0000000000160672

AUTHOR

Wolfgang Schreiber

showing 56 related works from this author

MR-Perfusionsbildgebung des Herzens mit TrueFISP

2001

OBJECTIVE Development and test of a saturation-recovery TrueFISP (SR-Trufi) pulse sequence for myocardial perfusion MR imaging (MRI) using improved gradient hardware. MATERIAL AND METHODS Measurements were performed on a 1.5 T scanner with prototype gradients (50 mT/m, minimum rise time 300 microseconds). T1-weighted first-pass MRI of Gd-DTPA (0.025 mumol/kg) kinetics in the myocardium was performed using an SR-Trufi pulse sequence (TR/TE/alpha = 2.6 ms/1.4 ms/55 degrees) with a saturation preparation of TD = 30 ms before the TrueFISP readout. Measurements were performed in volunteers (n = 4) and in a pig model of chronic ischemia (n = 1). RESULTS In phantoms, the signal intensity was linea…

Materials sciencemedicine.diagnostic_testbusiness.industryGood imagePulse sequencePig modelMagnetic resonance imagingMr imagingNuclear magnetic resonanceHigh spatial resolutionmedicineRadiology Nuclear Medicine and imagingMyocardial microcirculationNuclear medicinebusinessPerfusionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Controlling diffusion of 3He by buffer gases: a structural contrast agent in lung MRI.

2006

Purpose: To study the influence of admixing inert buffer gases to laser-polarized 3 He in terms of resulting diffusion coefficients and the consequences for image contrast and resolution. Materials and Methods: The diffusion coefficient of 3 He was altered by admixing buffer gases of various molecular weights ( 4 He, N2, and SF6). The influence of the pulse sequence and the diffusion coefficient on the appearance of MRI of (laserpolarized) gases was analyzed by comparison of basic theoretical concepts with demonstrative experiments. Results: Excellent agreement between theoretical description and observed signal in simple gradient echoes was observed. A maximum signal gain can be predicted …

InertMaterials sciencePhantoms ImagingDiffusionPhysics::Medical PhysicsBuffer gasResolution (electron density)Contrast MediaReproducibility of ResultsPulse sequenceImage EnhancementSignalMolecular physicsHeliumSensitivity and SpecificityDiffusion Magnetic Resonance ImagingIsotopesRestricted DiffusionEffective diffusion coefficientHumansRadiology Nuclear Medicine and imagingGasesLungJournal of magnetic resonance imaging : JMRI
researchProduct

Erfahrungen mit einer 3D-Navigatorsequenz zur Koronargefäßdarstellung an einem Hochleistungs-MR-System

2002

Purpose: To evaluate MR coronary angiography using a three-dimensional navigator echo sequence on a MR scanner with a high performance gradient system. Material and Methods: Five healthy volunteers were examined with a 1.5 Tesla MR system, using a high performance prototype gradient system (peak amplitude 50 mT/m, rising time 600 μs). For imaging, a navigated gradient-echo pulse sequence with an in-plane resolution between 0.63 × 0.63 and 0.78 × 0.78 mm 2 was used. Per patient two overlapping slabs were acquired. The number of visualised coronary artery segments was estimated (AHA classification). In addition, signal-to-noise measurements were performed in the ascending aorta at the level o…

Coronary angiographymedicine.medical_specialtybusiness.industryCoronary arteriesmedicine.anatomical_structureLeft coronary arteryNavigator echoRight coronary arterymedicine.arteryAscending aortamedicineRadiology Nuclear Medicine and imagingRadiologybusinessNuclear medicineVolunteerArteryRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Quantification of Regional Intrapulmonary Oxygen Partial Pressure Evolution during Apnea by 3He MRI

1999

We present a new method to determine in vivo the temporal evolution of intrapulmonary oxygen concentrations by functional lung imaging with hyperpolarized (3)Helium ((3)He-->). Single-breath, single-bolus visualization of (3)He--> administered to the airspaces is used to analyze nuclear spin relaxation caused by the local oxygen partial pressure p(O(2))(t). We model the dynamics of hyperpolarization in the lung by rate equations. Based hereupon, a double acquisition technique is presented to separate depolarization by RF pulses and oxygen induced relaxation. It permits the determination of p(O(2)) with a high accuracy of up to 3% with simultaneous flip angle calibration using no additional …

AdultMaleNuclear and High Energy PhysicsApneaSwinePartial PressureBiophysicsAnalytical chemistrychemistry.chemical_elementHyperpolarized Helium 3HeliumBiochemistryOxygenNuclear magnetic resonanceIsotopesFlip angleAnimalsHumansHyperpolarization (physics)LungPhantoms ImagingRelaxation (NMR)DepolarizationPartial pressureCondensed Matter PhysicsMagnetic Resonance ImagingOxygenchemistryLimiting oxygen concentrationJournal of Magnetic Resonance
researchProduct

