual S…

AdultMaleChord (geometry)medicine.medical_specialtyCorneal Wavefront AberrationCorneal Pachymetrygenetic structuresIntraclass correlationScheimpflug principleDiagnostic Techniques OphthalmologicalAstigmatismRefraction OcularCorneaYoung AdultOpticsOphthalmologyPhotographymedicineHumansProspective StudiesCorneal pachymetryDioptreMathematicsObserver VariationWavefrontmedicine.diagnostic_testbusiness.industryReproducibility of ResultsRepeatabilitymedicine.diseaseHealthy Volunteerseye diseasesSensory SystemsOphthalmologyFemaleSurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Corrigendum to “Short-term changes in light distortion in orthokeratology subjects"

2015

Artigo completo publicado na revista "BioMed Research International, (2015), 1-7" e disponível no RepositóriUM em: http://hdl.handle.net/1822/33375

AdultMaleAdolescentLightmedicine.medical_treatmentVisual AcuityLentes de contactolcsh:MedicineBioinformaticsGeneral Biochemistry Genetics and Molecular BiologyContrast SensitivityCorneaYoung AdultDistortionMyopiamedicineHumansÓpticaScience & TechnologyGeneral Immunology and Microbiologybusiness.industrylcsh:ROrthokeratologyCorneal TopographyGeneral MedicineRefractive ErrorsTerm (time)OptometryFemaleCorrigendumbusinessOrthokeratologic Procedures
researchProduct

Optical quality after instillation of eyedrops in dry-eye syndrome

2010

Purpose To study the effect of eyedrop instillation on the optical quality of the air–tear film interface at the anterior cornea in cases of dry eye. Setting University of Valencia, Valencia, Spain. Methods Corneal aberrations (total, spherical-like, and coma-like) were determined from corneal elevation maps and purpose-designed software in cases of dry eye before, immediately after, and 10 minutes after lubricating eyedrop instillation (Blink Intensive Tears). All data were decomposed using Zernike polynomials to yield the root-mean-square wavefront deviations for pupil diameters of 3.0 mm and 5.5 mm. Outcome measures included comparison with clinical tear breakup time (TBUT). Results Wave…

Malemedicine.medical_specialtyCorneal Wavefront Aberrationgenetic structuresmedicine.medical_treatmentEye diseaseVision DisordersDry Eye SyndromesPupilCorneaCorneaOphthalmologymedicineHumansmedicine.diagnostic_testbusiness.industryAirCorneal TopographyMiddle Agedmedicine.diseaseCorneal topographyeye diseasesSensory SystemsOptical qualityOphthalmologyArtificial tearsmedicine.anatomical_structureTearsTearsDry Eye SyndromesFemaleSurgerysense organsOphthalmic SolutionsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Determination of corneal volume from anterior topography and topographic pachymetry: application to healthy and keratoconic eyes

2009

Purpose: To describe a method to measure corneal volume from topography and pachymetry, and test its clinical use on a sample of healthy human subjects and a case of circumscribed posterior keratoconus. Methods: Corneal curvature (PCT 200® corneal topography system; Optopol Technology SA, Zawiercie, Poland) and ultrasonic topographic pachometry on 25 points (Ophthasonic ® A-Scan/Pachometer III; Teknar Inc., St Louis, MO, USA) were measured on each of 12 young healthy corneas and one cornea suffering from circumscribed posterior keratoconus. Topography and pachymetry data were used to calculate the coordinates for the corresponding points on the posterior surface of the cornea. TableCurve 3D…

MaleKeratoconusmedicine.medical_specialtygenetic structuresEye diseaseKeratoconusSensitivity and SpecificityCorneaYoung Adult03 medical and health sciences0302 clinical medicineCorneaOphthalmologymedicineHumansPosterior keratoconusCorneal pachymetry030304 developmental biology0303 health sciencesmedicine.diagnostic_testbusiness.industryCorneal TopographyCorneal topographymedicine.diseaseeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structure030221 ophthalmology & optometryFemalesense organsTomographybusinessTomography Optical CoherenceOptometryVolume (compression)Ophthalmic and Physiological Optics
researchProduct

Analysis of the possible benefits of aspheric intraocular lenses: review of the literature.

2008

We reviewed recently published studies that analyzed the visual and optical quality in eyes with different spherical and aspheric intraocular lenses (IOLs). Recent studies focused on visual quality metrics, such as visual acuity and contrast sensitivity, under photopic and mesopic lighting conditions and optical metrics, such as wavefront aberrations, especially spherical aberration. The results in this review were used in an attempt to understand whether there is a visual and/or optical benefit of implanting aspheric IOLs over implanting spherical IOLs.

Visual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityOpticsLens Implantation IntraocularMedicineContrast (vision)Humansmedia_commonWavefrontLenses Intraocularbusiness.industryeye diseasesSensory SystemsOphthalmologySpherical aberrationIntraocular lensesOptometrySurgerysense organsmedicine.symptombusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Prevalence of corneal astigmatism before cataract surgery.

2008

To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates.University of Valencia, Valencia, Spain.Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges.Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in…

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresmedicine.medical_treatmentEye diseaseIntraocular lensCataract ExtractionAstigmatismCorneal DiseasesVision disorderAge DistributionCorneaOphthalmologymedicinePrevalenceHumansProspective StudiesAgedAged 80 and overbusiness.industryAstigmatismCataract surgeryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureSpainOptometrySurgeryFemalesense organsmedicine.symptombusinessCorneal astigmatismJournal of cataract and refractive surgery
researchProduct

Online Vs In-person Education: Evaluating the Potential Influence of Teaching Modality on Dry Eye Symptoms and Risk Factors During the COVID-19 Pande…

2021

OBJECTIVES: To assess the potential effects of switching to online lecture format on dry eye symptoms and dry eye disease (DED) risk factors. METHODS: An anonymous cross-sectional online survey was conducted in 812 university students (mean age, 21.5±4.0 years). Participants were classified according to the number of hours the participants took online lectures into online students or in-person students. Respondents completed a total of three DED questionnaires (Ocular Surface Disease Index [OSDI]; 5-item Dry Eye Questionnaire; 8-item Contact Lens Dry Eye Questionnaire) and were surveyed on dry eye risk factors contemplated by the Tear Film and Ocular Surface Society Dry Eye Workshop II in a…

Adultmedicine.medical_specialtyCoronavirus disease 2019 (COVID-19)AdolescentCross-sectional studyDry Eye SyndromesLogistic regressionYoung AdultRisk FactorsSurveys and QuestionnairesMedicineHumansOcular Surface Disease IndexYoung adultPandemicsbusiness.industrySARS-CoV-2COVID-19eye diseasesContact lensOphthalmologyCross-Sectional StudiesTearsLower prevalencePhysical therapyDry Eye SyndromesbusinessEyecontact lens
researchProduct

A pilot study on the differences in wavefront aberrations between two ethnic groups of young generally myopic subjects

2008

A comparative population-based cross-sectional study design was used to examine the prevalence of wavefront patterns in two different ethnic groups, and the relationship of these patterns with ocular biometrics and gender. The Shin–Nippon SRW5000 open field autorefractor, the Wavefront Analysis Supported Customized Ablation (WASCA) wavefront analyser and the IOLMaster were used to determine wavefront aberrations, mean spherical equivalent (SE) refractive error and axial length (AL). Seventy-four eyes from 74 young healthy subjects (44 British Asians, 30 Caucasians; 36 men, 38 women; mean age 22.51 ± 3.89 years) with mean SE averaging )1.90 ± 2.76 D (range )10.88 to +2.19 D) were examined. R…

WavefrontRefractive erroreducation.field_of_studyPopulationComa (optics)medicine.diseaseSensory SystemsPearson product-moment correlation coefficient03 medical and health sciencesOphthalmologysymbols.namesakeAberrations of the eye0302 clinical medicineAutorefractorStatisticsLinear regression030221 ophthalmology & optometrymedicinesymbolsOptometryeducation030217 neurology & neurosurgeryOptometryMathematicsOphthalmic and Physiological Optics
researchProduct

Quantitative corneal anatomy: evaluation of the effect of diabetes duration on the endothelial cell density and corneal thickness.