19F-MRT der Lungenventilation in Atemanhaltetechnik mittels SF6-Gas

2000

Breathhold 19 F-Magnetic Resonance Imaging of Lung Ventilation using SF 6 Gas. Objective: Development of a method to analyze lung ventilation by 19 F-magnetic resonance imaging (MRI) of inspired SF 6 gas during breathhold. Material and Methods: Measurements were performed with a Siemens Magnetom Vision 1.5T scanner using the conventional gradient overdrive. Coronal images of the lung were acquired using ultrafast gradient-echo pulse sequences with TR/TE/α = 1.4 ms/ 0.48 ms/40° without slice selection. With NEX = 200 averages and MA = 32 × 64 raw data matrix, the acquisition time was 9s/image. Higher spatial resolution of 4.7 × 6.3 × 15 mm 3 was obtained with a three-dimensional pulse sequen…

ScannerMaterials sciencebusiness.industryPulse (signal processing)Image qualityPulse sequenceNuclear magnetic resonanceSignal-to-noise ratio (imaging)Slice selectionRadiology Nuclear Medicine and imagingSignal averagingNuclear medicinebusinessImage resolutionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Ein Auswerteprogramm zur quantitativen Untersuchung der Lungenventilation mittels dynamischer MRT von hochpolarisiertem 3He

2004

Purpose: 3 He-MRI is able to visualize the regional distribution of lung ventilation with a temporal and spatial resolution so far unmatched by any other technique. The aim of the study was the development of a new software tool for quantification of dynamic ventilation parameters in absolute physical units. Materials and Methods: During continuous breathing, a bolus of hyperpolarized 3 He (300 ml) was applied at inspiration and a series of 168 coronal projection images simultaneously acquired using a 2D FLASH-sequence. Postprocessing software was developed to analyze the 3 He distribution in the lung. After correction for lung motion, several ventilation parameters (rise time, delay time, …

Normalization (statistics)Pathologymedicine.medical_specialtybusiness.industryComputer sciencemedicine.medical_treatmentlaw.inventionPulmonary function testingSoftwarelawVentilation (architecture)BreathingmedicineLung transplantationRadiology Nuclear Medicine and imagingLung emphysemabusinessImage resolutionBiomedical engineeringRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Functional Evaluation of Emphysema Using Diffusion-Weighted 3Helium-Magnetic Resonance Imaging, High-Resolution Computed Tomography, and Lung Functio…

2004

Purpose: To assess the emphysematous enlargement of distal air-spaces and concomitant large and small airway disease using diffusion-weighted 3 Helium-magnetic resonance imaging (MRI), high-resolution computed tomography (HRCT), and lung function tests (LFT). Methods: Seven patients were examined after single lung transplantation (LTx) and 1 before double LTx for various forms of emphysema. Five patients after double LTx served as controls. Patients were assessed by 3 Helium-MRI (apparent diffusion coefficient [ADC]), HRCT (mean lung density [MLD], emphysema index [El]), and LFT. Results: Transplanted lungs: mean ADC = 0.17 cm 2 /s, MLD = -848 H, El = 22%. Emphysematous lungs: mean ADC = 0.…

Malemedicine.medical_specialtyHigh-resolution computed tomographyHeliumPulmonary function testingIsotopesmedicineHumansEffective diffusion coefficientRadiology Nuclear Medicine and imagingFunctional evaluationmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingGeneral MedicineMiddle Agedrespiratory systemSingle Lung TransplantationMagnetic Resonance ImagingRespiratory Function Testsrespiratory tract diseasesLung densityPulmonary EmphysemaConcomitantFemaleRadiologyTomography X-Ray ComputedbusinessNuclear medicineLung TransplantationInvestigative Radiology
researchProduct

Kardio-MRT

2004

Since initial reports in the early 1990s cardiac magnetic resonance imaging (CMR) has matured and is likely to become an established method for routine cardiac diagnostics. The development of faster gradient-echo sequences and stronger magnetic fields has led to improved temporal and spatial resolution. Myocardial viability can be examined by morphological and functional analysis. Contrast enhanced MRI (ceMRI), perfusion measurements and regional wall motion analysis are the major diagnostic tools. The ability to image in arbitrary double oblique planes provides comprehensive visualization of the heart. The introduction of the MR navigator technique allowed for free-breathing motion correct…

medicine.medical_specialtyMotion compensationCONTRAST ENHANCED MRImedicine.diagnostic_testbusiness.industrySteady-state free precession imagingmedicine.diseaseCoronary arteriesmedicine.anatomical_structureRestenosisCardiac magnetic resonance imagingmedicineRadiologyCardiology and Cardiovascular MedicinebusinessCollateralizationPerfusionZeitschrift f�r Kardiologie
researchProduct