2014

Purpose To evaluate the differences in endothelial cell density (ECD) and central corneal thickness (CCT) between type II diabetic patients and age-matched healthy controls, and determine the impact of time from diagnosis. Methods This is a comparative study of 77 eyes of type II diabetic patients (33 males, 44 females) and 80 eyes of healthy subjects (42 males, and 38 females) whose ages ranged from 38 to 56 years. CCT, ECD, HbA1c levels, and Goldmann tonometry were measured. Results The CCT was significantly higher and the ECD significantly lower in long-term diabetic patients (10 years + since diagnosis) when compared with short-term diabetic patients (<1 year since diagnosis) and contro…

Diabetes durationAdultMalemedicine.medical_specialtyTime Factorsgenetic structuresCorneal PachymetryCell CountType ii diabetesCorneaHba1c levelOphthalmologyInternal medicineMedicineHumansRetrospective StudiesGlycated Hemoglobinbusiness.industryEndothelium CornealHealthy subjectsMiddle AgedCorneal structureeye diseasesSensory SystemsEndothelial cell densityGoldmann tonometryOphthalmologyEndocrinologyDiabetes Mellitus Type 2Disease ProgressionFemalesense organsAnalysis of variancebusinessOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Preliminary in vivo positional analysis of a posterior chamber phakic intraocular lens by optical coherence tomography and its correlation with clini…

2012

Purpose: To analyze by spectral-domain optical coherence tomography the anatomical relationship of a specific type of posterior chamber phakic intraocular lens (pIOL) implanted in cases of high to moderate myopia with the adjacent intraocular structures and to correlate it with clinical outcomes. Methods: Prospective observational case series including 18 eyes with high to moderate myopia (spherical equivalent between −5.88 and −15.75 D) of 9 patients (age range, 29–49 years) undergoing bilateral Phakic Refractive Lens (PRL, Zeiss) implantation. Postoperative visual acuity, refraction, contrast sensitivity (CS), and ocular higher order aberrations (HOA) were evaluated. Furthermore, the in v…

medicine.medical_specialtygenetic structuresSpectral domainPositional analysislcsh:OphthalmologyOptical coherence tomographyIn vivoOphthalmologymedicinelcsh:QC350-467Optical coherence tomographymedicine.diagnostic_testbusiness.industrySpectral-domaineye diseasesPosterior chamber phakic intraocular lensTomografía de coherencia ópticaLentes refractivas fáquicaslcsh:RE1-994Anatomical relationshipOriginal Articlesense organsDominio espectralPhakic Refractive Lens (PRL)businesslcsh:Optics. LightOptometryJournal of Optometry
researchProduct

Effect of contact lens surface properties on comfort, tear stability and ocular physiology.

2018

Aim: Retrospective analysis of different contact lens wearing groups suggests lens surface lubricity is the main factor influencing contact lens comfort. However, the examined commercially available contact lenses differ in material and design as well as surface properties. Hence this study isolates the contribution of lens surface properties using an ultra-thin coating technology. Methods: Nineteen habitual contact lens wearers (21.6. ±. 1.7years) wore formofilcon B soft monthly disposable contact lenses with and without coating technology modified surface properties for a month each in a randomised double-masked cross-over study. Objective non-invasive: breakup time (NIKBUT), NIKBUT avera…

0301 basic medicineMalemedicine.medical_specialtyVisual analogue scaleSurface Propertieslaw.invention03 medical and health sciencesOcular physiologyYoung Adult0302 clinical medicineOpticsDouble-Blind MethodlawOphthalmologySurveys and QuestionnairesRetrospective analysisMedicineHumansCoefficient of frictionDisposable EquipmentRetrospective StudiesCross-Over Studiesbusiness.industryGeneral MedicineContact Lenses Hydrophiliceye diseasesLens (optics)Contact lensOphthalmology030104 developmental biologyPatient SatisfactionTears030221 ophthalmology & optometryFemalebusinessGrading scaleOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Short-Term Impact of FS-LASIK and SMILE on Dry Eye Metrics and Corneal Nerve Morphology

2020

PURPOSE To analyze the short-term (up to 1 month) clinical outcomes in patients undergoing corneal laser refractive surgery and the impact on dry eye disease (DED) metrics and corneal nerves using in vivo confocal microscopy (IVCM). METHODS The unaided distance visual acuity, corrected distance visual acuity, and spherical equivalent refraction (SEQ) were determined in 16 and 13 patients undergoing FS-LASIK and SMILE, respectively. DED metrics assessed were Ocular Surface Disease Index, Dry Eye Questionnaire 5-items (DEQ-5), tear film osmolarity, tear meniscus height, noninvasive keratograph breakup time (NIKBUT), ocular staining, and meibomian gland atrophy. An automated analysis of cornea…

AdultMalemedicine.medical_specialtyTime FactorsVisual acuitygenetic structuresCorneal nervemedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityMeibomian glandKeratomileusisRefraction OcularCornea03 medical and health sciencesNerve Fibers0302 clinical medicineAtrophyRefractive surgeryOphthalmologymedicineHumansOcular Surface Disease IndexProspective StudiesMicroscopy Confocalbusiness.industryLASIKmedicine.diseaseeye diseasesOphthalmologymedicine.anatomical_structure030221 ophthalmology & optometryDry Eye SyndromesFemaleLasers Excimersense organsmedicine.symptombusiness030217 neurology & neurosurgeryFollow-Up StudiesCornea
researchProduct

Subjective Satisfaction in Long-term Orthokeratology Patients

2013

Purpose: To AU3 evaluate the subjective satisfaction in visual stability, night vision complains, and light distortion phenomena, and also the number of hours and days per week of lens wear, in patients with myopia undergoing orthokeratology (OK) treatment for at least 1 year. Methods: A visual analog scale (VAS) questionnaire containing 18 items was administered to 44 patients, 29 women and 15 men (mean age, 24.39 6 9.11 years), with a baseline spherical equivalent refractive error of 22.40 6 0.94 diopters and astigmatism up to 20.5 diopters. Average treatment period by the time of data collection was 19 6 7 months. Patients rated their satisfaction with the correction, with complaints of …

AdultMaleLight distortionVisual acuityAdolescentvisual acuitygenetic structuresmedicine.medical_treatmentSubjective satisfactionRefraction OcularYoung Adult03 medical and health sciences0302 clinical medicineOpticsSurveys and QuestionnairesNight visionHumansMedicineIn patientChildPain Measurement030304 developmental biologyAU6 visual acuity0303 health sciencesScience & Technologybusiness.industryOrthokeratologyMiddle AgedRefractive Errorseye diseasesCorneal refractive therapy3. Good healthTerm (time)OphthalmologyPatient Satisfaction030221 ophthalmology & optometryPatient ComplianceOptometryFemalemedicine.symptomOvernight orthokeratologybusinessOrthokeratologic ProceduresEye &amp; Contact Lens: Science &amp; Clinical Practice
researchProduct

Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT

2015

In this study, we aimed to evaluate the intra/inter-session and intra/inter-observer variability of manual segmentation of thickness of the pre-lens tear film, contact lens (CL), post-lens tear film, epithelium, bowman’s layer, stroma and the whole cornea and CLs with a flat and a steep fit, using a commercial high-resolution spectral domain optical coherence tomographer (OCT). Two different observers obtained three repeated measures in two separate sessions. A high correlation was found between the values obtained by the two different observers, except for the thinner layers, epithelium, and Bowman’s layer. Inter-observer analysis showed a high consistency in the measurements obtained by b…

Materials scienceManual layer segmentationOpticsCLs upper limitsOptical coherence tomographyCorneamedicineEpithelial thicknessRepeatabilityScience & Technologymedicine.diagnostic_testOptical coherence tomographybusiness.industryResolution (electron density)RepeatabilityAtomic and Molecular Physics and Opticseye diseasesTear film thicknessContact lensCorneal thicknessmedicine.anatomical_structureManual segmentationsense organsbusinessBiomedical engineering
researchProduct

Optical quality of the diabetic eye: a review

2014

Diabetes mellitus is a metabolic disorder characterized by the presence of chronic hyperglycaemia. Several structural, morphological, and physiological changes in each of ocular component have been described in detail during the past decades. Due to these abnormalities, the diabetic patient undergoes a degradation of the retinal image by an increase of higher ocular aberrations and ocular scattering coming from mainly tear film, cornea, and crystalline lens. This review aims to provide an overview of current knowledge about the effects of diabetes mellitus in these optical phenomena and its consequence on the visual quality of the diabetic patient.

medicine.medical_specialtygenetic structuresGlaucomaReviewRetinaOphthalmic pathologyNeuro-ophthalmologyCorneaCorneaOphthalmologyDiabetes mellitusLens CrystallinemedicineDiabetes MellitusHumansRetinabusiness.industryMetabolic disordermedicine.diseaseRefractive Errorseye diseasesVitreous BodyOphthalmologymedicine.anatomical_structureLens (anatomy)Optometrysense organsbusiness
researchProduct

Comparison of two artificial tear formulations for dry eye through high‐resolution optical coherence tomography

2011

Purpose:  The aim was to determine the efficacy of two artificial eye-drop formulations by analysing the lower tear film meniscus volume through a commercial high-resolution spectral-domain optical coherence tomographer. Methods:  Twenty dry eye patients (12 men, eight women, aged 57.5 ± 8.4 years) with refractive errors from -2.50 to +0.75 D (mean -1.34 ± 1.02 D) and cylinders lower than 1.00 D were examined. Tear meniscus volume was measured before, immediately after and 10, 30 and 60 minutes after instillation using the Copernicus high-resolution spectral-domain optical coherence tomographer (Optopol Tech SA, Zawiercie, Poland). Volume was calculated from the local area obtained from tom…

Malemedicine.medical_specialtyDrug Compoundingmedicine.medical_treatmentDry Eye SyndromesHigh resolutionMeniscus (anatomy)Young AdultOptical coherence tomographyReference ValuesOphthalmologymedicineHumansSurface Tensionmedicine.diagnostic_testbusiness.industryImage Enhancementeye diseasesSurgeryOphthalmologyArtificial tearsmedicine.anatomical_structureVolume (thermodynamics)TearsTearsDry Eye SyndromesFemalesense organsEyelidOphthalmic SolutionsbusinessTomography Optical CoherenceFollow-Up StudiesOptometryClinical and Experimental Optometry
researchProduct

Visual and optical performance with hybrid multifocal intraocular lenses

2010

During the past years, the wish to become independent of spectacles has been growing among cataract and presbyopic patients due to many factors, such as the increase in near visual demands, the aesthetic need for a spectacle-free image and ageing of refractive surgery patients, among others. This review assesses recently published studies that analyse visual and optical performance through different metrics of eyes implanted with multifocal intraocular lenses (IOLs), particularly hybrid IOL designs. The published evidence suggests that hybrid multifocal IOLs provide very good outcomes in a number of visual and optical performance parameters. Patients implanted with this type of IOL obtain a…

Intraocular LensesOptical PerformanceVisual acuitygenetic structuresCompensation Comparisonmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityMethodKeratomileusislaw.inventionGlareLensTratamiento médicoSensitivitylawRefractive surgeryMedicineContrast (vision)MonovisionPostoperative Periodmedia_commonVistaLenses IntraocularMultifocalsGlare (vision)Equipment DesignRefractive ErrorsLens (optics)Bilateral ImplantationApodized Diffractive IolOftalmologíamedicine.symptommedicine.medical_specialtyIn-Situ KeratomileusisRefractivemedia_common.quotation_subjectHigh-Order AberrationsContrast SensitivityOphthalmologyAberrometryClinical-OutcomesHumansRetinal StraylightDepth Perceptionbusiness.industryAberrometryMultifocal intraocular lensContrasteye diseasesOphthalmologyOptometrysense organsbusinessOptometry
researchProduct

Retroespalhamento luminoso das córneas de pacientes com diabete melito dependente e não dependente de insulina: estudo piloto

2017

ABSTRACT Purpose: To compare central corneal backscatter obtained from Scheimpflug images between patients with insulin-dependent and non-insulin-dependent diabetes mellitus (IDDM and NIDDM, respectively) and healthy controls. Methods: Seven patients with IDDM (7 eyes), eleven patients with NIDDM (11 eyes), and sixteen healthy subjects (16 eyes) were included in this pilot study. Scheimpflug imaging system (Pentacam, Oculus Inc., Germany) was used to obtain optical sections of the cornea. Seven meridians were analyzed for each eye, oriented from 70° to 110°. Optical density values for the central 3-mm and 5-mm zones of the cornea were obtained by image analysis using external software. Resu…

MaleVisual acuityCorneal Pachymetrygenetic structuresScheimpflug principleVisual AcuityPilot ProjectsDiagnostic Techniques OphthalmologicalCorneal DiseasesCornea0302 clinical medicineDiabetes mellituslcsh:OphthalmologyReference ValuesCorneaMedicineCorneal pachymetrymedicine.diagnostic_testCorneal DiseasesAge FactorsScheimpflug imagingGeneral MedicineMiddle AgedCorneal topographymedicine.anatomical_structureDiabetes mellitus tipo 2Diabetes mellitus tipo 1Femalemedicine.symptomAdultmedicine.medical_specialtyProjetos pilotoStatistics Nonparametric03 medical and health sciencesAnterior Eye SegmentDiabetes mellitusOphthalmologyHumansScheimpflug Topografia da córneaAgedbusiness.industryCase-control studyReproducibility of ResultsDiabetes mellitus type 1Diabetes mellitus type 2medicine.diseaseeye diseasesOphthalmologyPilot projectDiabetes Mellitus Type 1Diabetes Mellitus Type 2lcsh:RE1-994Case-Control Studies030221 ophthalmology & optometrysense organsCorneal topographybusiness030217 neurology & neurosurgery
researchProduct

Response of the aging eye to first day of modern material contact lens wear

2018

Objectives: To investigate the ocular surface of an aged population wearing a daily disposable contact lens over their first day of wear. Methods: Forty eyes from forty presbyopic subjects were fitted a daily CL (Delefilcon A). Tear osmolarity, tear meniscus area (TMA) and ocular surface aberrations (total higher order root means square (RMS)) were assessed at baseline (t0), at 20 minutes (t1) and after 8 hours (t2) of wear. Fluorescein corneal and conjunctival staining and tear break up time (TBUT) were performed at t0 and t2. Results: No statistically significant changes were found between t0, t1 and t2 for TMA, and between t0 and t2 for fluorescein corneal and conjunctival staining. TBUT…

AdultMaleUlls Acomodació i refracciómedicine.medical_specialtyAgingPopulationBaseline levelCornea03 medical and health scienceschemistry.chemical_compound0302 clinical medicineOphthalmologymedicineHumansProspective StudiesFluoresceineducationDisposable EquipmentVision OcularOsmoleeducation.field_of_studyOsmotic concentrationbusiness.industryOsmolar ConcentrationEquipment DesignPresbyopiaMiddle AgedContact Lenses HydrophilicTear osmolarityeye diseasesÒptica Aparells i instrumentsContact lensOphthalmologyTear meniscuschemistryPatient SatisfactionTears030221 ophthalmology & optometryDry Eye SyndromesFemalesense organsbusinessConjunctiva030217 neurology & neurosurgeryFollow-Up Studies
researchProduct