Quantification of myocardial blood flow and blood flow reserve in the presence of arterial dispersion: A simulation study

2002

Myocardial blood flow (MBF) can be quantified using dynamic T1-weighted MRI of diffusible tracers and a mathematical model of underlying vasculature. Quantification of MBF by means of T1- weighted MRI requires knowledge of the arterial input function (AIF). The AIF can be estimated from the left ventricular (LV) cavity. However, dispersion may occur between the LV and the tissue of interest because of the laminar blood flow profiles, branching of venules, and because of stenosis. To evaluate the influence of dispersion on the results of MBF quantification, a simulation study was performed. The dispersion was described as a convolution of the AIF with an exponential residue function. Synthet…

medicine.medical_specialtyHemodynamicsCoronary DiseaseVentricular Function LeftCoronary CirculationInternal medicinemedicineHumansComputer SimulationRadiology Nuclear Medicine and imagingArterial input functionChemistrybusiness.industryHeartLaminar flowBlood flowPerfusion reservemedicine.diseaseMagnetic Resonance ImagingStenosismedicine.anatomical_structureCardiologyNuclear medicinebusinessPerfusioncirculatory and respiratory physiologyArteryMagnetic Resonance in Medicine
researchProduct

3He-MRI-based measurements of intrapulmonarypO2 and its time course during apnea in healthy volunteers: first results, reproducibility, and technical…

2000

We applied a recently developed method of following the time course of the intrapulmonary oxygen partial pressure p(O2)(t) during apnea by (3)He MRI to healthy volunteers. Using two imaging series with different interscan times during two breathholds (double acquisition technique), relaxation of (3)He due to paramagnetic oxygen and depolarization by RF pulses were discriminated. In all four subjects, the temporal evolution of p(O2) was found to be linear, and was described by an initial partial pressure p(0) and a decrease rate R. Also, regional differences of both p(0) and R were observed. A correlation between p(0) and R was apparent. Finally, we discuss limitations of the double acquisit…

Reproducibilitymedicine.diagnostic_testChemistryApneaMagnetic resonance imagingNuclear magnetic resonanceTime courseHealthy volunteersmedicineMolecular MedicineRadiology Nuclear Medicine and imagingmedicine.symptomSpectroscopyRegional differencesLung functionAcquisition techniqueNMR in Biomedicine
researchProduct

Quantitative myocardial perfusion imaging using different autocalibrated parallel acquisition techniques

2008

Purpose To compare three different autocalibrated parallel acquisition techniques (PAT) for quantitative and semiquantitative myocardial perfusion imaging. Materials and Methods Seven healthy volunteers underwent myocardial first-pass perfusion imaging at rest using an SR-TrueFISP pulse sequence without PAT and while using GRAPPA, mSENSE, and TSENSE. signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), normalized upslopes (NUS), and myocardial blood flow (MBF) were calculated. Artifacts, image noise, and overall image quality were qualitatively assessed. Furthermore, the relation between signal intensity (SI) and contrast medium (CM) concentration was determined in phantoms. Results …

AdultMalemedicine.diagnostic_testPhantoms Imagingbusiness.industryImage qualityPerfusion scanningPulse sequenceBlood flowMagnetic Resonance ImagingMyocardial perfusion imagingContrast mediumCoronary CirculationHealthy volunteerscardiovascular systemmedicineImage noiseHumansFemaleRadiology Nuclear Medicine and imagingNuclear medicinebusinessMathematicsJournal of Magnetic Resonance Imaging
researchProduct

Intrapulmonary 3He Gas Distribution Depending on Bolus Size and Temporal Bolus Placement

2008

OBJECTIVE: Dynamic ventilation (3)He-MRI is a new method to assess pulmonary gas inflow. As differing airway diameters throughout the ventilatory cycle can influence gas inflow this study intends to investigate the influence of volume and timing of a He gas bolus with respect to the beginning of the tidal volume on inspiratory gas distribution. MATERIALS AND METHODS: An ultrafast 2-dimensional spoiled gradient echo sequence (temporal resolution 100 milliseconds) was used for dynamic ventilation (3)He-MRI of 11 anesthetized and mechanically ventilated pigs. The applied (3)He gas bolus was varied in volume between 100 and 200 mL. A 150-mL bolus was varied in its application time after the beg…

Signal delayMaterials sciencePulmonary Gas ExchangeSwineVolume variationGeneral MedicineInflowHeliumMagnetic Resonance ImagingBolus (medicine)IsotopesRise timeAnesthesiaTemporal resolutionAdministration InhalationAnimalsRadiology Nuclear Medicine and imagingPulmonary VentilationLungSoftwareTidal volumeGradient echoBiomedical engineeringInvestigative Radiology
researchProduct

Reformatierungen als Lösungsansatz für die Problematik der unterschiedlichen Schichtführung beim Vergleich von3He-MRT und HR-CT der Lunge

2003

Purpose: 3 He-MRI of the lung has been shown to be a sensitive method for functional imaging of the lung. A previous study compared 3 He-MRI (coronal planes) with CT (transverse planes) by looking for ventilation defects and their pathomorphologic correlation. Anatomic structures, such as lobar fissures and hilar vessels, were used for orientation, but the reliable assignment of ventilation defects to lung segments is problematic. The present work compares multiplanar reformations of 3 He-MRI and HR-CT, which were generated from planes determined by the respective method, and investigates their suitability as a solution of this problem. Materials and Methods: A total of 16 data sets taken f…

ThoraxLungbusiness.industrymedicine.medical_treatmentrespiratory systemTransverse planemedicine.anatomical_structureCoronal planemedicineBreathingLung transplantationRadiology Nuclear Medicine and imagingLung emphysemaTomographyNuclear medicinebusinessRöFo - Fortschritte auf dem Gebiet der R
researchProduct

Analysis of discrete and continuous distributions of ventilatory time constants from dynamic computed tomography.

2005

In this study, an algorithm was developed to measure the distribution of pulmonary time constants (TCs) from dynamic computed tomography (CT) data sets during a sudden airway pressure step up. Simulations with synthetic data were performed to test the methodology as well as the influence of experimental noise. Furthermore the algorithm was applied to in vivo data. In five pigs sudden changes in airway pressure were imposed during dynamic CT acquisition in healthy lungs and in a saline lavage ARDS model. The fractional gas content in the imaged slice (FGC) was calculated by density measurements for each CT image. Temporal variations of the FGC were analysed assuming a model with a continuous…

SwineInformation Storage and RetrievalComputed tomographyModels BiologicalSensitivity and SpecificitySynthetic dataImaging Three-DimensionalImage Interpretation Computer-AssistedmedicineAnimalsRadiology Nuclear Medicine and imagingComputer SimulationLungSimulationMathematicsRadiological and Ultrasound Technologymedicine.diagnostic_testfungiMathematical analysisTime constantReproducibility of ResultsImage EnhancementNoiseKineticsDistribution (mathematics)Continuous distributionsBreathingVentilatory timePulmonary VentilationTomography X-Ray ComputedAlgorithmsPhysics in medicine and biology
researchProduct

MRI of tarantulas: morphological and perfusion imaging.

2005

This paper describes a study performed to evaluate the feasibility of using a 1.5-T whole-body magnetic resonance imaging (MRI) equipment, in combination with pharmacokinetic modeling, to obtain in vivo information about the morphology and perfusion of tarantulas (Eurypelma californicum). MRI was performed on three tarantulas using spin-echo sequences for morphological imaging and a rapid spoiled gradient-echo sequence for dynamic imaging during and after contrast medium (CM; Gd-DTPA) injection. Signal enhancement in dynamic measurements was evaluated with a pharmacokinetic two-compartment model. Spin-echo images showed morphological structures well. Dynamic images were of sufficient qualit…

TarantulaGadolinium DTPAScannermedicine.diagnostic_testbiologybusiness.industryDynamic imagingBiomedical EngineeringBiophysicsContrast MediaMagnetic resonance imagingPerfusion scanningbiology.organism_classificationMagnetic Resonance ImagingContrast mediumNuclear magnetic resonanceDynamic contrast-enhanced MRIArachnidamedicineAnimalsRadiology Nuclear Medicine and imagingbusinessPerfusionMagnetic resonance imaging
researchProduct

Kernspintomographie der Lunge mit hochpolarisiertem Helium-3

1999

Mit kernspinpolarisiertem 3He-Gas ist es moglich, das bildgebende Verfahren der Kernspintomographie auf Hohlraume auszuweiten. Fur die Lungendiagnostik eroffnen sich damit vollig neue Moglichkeiten.

Physik Journal
researchProduct

Flip angle considerations in (3)helium-MRI.

2000

3Helium-MRI ((3)He-MRI) can be used for analysis of lung function, e. g. dynamic imaging of ventilation and gas diffusion within the lung, assessment of intrapulmonary oxygen concentrations and their time course. During imaging, the irreversible signal loss due to depolarizing radio frequency excitations can be described using the flip angle (FA) alpha. This parameter has to be quantified in order to account for it during quantitative assessment of the (3)helium signal intensity and its temporal development. This technical report reviews two different methods to determine alpha. Limitations and possible error sources of each method are discussed.