Stereoacuity After Refractive Lens Exchange With AcrySof ReSTOR Intraocular Lens Implantation

2009

Purpose: To evaluate stereoacuity before and after refractive lens exchange (RLE) with AcrySof ReSTOR intraocular lens (IOL) implantation. Methods: Stereoacuity was measured using the Titmus stereotest at 40 cm under photopic conditions (85 cd/m 2 ) before and after RLE with bilateral AcrySof ReSTOR Natural (SN60D3 model) implantation in 30 hyperopic eyes of presbyopes with low astigmatism (⩽1.00 diopter [D]). Stereoacuity measurements after implantation were compared with those found before surgery. Results: Stereoacuity was unchanged after RLE with pseudoaccommodative IOL implantation. In this population of non-cataractous hyperopes with excellent preoperative stereoacuity (46.42±1.36 se…

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentPopulationVisual AcuityIntraocular lensAstigmatismOpticsLens Implantation IntraocularOphthalmologymedicineHumanseducationDioptreLenses IntraocularDepth PerceptionVision Binoculareducation.field_of_studyPhacoemulsificationbusiness.industryPresbyopiaPresbyopiaPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesStereoscopic acuityOphthalmologyHyperopiaFemaleSurgerymedicine.symptombusinessJournal of Refractive Surgery
researchProduct

Comparison of Macular Thickness in Patients with Keratoconus and Control Subjects Using the Cirrus HD-OCT

2014

Purpose.The aim of the present study was to compare macular thickness in patients with keratoconus (KC) with macular thickness in healthy subjects.Subjects and Methods.Twenty-six patients with KC and 52 control subjects were included. The macular structure was evaluated using a Zeiss Cirrus HD-OCT. The scan pattern used was 512 × 128, which covers an area of approximately 6 × 6 mm of the retina. The cube volume was assessed as well as macular thickness in each of the 9 sectors defined by the software.Results.The mean signal strength was significantly lower in the KC group (mean 8.4, range 6–10) compared with the control group (mean 9.7, range 7–10),P&lt;0.0001(unpairedt-test). There were no…

AdultMaleKeratoconusmedicine.medical_specialtygenetic structuresArticle Subjectlcsh:MedicineKeratoconusAge and sexGeneral Biochemistry Genetics and Molecular BiologySignal strengthOphthalmologyHumansMedicineMacula LuteaIn patientGeneral Immunology and Microbiologybusiness.industrylcsh:RHealthy subjectsGeneral MedicineMiddle AgedControl subjectsmedicine.diseaseeye diseasesCase-Control StudiesOptometryFemaleCirrussense organsbusinessTomography Optical CoherenceResearch ArticleBioMed Research International
researchProduct

Use of digital displays and ocular surface alterations: A review.

2020

Digital display use has been accepted to be implicated as a contributing factor for dry eye disease (DED). Abnormal blinking during computer operation, including a reduced blink rate and an incomplete eyelid closure, increased palpebral fissure as consequence of high visualization angles, and meibomian gland dysfunction associated to long-term display use, are behind the increased prevalence of dry eye signs and symptoms found in digital display users. Previous research reveals significant reductions in tear volume and stability, alterations in tear film composition, including increased osmolarity, inflammatory cytokines, oxidative stress markers and reduced mucin secretion, eyelid abnormal…

medicine.medical_specialtygenetic structuresSigns and symptomsDiseaseTear volume03 medical and health sciences0302 clinical medicineOphthalmologyMedicineHumansBlinkingbusiness.industryComputer vision syndromeMeibomian Glandsmedicine.diseaseeye diseasesOphthalmologymedicine.anatomical_structurePalpebral fissureTears030221 ophthalmology & optometryEyelid DiseasesDry Eye SyndromesFemalesense organsEyelidComputer OperationbusinessOcular surfaceConjunctiva030217 neurology & neurosurgeryThe ocular surface
researchProduct

Retinal Straylight Before and After Penetrating Keratoplasty in an Eye with a Post-Herpetic Corneal Scar

2008

Objetivo: Estudio in vivo de la luz dispersa que alcanza la retina en un paciente antes y despues de someterse a una queratoplastia penetrante (o sus siglas en ingles, PKP). Metodos: En un paciente varon de 65 anos con una ulcera corneal herpetica se midio la proporcion de luz dispersa que alcanza la retina tanto antes como despues de una PKP, utilizando para ello un metodo psicometrico denominado "de comparacion por compensacion" («Compensation comparison method», C-Quant straylightmeter, Oculus GmbH, Alemania). Resultados: La cantidad de luz dispersa que alcanza la retina medida antes de la cirugia fue elevada en comparacion con los valores obtenidos en estudios previos en sujetos normale…

luz dispersa que llega a la retina0303 health sciencesmedicine.medical_specialtyretinal straylightvisual performancegenetic structuresbusiness.industryCase Reportkeratoplastycalidad visualeye diseasesqueratoplastia03 medical and health sciences0302 clinical medicinelcsh:Ophthalmologylcsh:RE1-994Ophthalmology030221 ophthalmology & optometrymedicinelcsh:QC350-467businesslcsh:Optics. LightCorneal Scar030304 developmental biologyOptometryJournal of Optometry
researchProduct

Confocal scanning laser ophthalmoscopy versus modified conventional fundus camera for fundus autofluorescence.

2016

Fundus autofluorescence (FAF) is a noninvasive imaging method to detect fundus endogenous fluorophores, mainly lipofuscin located in the retinal pigment epithelium (RPE). The FAF provides information about lipofuscin distribution and RPE health, and consequently an increased accumulation of lipofuscin has been correlated with ageing and development of certain retinal conditions. Areas covered: An exhaustive literature search in MEDLINE (via OVID) and PUBMED for articles related to ocular FAF in retinal diseases and different devices used for acquiring FAF imaging was conducted. Expert commentary: This review aims to show an overview about autofluorescence in the RPE and the main devices use…

0301 basic medicinemedicine.medical_specialtygenetic structuresFundus OculiBiomedical EngineeringFundus (eye)Fundus cameraFluorescenceLipofuscin03 medical and health scienceschemistry.chemical_compound0302 clinical medicineOpticsOphthalmologymedicinePhotographyHumansFluorescent DyesRetinal pigment epitheliumbusiness.industryLasersRetinalGeneral Medicineeye diseasesFundus autofluorescenceConfocal scanning laser ophthalmoscopyOphthalmoscopyAutofluorescence030104 developmental biologymedicine.anatomical_structurechemistry030221 ophthalmology & optometrySurgerysense organsbusinessExpert review of medical devices
researchProduct

Contrast sensitivity after LASIK flap creation with a femtosecond laser and a mechanical microkeratome

2007

ABSTRACT PURPOSE: To compare the effects on contrast sensitivity of the IntraLase femtosecond laser for flap creation (IntraLASIK) and standard LASIK for myopia. METHODS: Two hundred eyes of 100 consecutive patients underwent LASIK treatment using the VISX S2 laser system. The femtosecond laser (15 kHz IntraLase) was used for flap creation in 100 eyes (50 patients) and a mechanical microkeratome (Carriazo-Barraquer) was used in 100 eyes (50 patients). Best spectacle-corrected contrast sensitivity was measured before and 6 months postoperatively in the IntraLASIK and mechanical LASIK groups. The IntraLASIK and mechanical LASIKinduced changes in contrast sensitivity were compared under photop…

Adultmedicine.medical_specialtygenetic structuresMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituSurgical Flapslaw.inventionContrast SensitivitylawMicrokeratomeOphthalmologymedicineHumansContrast (vision)media_commonbusiness.industryLASIKEquipment DesignRefractive ErrorsLasereye diseasesRefractive Surgical ProceduresSurgeryOphthalmologyTreatment OutcomeFemtosecondSurgerysense organsbusinessSensitivity (electronics)Follow-Up StudiesPhotopic vision
researchProduct

Visual performance with simultaneous vision multifocal contact lenses.