Signal processingMaterials sciencemedicine.diagnostic_testEstimation theoryDynamic imagingMagnetic resonance imagingSignalHeliumMagnetic Resonance ImagingRespiratory Function TestsOxygenNuclear magnetic resonanceFlip angleIsotopesmedicineTidal VolumeMolecular MedicineHumansRadiology Nuclear Medicine and imagingComputer SimulationRadio frequencyHyperpolarization (physics)SpectroscopyNMR in biomedicine
researchProduct

Prospektive Machbarkeitsstudie zum Vergleich von Röntgenübersichtsaufnahme und Thorax-MRT in Atemanhaltetechnik am offenen Niederfeldgerät

2002

PURPOSE MR investigations using a breath-hold sequence at an open low-field MR had to be compared to chest X-rays in patients with a wide spectrum of cardio-thoracic pathologies. MATERIAL AND METHODS 114 patients and three volunteers who actually received a chest X-ray due to different indications underwent triplanar breath-hold (17 - 20 s) True-FISP sequence using a 0.2 T low-field MR (Siemens Magnetom Open, TR/TE/alpha: 7.3/3.5/80 degrees, SD: 10 mm, Pixel: 2.81 x 1.41 mm) a mean of 5.1 (+/- 8.2) days later. RESULTS Signal-to-noise ratio as basics for pattern recognition was 3.2 in nodule, 5.0 in infiltration, and 12.0 in effusion, and therefore True-FISP is usable for the detection of th…

Thoraxmedicine.medical_specialtyLungPleural effusionbusiness.industryRespiratory diseaseNodule (medicine)medicine.diseasePleural diseasemedicine.anatomical_structureEffusionmedicinePericardiumRadiology Nuclear Medicine and imagingRadiologymedicine.symptombusinessRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Volumetry of Ventilated Airspaces by 3He MRI

2001

To develop a validated post-processing routine for volumetry of the ventilated airspaces by 3He MRI.3Helium MRI and pulmonary function tests were performed in seven healthy volunteers. After segmentation of ventilated airspaces, their volumes were calculated. Functional residual capacity (FRC) was used as a reference. For comparison of absolute volumes, correction factors were evaluated.Mean lung volume (+/- standard deviation) calculated from 3He MRI was 4,082 +/- 908 mL and mean FRC was 3,696 +/- 1166 mL, with a mean difference of 386 mL (r = 0.88). After correction for the relative pulmonary air content (factor 0.82), posture (0.72), and the individual tidal volume, 3He MRI volume was 3,…

AdultMaleIsotopesImage Processing Computer-AssistedHumansFemaleRadiology Nuclear Medicine and imagingGeneral MedicineLung Volume MeasurementsHeliumMagnetic Resonance ImagingInvestigative Radiology
researchProduct

Assessment of tumor microcirculation with dynamic contrast-enhanced MRI in patients with esophageal cancer: initial experience.

2008

PURPOSE: To investigate the feasibility and impact of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) on tumor characterization and response to radiochemotherapy (RCT) in patients with esophageal cancer. MATERIALS AND METHODS: A total of 48 patients underwent DCE-MRI to assess tumor microcirculation based on a two-compartment model function. Effects of RCT on kinetic parameters were studied in 12 patients with squamous cell carcinoma. RESULTS: Tumor microcirculation differs with respect to histological subtype: squamous cell carcinomas showed lower values of amplitude A (leakage space, P = 0.015) and higher contrast agent exchange rates (k(21), P = 0.225) compared with adenoc…

AdultGadolinium DTPAMalemedicine.medical_specialtyEsophageal NeoplasmsUrologyContrast MediaAdenocarcinomaMicrocirculationlaw.inventionRandomized controlled triallawmedicineCarcinomaImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingAgedObserver Variationmedicine.diagnostic_testbusiness.industryMicrocirculationTherapeutic effectMagnetic resonance imagingEsophageal cancerMiddle Agedmedicine.diseaseImage EnhancementMagnetic Resonance ImagingTreatment OutcomeDynamic contrast-enhanced MRICarcinoma Squamous CellFeasibility StudiesHistopathologyFemaleRadiologybusinessJournal of magnetic resonance imaging : JMRI
researchProduct

Lack of mutagenic and co-mutagenic effects of magnetic fields during magnetic resonance imaging

2001

Mutagenic and co-mutagenic effects of static, pulsed bipolar gradient, and high-frequency magnetic fields, as well as combinations of them, were examined using the Ames test. The Ames test using Salmonella typhimurium bacteria, wild-type strain RTA, preincubation assay, without metabolic activation, was performed. All combinations of magnetic fields were tested with and without co-exposure to N-methyl-N′-nitro-N-nitrosoguanidine and benzo[a]pyrene-4,5-oxide, ethylene oxide, carboplatin, or cisplatin. As expected, chemical mutagens caused a clear-cut increase of the revertants in the Ames test. However, neither the static fields nor a combination of a static magnetic field with the time-vary…