2011

Purpose:  The aim was to assess visual performance after PureVision high addition multifocal contact lens (PM) fitting through contrast sensitivity measured under different illumination levels for both distance and near. Methods:  In a cross-over study, 20 presbyopic patients were randomly assigned to PM or spectacles. Near contrast sensitivity was measured with the Vistech VCTS 6500 system. Distance contrast sensitivity and distance visual acuity (VA) were measured with the Functional Vision Analyser under photopic (85 cd/m2) and mesopic (3.0 cd/m2) conditions, the latter also under two levels of induced glare: 1.0 lux and 28 lux. Near VA was measured by logMAR charts under approximately 8…

Adultmedicine.medical_specialtyDistance visual acuitygenetic structuresMesopic visionContact Lensesmedia_common.quotation_subjectVisual AcuityContrast SensitivityOpticsOphthalmologymedicineContrast (vision)Humansmedia_commonMathematicsMonocularCross-Over Studiesbusiness.industryGlare (vision)Accommodation OcularPresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseeye diseasesContact lensOphthalmologyTreatment OutcomebusinessOptometryPhotopic visionFollow-Up StudiesClinicalexperimental optometry
researchProduct

Objective measurement of intraocular forward light scatter using Hartmann-Shack spot patterns from clinical aberrometers. Model-eye and human-eye stu…

2007

Purpose To apply software-based image-analysis tools to objectively determine intraocular scatter determined from clinically derived Hartmann-Shack patterns. Setting Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom, and Department of Optics, University of Valencia, Valencia, Spain. Methods Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartmann-Shack analyzer (WASCA, Zeiss/Meditec). Three scatter values, as the maximum standard deviation within a lenslet for all lenslets in the pattern, were obtained in 6 model eyes and 10 human eyes. In the model-eye sample, patterns were obtained in 4 sessi…

AdultMaleLightPsychometricsIntraclass correlationLensletDiagnostic Techniques OphthalmologicalEyeRefraction OcularModels BiologicalSensitivity and SpecificityStandard deviationOpticsmedicineImage Processing Computer-AssistedHumansScattering RadiationMathematicsbusiness.industryObjective measurementCentroidReproducibility of ResultsSmall sampleRepeatabilitySensory SystemsOphthalmologymedicine.anatomical_structureOptometrySurgeryHuman eyeFemalebusinessJournal of cataract and refractive surgery
researchProduct

Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens

2007

To examine the optical quality of healthy presbyopic eyes before and after implantation of the pseudoaccommodating AcrySof ReSTOR Natural intraocular lens (IOL) (Alcon Laboratories) by measuring visual acuity and wavefront aberrations.University of Valencia, Fernández-Vega Ophthalmological Institute, Valencia, Spain.Monocular refraction and photopic distance (6 m) and near (0.33 m) visual acuities were determined before and after clear lens extraction with bilateral AcrySof ReSTOR Natural IOL implantation in 30 hyperopic eyes (+0.50 to +4.00 diopters [D]) of presbyopic patients with low astigmatism (or = 1.00 D). Postsurgical binocular visual acuity was measured over a range of effective di…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismProsthesis DesignPupillaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyLens CrystallinemedicineHumansDioptreLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryAccommodation OcularPresbyopiaPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyHyperopiaOptometryFemaleSurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

An Emerging Method to Assess Tear Film Spread and Dynamics as Possible Tear Film Homeostasis Markers

2021

This study aims to assess the performance of an analysis method to measure in vivo the movement speed of tear film particles post-blink as a measure of tear film spreading. Ocular surface parameter...

AdultMaleMaterials scienceAdolescentgenetic structuresMeasure (physics)Young Adult03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicineHomeostasisHumansAnalysis methodAgedAged 80 and overBlinkingDynamics (mechanics)Meibomian GlandsMiddle AgedHealthy Volunteerseye diseasesSensory SystemsOphthalmologyTears030221 ophthalmology & optometryDry Eye SyndromesFemalesense organsOcular surface030217 neurology & neurosurgeryBiomedical engineeringCurrent Eye Research
researchProduct

Reliability results of straylight measurements using the C-Quant

2008

Purpose Assessment of repeatability and reproducibility of straylight measures with the C-Quant straylightmeter (Oculus AG, Germany), effect of age on reliability measures and correlation of measures determined with new methods of scatter determination. Methods Results from different studies will be presented. For repeatability assessment, 20 eyes (age 26.9±2.7 years) were examined with the C-Quant, taking 10 consecutive readings. 5 subjects were also examined on 5 consecutive days to assess reproducibility. Repeated measures from 84 subjects, age range 19-86 years, were analysed to assess the effect of patient’s age. Software was developed to quantify scatter from centroid patterns obtaine…

Reproducibilitymedicine.medical_specialtybusiness.industryHealthy subjectsRepeated measures designSmall sampleGeneral MedicineRepeatabilityAudiologyCorrelationOphthalmologyOpticsmedicinebusinessReliability (statistics)Acta Ophthalmologica
researchProduct

Corneal Thickness Response after Anesthetic Eye Drops: Our Own Results and Meta-Analysis.

2017

We aimed to test if there are different patterns in the central corneal thickness (CCT) response after instilling oxybuprocaine anesthetic eye drops and also to determine whether there is a significant change in the CCT. CCT was measured in 60 eyes of 60 healthy subjects before and during the hour after oxybuprocaine 0.4% eye drops were instilled. In addition, a systematic review and meta-analysis were carried out in order to answer the following PICO (patient, intervention, comparison, and outcome) question: What effect do anesthetic eye drops have on CCT values? We found no significant changes in the mean CCT values during the hour’s observation (ANOVA, p=0.209), and the meta-analysis rev…

AdultMalemedicine.medical_specialtyArticle Subjectgenetic structureslcsh:MedicineGeneral Biochemistry Genetics and Molecular BiologyCornea03 medical and health sciences0302 clinical medicineOphthalmologyMedicineHumans030212 general & internal medicineProspective StudiesOxybuprocaineAnesthetics LocalGeneral Immunology and Microbiologybusiness.industrylcsh:RHealthy subjectsGeneral Medicineeye diseasesHealthy VolunteersMeta-analysisAnesthetic030221 ophthalmology & optometryFemaleAnalysis of variancesense organsOphthalmic SolutionsbusinessProcainemedicine.drugResearch ArticleBioMed research international
researchProduct

Retinal straylight in patients with monofocal and multifocal intraocular lenses

2007

Purpose To determine the differences in retinal straylight perceived by patients with monofocal intraocular lenses (IOLs) and patients with multifocal IOLs. Setting Vissum-Instituto de Oftalmologico de Alicante, Alicante, Spain. Methods In this prospective study, contrast sensitivity and retinal straylight were measured prospectively 6 months postoperatively in 67 eyes of 40 patients with a monofocal or multifocal IOL. In the monofocal group, a ThinOptX IOL (ThinOptX, Inc.) was implanted in 12 eyes and an Acri.Smart 48 S IOL (Acri.Tec) in 20 eyes. In the multifocal IOL group, a ReZoom IOL (Advanced Medical Optics) was implanted in 13 eyes and a ReSTOR IOL (Alcon Laboratories) in 22 eyes. Re…

Miosismedicine.medical_specialtyLightPseudophakiagenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectIntraocular lensRetinaPupilGlareContrast Sensitivitychemistry.chemical_compoundLens Implantation IntraocularOphthalmologymedicineHumansScattering RadiationContrast (vision)Prospective StudiesAgedmedia_commonAged 80 and overLenses IntraocularPhacoemulsificationbusiness.industryGlare (vision)RetinalPhacoemulsificationMiddle AgedMultifocal intraocular lensequipment and supplieseye diseasesSensory SystemsOphthalmologychemistryOptometrySurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Evaluation of the anterior chamber angle in keratoconus and normal subjects.

2015

To evaluate the anterior chamber angle in keratoconus eyes by use of the Visante™ OCT and Orbscan™ II.Anterior chamber angle was measured with the Visante™ OCT and Orbscan™ II in 52 subjects, 26 KC subjects and 26 age and control subjects.When comparing the nasal and temporal angles obtained with the two techniques no correlation was found (R(2) always below 0.01) in either the control subjects or in the KC subjects. Despite this, there was an overall statistically significant difference in mean anterior chamber angles (p0.001) between Visante™ OCT and Orbscan™ II. There was no statistical difference (p0.05) between nasal and temporal anterior chamber angles when comparing controls and KC s…

AdultMaleKeratoconusmedicine.medical_specialtyKeratoconusSensitivity and SpecificityAnterior chamber angleAnterior Eye SegmentReference ValuesOphthalmologymedicineHumansOrbscan iiSlit Lampbusiness.industrySignificant differenceCorneal TopographyReproducibility of ResultsGeneral Medicinemedicine.diseaseControl subjectsOphthalmologyOptometryFemalebusinessTomography Optical CoherenceOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Systemic, environmental and lifestyle risk factors for dry eye disease in a mediterranean caucasian population

2022

Abstract Objectives To assess systemic, environmental and lifestyle risk factors for dry eye disease (DED) in a Mediterranean Caucasian population. Methods A cross-sectional study was performed on 120 Caucasian participants aged between 18 and 89 years (47.0 ± 22.8 years). Medical history, information regarding environmental conditions and lifestyle, Ocular Surface Disease Index, Dry Eye Questionnaire-5, non-Invasive (Oculus Keratograph 5 M) breakup time, tear film osmolarity and ocular surface staining parameters were assessed in a single clinical session to allow DED diagnosis based on the guidelines of the Tear Film and Ocular Surface Society Dry Eye Workshop II Diagnostic Methodology Re…

Adultmedicine.medical_specialtyAdolescentDiseaseLogistic regressionYoung AdultRisk FactorsCaffeineInternal medicineEpidemiologyHumansMedicineOcular Surface Disease IndexMedical historyRisk factorLife StyleAgedAged 80 and overUnivariate analysisbusiness.industryGeneral MedicineMiddle Agedmedicine.diseaseMenopauseOphthalmologyCross-Sectional StudiesAnti-Anxiety AgentsTearsDry Eye SyndromesFemalebusinessOptometryContact Lens and Anterior Eye
researchProduct

Contrast sensitivity after refractive lens exchange with diffractive multifocal intraocular lens implantation in hyperopic eyes

2008

Contrast Test chart at distance and near under 3 luminance levels (85.0 cd/m 2 , 5.0 cd/m 2 , and 2.5 cd/m 2 ) before and after RLE with bilateral AcrySof ReSTOR IOL implantation in 30 hyperopic eyes with presbyopia and low astigmatism (%1.0 diopter). Results after surgery were compared with those before surgery. RESULTS: Six months postoperatively, the mean residual spherical equivalent refractive error was 0.21 diopter G 0.19 (SD). The best corrected distance and near visual acuities were comparable to those before surgery. For distance vision, the safety index was 1.02 and the efficacy index was 0.91. For near vision, the values were 1.04 and 1.02, respectively. There were no statistical…

Refractive errormedicine.medical_specialtygenetic structuresbusiness.industrymedia_common.quotation_subjectmedicine.medical_treatmentIntraocular lensPresbyopiaMultifocal intraocular lensAstigmatismmedicine.diseaseeye diseasesSensory SystemsVision disorderOphthalmologyOphthalmologymedicineContrast (vision)Surgerymedicine.symptombusinessDioptremedia_commonJournal of Cataract and Refractive Surgery
researchProduct

Evaluation of the MGDRx eyebag treatment in young and older subjects with dry eye symptoms

2021

Summary Objectives This study aims to evaluate the relationship between application of the MGDRx thermal eyebag and dry eye signs and symptoms in young and older subjects and to compare the results between the two groups. Methods Thirty young, healthily volunteers between 18 and 31 years of age (23.95 ± 3.94 years) and thirty older subjects between 61 and 90 years of age (77.97 ± 8.11 years) participated in this study. Ocular surface parameters were assessed using the Oculus Keratograph 5 M, following the guidelines of the Tear Film and Ocular Surface Dry Eye Workshop II Diagnostic Methodology report. Only subjects with a positive score on at least one questionnaire and an initial Non-Invas…

Adultmedicine.medical_specialtySigns and symptomsYoung AdultSubjective improvementSurveys and QuestionnairesInternal medicinemedicineHumansTelangiectasiaVolunteerMassagebusiness.industryEyelidsMeibomian GlandsLipidseye diseasesTreatment periodOphthalmologymedicine.anatomical_structureTearsMixed-design analysis of varianceDry Eye Syndromessense organsEyelidmedicine.symptombusinessJournal Français d'Ophtalmologie
researchProduct

Spotlight on fundus autofluorescence.

2018

Fundus autofluorescence (FAF) imaging is based on the fluorescence from ocular endogenous fluorophores located in the retinal pigment epithelium and choroid, mainly lipofuscin and melanin. It is a noninvasive technique that provides information about the spatial distribution of lipofuscin/melanin and retinal pigment epithelium health status. An overview about the fluorophores responsible for FAF imaging and the usefulness of FAF imaging in the noninvasive assessment and monitoring of retinal diseases, such as age-related macular degeneration, diabetic retinopathy, diabetic macular edema, central serous chorioretinopthy, retinitis pigmentosa and retinal dystrophies, are discussed in this rev…

medicine.medical_specialtygenetic structuresReviewLipofuscinchemistry.chemical_compoundOphthalmologyRetinitis pigmentosamedicinelipofuscinRetinal pigment epitheliumfundus autofluorescencebusiness.industrynear-infrared fundus autofluorescenceshort-wavelength fundus autofluorescenceRetinalDiabetic retinopathyMacular degenerationmedicine.diseaseSensory Systemseye diseasesmelaninOphthalmologymedicine.anatomical_structurechemistryChoroidsense organsbusinessRetinal DystrophiesClinical optometry
researchProduct

OCT for Assessing Artificial Tears Effectiveness in Contact Lens Wearers

2011

PURPOSE: To apply a commercially available high-resolution spectral domain optical coherence tomographer (SOCT) to assess the change in tear volume after application of a new artificial tears formulation specifically developed for contact lens (CL) users. METHODS: Twenty OD from young healthy CL wearers (mean age, 24.7 ± 3.5 years) with refractive errors ranging from -0.75 to -2.50 D (mean, -1.56 ± 0.69 D) were examined. All subjects were fitted with Focus Dailies CL (Ciba Vision), and two drops of Blink Contacts (AMO), lubricating formulation specifically developed for CL wearers, were instilled after baseline measures. Tear meniscus volume (TMV) was measured immediately after and 1 min, 1…

Adultmedicine.medical_specialtyContact Lensesmedicine.medical_treatmentMeniscus (anatomy)Tear volumeYoung AdultRegular distributionOphthalmologyImage Processing Computer-AssistedHumansMedicinebusiness.industryRepeated measures designContact Lenses HydrophilicRefractive ErrorsContact lensOphthalmologyArtificial tearsmedicine.anatomical_structureTear meniscusOftalmologíaDry Eye SyndromesEyelidOphthalmic SolutionsbusinessTomography Optical CoherenceFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