Salmonella typhimuriumChemical mutagensmedicine.diagnostic_testStrain (chemistry)Mutagenicity TestsChemistryfungifood and beveragesMagnetic resonance imagingEnvironmental Exposureequipment and suppliesMagnetostaticsMagnetic Resonance ImagingMagnetic fieldAmes testElectromagnetic FieldsNuclear magnetic resonanceMutagenesismedicineAnimalsRadiology Nuclear Medicine and imaginghuman activitiesJournal of Magnetic Resonance Imaging
researchProduct

Bestimmung der myokardialen Perfusionsreserve bei KHK-Patienten mit der kontrastmittelverstärkten MRT: Ein Vergleich zwischen semiquantitativer und q…

2002

OBJECTIVE Comparison between two semiquantitative methods and a quantitative evaluation of myocardial blood flow (MBF) for assessment of myocardial perfusion reserve (MPR) in patients with CAD. MATERIAL AND METHODS 9 patients with coronary stenoses > 50 % were examined with an ECG-gated Saturation Recovery Turbo FLASH sequence by using Gd-DTPA as contrast agent (CA). The entive measurements were performed both during rest and hyperemia induced by adenosine. The up-slopes of the signal-time S(t) curves in the myocardium and left ventricular (LV) cavity were evaluated by a linear fit. MPR was calculated from the original up-slopes of the myocardial S(t) curves and from the up-slopes, which we…

medicine.diagnostic_testbusiness.industryIschemic myocardiumIschemiaSaturation recoveryMagnetic resonance imagingBlood flowPerfusion reservemedicine.diseaseMedicineRadiology Nuclear Medicine and imagingIn patientbusinessNuclear medicinePerfusionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

No influence of magnetic fields on cell cycle progression using conditions relevant for patients during MRI.

2003

The purpose of this study was to examine whether exposure to magnetic fields (MFs) relevant for magnetic resonance imaging (MRI) in clinical routine influences cell cycle progression in two tumor cell lines in vitro. HL60 and EA2 cells were exposed to four types of MFs: (i) static MF of 1.5 and 7.05 T, (ii) extremely low frequency magnetic gradient fields (ELFMGFs) with ± 10 mT/m and 100 Hz, as well as ± 100 mT/m and 100 Hz, (iii) pulsed high frequency MF in the radiofrequency (RF) range (63.6 MHz, 5.8 μT), and (iv) a combination of (i–iii). Exposure periods ranged from 1 to 24 h. Cell cycle distribution (G0/G1, S, and G2/M phases) was analyzed by flow cytometry. Cell cycle analysis did not…

medicine.diagnostic_testPhysiologyChemistryCell CycleBiophysicsMagnetic resonance imagingDose-Response Relationship RadiationHL-60 CellsGeneral MedicineEnvironmental ExposureCell cycleMagnetostaticsRadiation DosageMagnetic Resonance ImagingFlow cytometryNuclear magnetic resonanceElectromagnetic FieldsCell culturemedicineHumansRadiology Nuclear Medicine and imagingExtremely low frequencyIrradiationRadiometryBioelectromagneticsBioelectromagnetics
researchProduct

Neue Entwicklungen in der MRT des Thorax

2001

Wegen technischer und physikalischer Einschrankungen wurde die MRT bisher nur selten zur Darstellung der Lunge eingesetzt. Neue Entwicklungen haben allerdings die Moglichkeiten der anatomischen Darstellung mittels MRT erheblich verbessert und gleichzeitig neue Perspektiven fur funktionelle Darstellungen eroffnet. Dazu gehoren Techniken zur funktionellen Untersuchung der Perfusion (Kontrastmittel, MR-Angiographie) und der Ventilation der Lunge (inhalierte aerosolierte Kontrastmittel, Sauerstoff, hochpolarisierte Edelgase [He-3, Xe-129] und fluorinierte Gase [SF6]). Die Gleichmasigkeit der Ventilation, Bestimmung von Lungenvolumina, Grose der Luftraume, intrapulmonale Sauerstoffkonzentration,…

Gynecologymedicine.medical_specialtyLung diseasebusiness.industrymedicineRadiology Nuclear Medicine and imagingbusinessDer Radiologe
researchProduct

Comparison of three accelerated pulse sequences for semiquantitative myocardial perfusion imaging using sensitivity encoding incorporating temporal f…

2007

Purpose To investigate the parallel acquisition technique sensitivity encoding incorporating temporal filtering (TSENSE) with three saturation-recovery (SR) prepared pulse sequences (SR turbo fast low-angle shot [SR-TurboFLASH], SR true fast imaging with steady precession [SR-TrueFISP], and SR-prepared segmented echo-planar-imaging [SR-segEPI]) for semiquantitative first-pass myocardial perfusion imaging. Materials and Methods In blood- and tissue-equivalent phantoms the relationship between signal intensity (SI) and contrast-medium concentration was evaluated for the three pulse sequences. In volunteers, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and normalized upslopes (N…