Book Review

2021

media_common.quotation_subjectLibrary scienceArtEye careOptometrymedia_commonJournal of Optometry
researchProduct

Performance of a new device for the clinical determination of light discomfort

2020

PURPOSE To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was assessed by means of within-subject standard deviation, coefficient of variation (CoV), and intraclass correlation coefficient (ICC). Repeated measures ANOVA, Kruskal-Wallis, and correlation analysis were applied to test for differences between repeated measures, and effect of age on reliability. RESULTS Discomfort thresholds obtained are well distributed across the light intensity…

AdultMalemedicine.medical_specialtyLightIntraclass correlationCoefficient of variationBiomedical Engineering030204 cardiovascular system & hematologyAudiologyStandard deviationYoung Adult03 medical and health sciences0302 clinical medicineHumansMedicineReliability (statistics)AgedReproducibilitybusiness.industryReproducibility of ResultsRepeated measures designGeneral MedicineRepeatabilityMiddle AgedLight intensityFemaleSurgerybusiness030217 neurology & neurosurgeryExpert Review of Medical Devices
researchProduct

Visual and optical performance with the ReZoom multifocal intraocular lens

2011

Purpose This study evaluated visual acuity, contrast sensitivity, and wavefront aberrations after refractive multifocal intraocular lens (IOL) implantation. Methods A prospective study comprising 174 eyes of 87 patients who had bilateral implantation of a multifocal IOL was carried out. A control group of 100 eyes of 50 age-matched patients with a monofocal IOL was used for comparison. Uncorrected and corrected distance and near visual acuity, contrast sensitivity (CS), and wavefront analysis (Hartmann-Shack) was performed 6 months after surgery. Contrast sensitivity was tested for distance and near under mesopic (2 cd/m2) and photopic conditions (90 cd/m2). Results Distance photopic CS was…

Malemedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectVisual AcuityProsthesis DesignRefraction OcularContrast SensitivityLens Implantation IntraocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonAged 80 and overLenses IntraocularWavefrontVision Binocularbusiness.industryAberrometryGeneral MedicineMiddle AgedMultifocal intraocular lenseye diseasesOphthalmologyFemalemedicine.symptombusinessEuropean Journal of Ophthalmology
researchProduct

Corneal Aberrations, Contrast Sensitivity, and Light Distortion in Orthokeratology Patients: 1-Year Results.

2016

Purpose. To evaluate the corneal higher-order aberrations (HOA), contrast sensitivity function (CSF), and light distortion (LD) in patients undergoing orthokeratology (OK). Methods. Twenty healthy subjects (mean age: 21.40 ± 8 years) with mean spherical equivalent refractive error M = −2.19 ± 0.97 D were evaluated at 1 day, 1 month, and 1 year after starting OK treatment. Monocular LD, photopic monocular CSF, and corneal HOA for 6 mm pupil size were measured. Results. LD showed an increase after the first night (𝑝 0.05). Spherical-like, coma-like, and secondary astigmatism HOA RMS increased significantly (𝑝 ≤ 0.022) from baseline to 1-month visit, remaining unchanged over the follow-up. C…

Refractive errormedicine.medical_specialtyArticle Subjectgenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectSpherical equivalent01 natural sciences010309 optics03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyOphthalmology0103 physical sciencesmedicineContrast (vision)In patientmedia_commonScience & Technologybusiness.industryOrthokeratologyPupil sizeHealthy subjectsmedicine.diseaseOphthalmologylcsh:RE1-994030221 ophthalmology & optometryOptometrybusinessPhotopic visionResearch ArticleJournal of ophthalmology
researchProduct

The posterior chamber phakic refractive lens (PRL): a review

2012

Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on…

Phakic Intraocular Lensesmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentVisual performanceOptical qualityReviewAstigmatismRefraction OcularPhakic intraocular lensPhakic refractive lens (PRL)CataractPupilEndophthalmitisLens Implantation IntraocularCataractsOphthalmologyRefractive surgeryMyopiamedicineHumansRefractive surgeryÓpticaPosterior chamber phakic intraocular lensbusiness.industryPatient SelectionEquipment Designmedicine.diseaseeye diseasesOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Posterior Capsule of the LensOptometrysense organsbusinessEye
researchProduct

Light distortion of soft multifocal contact lenses with different pupil size and shape

2020

Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…

AdultMaleLight distortionbusiness.product_categorygenetic structuresCiências Naturais::Ciências Físicas:Ciências Físicas [Ciências Naturais]Visual AcuityRefraction OcularPupillaw.invention03 medical and health sciences0302 clinical medicineOpticslawDistortionNon-circular pupilsHumansMultifocal lensesMathematicsScience & Technologybusiness.industryPupil sizePupilMean ageEquipment DesignGeneral MedicineRadiusMiddle AgedContact Lenses HydrophilicRefractive ErrorsHealthy Volunteerseye diseasesContact lensLens (optics)Ophthalmology030221 ophthalmology & optometryMultifocal contact lensesFemalesense organsbusiness030217 neurology & neurosurgeryOptometryContact Lens and Anterior Eye
researchProduct

Diagnostic Capability of a New Objective Method to Assess Meibomian Gland Visibility

2021

SIGNIFICANCE The diagnosis of dry eye disease and meibomian gland dysfunction (MGD) is challenging. Measuring meibomian gland visibility may provide an additional objective method to diagnose MGD. PURPOSE This study aimed to evaluate the ability of new metrics to better diagnose MGD, based on measuring meibomian gland visibility. METHODS One hundred twelve healthy volunteers (age, 48.3 ± 27.5 years) were enrolled in this study. Ocular surface parameters were measured using the Oculus Keratograph 5M (Oculus GmbH, Wetzlar). Subjects were classified according to the presence or absence of MGD. New metrics based on the visibility of the meibomian glands were calculated and later compared betwee…

Adultmedicine.medical_specialtyMeibomian glandPixel intensityLogistic regressionYoung AdultOphthalmologyTear meniscus heightmedicineHumansMeibomian Gland DysfunctionAgedLid marginReceiver operating characteristicbusiness.industryVisibility (geometry)Meibomian GlandsObjective methodMiddle AgedOphthalmologymedicine.anatomical_structureTearsEyelid DiseasesDry Eye Syndromessense organsbusinessOptometryOptometry and Vision Science
researchProduct

Clinical Impact of a Spontaneous Decentration of a Phakic Refractive Lens

2011

PURPOSE To evaluate the clinical impact and possible causes of a spontaneous decentration of a phakic refractive lens (PRL) implanted in a highly myopic eye, and analyzing the visual, refractive, and aberrometric outcome as well as the possible causes for this phenomenon. METHODS The description of a case of bilateral high myopia corrected by implantation with the phakic intraocular lens (pIOL) PRL (Carl Zeiss Meditec, Germany) is presented and documented. Both eyes had similar anatomical configuration, and therefore, a pIOL (Model 101) with the same size was implanted without any associated intraoperative complication. Clinical outcomes were evaluated during a 3-month follow-up. RESULTS Im…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyDistance visual acuitygenetic structuresVisual AcuityComa (optics)Anatomical configurationRefraction OcularPhakic intraocular lensPostoperative ComplicationsOphthalmologyAberrometryMyopiamedicineHumansbusiness.industryLens SubluxationRefractive lensSubjective refractioneye diseasesOphthalmologySpherical aberrationsense organsbusinessFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

A comparison of the Canon TX-20P™ non-contact tonometer and pachymeter in healthy eyes

2012

Background: The aim of this study was to compare the intraocular pressure (IOP) and the central corneal thickness (CCT) measurements obtained with the Canon TX-20P™ with IOP measured with Goldmann applanation tonometer (GAT) and the CCT measured with ultrasound (US) pachymetry in healthy eyes. Methods: Thirty one healthy voluntary subjects participated in the study, age ranging from 16 to 81 years (mean age 50.9 years). In total 58 eyes were selected for analysis. All measurements were performed by the same examiner. The measurements were taken in the same order in all subjects: Canon IOP and CCT, Goldmann IOP and US CCT. Results: A strong correlation was found between IOP for both CCT comp…

Applanation tonometryIntraocular pressuremedicine.medical_specialtygenetic structuresbusiness.industrySignificant differenceGoldmann Applanation TonometerMean ageNon contact tonometereye diseasesOphthalmologyMedicineOptometrysense organsbusinessInternational Journal of Ophthalmic Practice
researchProduct

Comparison of partial coherence interferometry and ultrasound for anterior segment biometry.

2008

To assess the performance of a partial coherence interferometry (PCI)-based device for the determination of anterior segment biometry.Clinica Centrofama, Cartagena, Murcia, Spain.Central corneal thickness (CCT), anterior chamber depth (ACD), and lens thickness (LT) were measured with the ACMaster PCI anterior segment biometer and an Echoscan US-1800 ultrasound (US) biometer/pachymeter with and without cycloplegia. To determine the precision of the instruments, the same examiner took 30 consecutive CCT, ACD, and LT measurements in a single subject under the same conditions and with and without cycloplegia. The same measurements were performed in additional subjects.Twenty-one eyes (16 subjec…

AdultMalemedicine.medical_specialtyMydriaticsMaterials scienceBiometrygenetic structuresLightAnterior ChamberDiagnostic Techniques OphthalmologicalEyeCorneaLens thicknessOphthalmologyLens CrystallinemedicineHumansBody Weights and Measuresbusiness.industryUltrasoundReproducibility of ResultsCycloplegiaPupileye diseasesSensory SystemsSurgeryOphthalmologyInterferometrySoundPartial coherence interferometrySurgeryFemalesense organsmedicine.symptombusinessPartial coherenceJournal of cataract and refractive surgery
researchProduct

Pilot Study on Visual Function and Fundus Autofluorescence Assessment in Diabetic Patients.

2015

Purpose. Evaluate optimized fundus autofluorescence (FAF) imaging in early stages of diabetic retinopathy (DR) and relate findings with conventional colour fundus imaging and visual function in diabetic patients and control subjects.Materials and Methods. FAF and colour images were obtained using the CR-2 Plus digital nonmydriatic retinal camera in seven diabetic patients and thirteen control subjects. Visual-Functioning Questionnaire-25 (VFQ-25) and Diabetes Self-Management Questionnaire (DSMQ) were used to assess the quality of life and diabetes self-care. Contrast sensitivity function (CSF) was evaluated with the Vistech 6500 chart.Results. FAF and optimized-FAF imaging showed more retin…

medicine.medical_specialtyArticle Subjectgenetic structuresmedia_common.quotation_subjectFundus (eye)03 medical and health scienceschemistry.chemical_compound0302 clinical medicinelcsh:OphthalmologyOphthalmologyDiabetes mellitusmedicineContrast (vision)030212 general & internal medicinemedia_commonRetinal pigment epitheliumbusiness.industryRetinalDiabetic retinopathymedicine.diseaseFundus autofluorescenceOphthalmologymedicine.anatomical_structurechemistrylcsh:RE1-994Visual function030221 ophthalmology & optometryOptometrybusinessResearch ArticleJournal of ophthalmology
researchProduct

Comparison of higher order aberrations measured by NIDEK OPD-Scan dynamic skiascopy and Zeiss WASCA Hartmann-Shack aberrometers.

2008

&lt;h4&gt;PURPOSE&lt;/h4&gt;&lt;p&gt;To compare the measurement of wavefront aberrations in non-cyclopleged human eyes with Hartmann-Shack and dynamic skiascopy wavefront analyzers.&lt;/p&gt; &lt;h4&gt;METHODS&lt;/h4&gt;&lt;p&gt;Eighty eyes of 40 healthy young adults (19 men, 21 women; mean age 20.8±2.5 years) with refractive errors ranging from +1.50 to –9.75 diopters (D) sphere and up to 1.75 D cylinder (mean spherical equivalent refraction –2.12±2.69 D) were examined with the Zeiss/Meditec WASCA and NIDEK OPD-Scan wavefront analyzers and with the Nippon SRW5000 binocular, open-field autorefractor without the instillation of antimuscarinic agents. Three measurements were taken with each s…

WavefrontAdultMalegenetic structuresbusiness.industrymedicine.medical_treatmentReproducibility of ResultsClinical settingsDiagnostic Techniques OphthalmologicalRefraction OcularRefractive Errorseye diseasesOphthalmologyAberrations of the eyeOpticsRefractive surgerymedicineOptometryHumansSurgeryFemalebusinessNatural stateMathematicsWavefront analysisJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Effects of Ageing on the Anterior Segment of the Eye Structure and Function

2018

[Excerpt] The world will soon have more aged people than children and more people at extreme old age than ever before [1]. Improving quality of life as well as reducing severe disability due to age-related problems has become key for the health systems worldwide. The ageing of the world population has both structural and functional consequences for the human visual system; changes due to ageing occur in all the structures of the eye causing a variety of effects. Over the last few years, great advances in ophthalmic instrumentation allow the determination of ocular parameters to a level of detail without precedent. Such advances allowresearcherstodevelopspecificdevicesforvisualcorrection and r…

medicine.medical_specialtyScience & TechnologyArticle SubjectCiências Naturais::Ciências Físicasbusiness.industrymedia_common.quotation_subjectMEDLINE030204 cardiovascular system & hematology3. Good health03 medical and health sciencesOphthalmologyEditorial0302 clinical medicineText miningPhysical medicine and rehabilitationlcsh:Ophthalmologylcsh:RE1-994AgeingEye structureMedicineFunction (engineering)business030217 neurology & neurosurgerymedia_commonJournal of Ophthalmology
researchProduct

Systemic, environmental and lifestyle risk factors for dry eye disease in a mediterranean caucasian population

2021

Objectives: To assess systemic, environmental and lifestyle risk factors for dry eye disease (DED) in a Mediterranean Caucasian population. Methods: A cross-sectional study was performed on 120 Caucasian participants aged between 18 and 89 years (47.0 ± 22.8 years). Medical history, information regarding environmental conditions and lifestyle, Ocular Surface Disease Index, Dry Eye Questionnaire-5, non-Invasive (Oculus Keratograph 5 M) breakup time, tear film osmolarity and ocular surface staining parameters were assessed in a single clinical session to allow DED diagnosis based on the guidelines of the Tear Film and Ocular Surface Society Dry Eye Workshop II Diagnostic Methodology Report. A…

researchProduct

“In situ” corneal and contact lens thickness changes with high resolution OCT

2012

Purpose: To show the utility of high resolution spectral domain optical coherence tomography (HR SOCT) for the in situ evaluation of epithelial, stromal and contact lens (CL) thickness changes under closed-eye conditions without lens removal. Settings: Clinical and Experimental Optometry Research Lab, University of Minho, Portugal. Methods: Eight young healthy patients wore a thick soft CL during 90 minutes under closed-eye conditions and measures of epithelial and stromal corneal thickness were obtained at regular intervals using a HR SOCT (Copernicus HR, Optopol Tech. SA, Poland). Results: Minimal changes in epithelial thickness were detected with a transient statistically significant inc…

Corneacontact lensesScience & Technologygenetic structuresOCTepithelial thicknessCoherence tomographysense organsedemaeye diseasesstromal thickness
researchProduct

Corrigendum to “Short-Term Changes in Light Distortion in Orthokeratology Subjects”

2015

Article Subject
researchProduct