AdultMaleImage qualityContrast MediaImage processingSensitivity and SpecificityMyocardial perfusion imagingHeart RateImage Processing Computer-AssistedImage noiseHumansMedicineRadiology Nuclear Medicine and imagingmedicine.diagnostic_testEcho-Planar ImagingPhantoms ImagingPulse (signal processing)business.industryMyocardiumReproducibility of ResultsLinearityMagnetic resonance imagingMagnetic Resonance ImagingPerfusionLinear rangeFemalebusinessNuclear medicineBiomedical engineeringJournal of Magnetic Resonance Imaging
researchProduct

Eine Kombination niedrig und hochauflösender dynamischer T1-gewichteter Sequenzen zur besseren Beurteilung der Morphologie Kontrastmittel aufnehmende…

2002

Purpose: Presentation of a new protocol for simultaneous acquisition of both low and high resolution T 1 -weighted images of breast lesions for dynamic contrast-enhanced MR mammography. Demonstration of possible diagnostic improvement with representative measurements in patients with suspected breast cancer by adding morphologic parameters from high resolution sequences to the analysis of the signal-time curve. Materials and Methods: Dynamic MR imaging was performed with a 1.5 T system (Magnetom SONATA, Siemens Medical Systems, Germany) and the manufacturer's double-breast coil. Coronal T 1 -weighted 3D FLASH sequences (spatial resolution 1.25 ×1.25 mm 2 ; slice thickness 1.7 mm) were acqui…

Contrast mediumNuclear magnetic resonanceMaterials sciencePulse (signal processing)Dynamic contrast-enhanced MRIResolution (electron density)Radiology Nuclear Medicine and imagingSensitivity (control systems)Image resolutionSignalImaging phantomBiomedical engineeringRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Selbstorganisierende neuronale Netze zur automatischen Detektion und Klassifikation von Kontrast(mittel)-verstärkten Läsionen in der dynamischen MR-M…

2005

Purpose: Investigation and statistical evaluation of "Self-Organizing Maps," a special type of neural networks in the field of artificial intelligence, classifying contrast enhancing lesions in dynamic MR-mammography. Material and Methods: 176 investigations with proven histology after core biopsy or operation were randomly divided into two groups. Several Self-Organizing Maps were trained by investigations of the first group to detect and classify contrast enhancing lesions in dynamic MR-mammography. Each single pixel's signal/time curve of all patients within the second group was analyzed by the Self-Organizing Maps. The likelihood of malignancy was visualized by color overlays on the MR-…

Pathologymedicine.medical_specialtyContrast enhancementbusiness.industrymedia_common.quotation_subjectSecond opinionmedicine.diseaseMalignancyFibroadenomaSingle pixelmedicineContrast (vision)Radiology Nuclear Medicine and imagingTime curvebusinessCore biopsyNuclear medicinemedia_commonRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Measurements of alveolar pO2 using 19F-MRI in partial liquid ventilation.

2003

Rationale and Objectives: Partial liquid ventilation using Perfluorcarbon (PFC) is an innovative treatment of acute respiratory distress syndrome. However, the underlying mechanisms are not totally clear. The aim was to investigate the distribution of oxygen partial pressure within the PFC-filled lung (ppO 2 ). Methods: Nine pigs underwent partial liquid ventilation, receiving 20 mL PFC/kg bodyweight (bw). Measurements were obtained by a chemical shift selective TurboFLASH sequence at different axial lung levels. ppO 2 was calculated from 1 9 F-MRI by nonlinear curve T 1 -fitting technique after noise correction. Results: Quantification and distribution of ppO 2 was performed successfully. …

Respiratory Distress SyndromeLungLiquid VentilationChemistryPartial PressureDependent lungGeneral MedicinePartial pressureMagnetic Resonance ImagingLimited accessOxygenPulmonary Alveolimedicine.anatomical_structureFluorocarbon PolymersIn vivoAnesthesiamedicineDistribution (pharmacology)AnimalsRadiology Nuclear Medicine and imagingPartial liquid ventilationPulmonary VentilationPerfusionBiomedical engineeringInvestigative radiology
researchProduct

Comparison of magnetic resonance imaging of inhaled SF6 with respiratory gas analysis

2008

Magnetic resonance imaging of inhaled fluorinated inert gases ((19)F-MRI) such as sulfur hexafluoride (SF(6)) allows for analysis of ventilated air spaces. In this study, the possibility of using this technique to image lung function was assessed. For this, (19)F-MRI of inhaled SF(6) was compared with respiratory gas analysis, which is a global but reliable measure of alveolar gas fraction. Five anesthetized pigs underwent multiple-breath wash-in procedures with a gas mixture of 70% SF(6) and 30% oxygen. Two-dimensional (19)F-MRI and end-expiratory gas fraction analysis were performed after 4 to 24 inhaled breaths. Signal intensity of (19)F-MRI and end-expiratory SF(6) fraction were evaluat…

SpirometryCorrelation coefficientSwineSulfur HexafluorideBiomedical EngineeringBiophysicsAnalytical chemistrychemistry.chemical_elementFraction (chemistry)Sensitivity and SpecificityOxygenchemistry.chemical_compoundNuclear magnetic resonanceAdministration InhalationmedicineAnimalsRadiology Nuclear Medicine and imagingRespiratory systemLungReproducibilitymedicine.diagnostic_testPulmonary Gas ExchangeReproducibility of ResultsMagnetic resonance imagingImage EnhancementMagnetic Resonance ImagingSulfur hexafluorideBreath TestschemistrySpirometryMagnetic Resonance Imaging
researchProduct

Visualization of alveolar recruitment in a porcine model of unilateral lung lavage using3He-MRI

2009

BACKGROUND: In the acute respiratory distress syndrome potentially recruitable lung volume is currently discussed. (3)He-magnetic resonance imaging ((3)He-MRI) offers the possibility to visualize alveolar recruitment directly. METHODS: With the approval of the state animal care committee, unilateral lung damage was induced in seven anesthetized pigs by saline lavage of the right lungs. The left lung served as an intraindividual control (healthy lung). Unilateral lung damage was confirmed by conventional proton MRI and spiral-CT scanning. The total aerated lung volume was determined both at a positive end-expiratory pressure (PEEP) of 0 and 10 mbar from three-dimensionally reconstructed (3)H…

Pathologymedicine.medical_specialtySwinemedicine.medical_treatmentAcute Lung InjuryHemodynamicsAtelectasisAcute respiratory distressBronchoalveolar LavageHeliumPositive-Pressure RespirationAnimal modelIsotopesAnimalsMedicineLung volumesLungSalineLungPulmonary Gas Exchangebusiness.industryHemodynamicsGeneral Medicinerespiratory systemmedicine.diseaseMagnetic Resonance ImagingRespiratory Function Testsrespiratory tract diseasesDisease Models AnimalTreatment OutcomeAnesthesiology and Pain Medicinemedicine.anatomical_structureModels AnimalbusinessNuclear medicineLung lavageActa Anaesthesiologica Scandinavica
researchProduct

Quantification of resting myocardial blood flow in a pig model of acute ischemia based on first-pass MRI

2005

Qualitative and semiquantitative contrast-enhanced (CE) dynamic perfusion MRI techniques are established as noninvasive diagnostic means of assessing coronary artery disease. However, to date quantification of myocardial blood flow (MBF) has not reached the same acceptance as MBF quantification with nuclear techniques. To validate quantification of MBF at rest using the extracellular contrast agent (CA) Gd-DTPA, we performed an animal study in a pig model of acute myocardial ischemia. We quantified MBF from MRI data with a mathematical model (MMID4) of the underlying vasculature. These MBF results were subsequently compared with the results from fluorescent microspheres. The study showed a …

Gadolinium DTPAmedicine.medical_specialtyMyocardial ischemiaSwineMyocardial IschemiaContrast MediaStatistics NonparametricAcute ischemiaCoronary artery diseaseFluorescent microspheresCoronary CirculationInternal medicinemedicineAnimalsRadiology Nuclear Medicine and imagingFirst passbusiness.industryPig modelBlood flowmedicine.diseaseMagnetic Resonance ImagingDisease Models AnimalAcute DiseaseCardiologybusinessPerfusioncirculatory and respiratory physiologyMagnetic Resonance in Medicine
researchProduct

Ultraschnelle MRT der Lungenventilation mittels hochpolarisiertem Helium-3*

2000

Objective Assessment of the temporal and spatial dynamics of hyperpolarized Helium-3 (3He) distribution in the lung with ultrafast gradient-echo magnetic-resonance imaging. Material and methods Coronal images of the lung were acquired using ultrafast gradient-echo pulse sequences with TR/TE = 3.3 ms/1.3 ms (slice thickness, 40 mm) and TR/TE = 2.0 ms/0.7 ms (without slice selection). A series of 80 or 160 projection images was obtained with 210 ms or 130 ms temporal resolution, respectively. Imaging was performed during several respiratory cycles after application of a single bolus of 300 mL hyperpolarized 3He. Measurements were performed in six healthy volunteers (spontaneous breathing). Re…

Lungmedicine.anatomical_structureNuclear magnetic resonanceMaterials sciencePulse (signal processing)Temporal resolutionBreathingmedicineWashoutRadiology Nuclear Medicine and imagingHyperpolarized Helium 3Image resolutionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Subsecond fluorine-19 MRI of the lung

2006

Minimal scan times in rapid fluorine-19 MRI using sulfur hexafluoride (SF6) have been on the order of 10 s. Because of the very short T1 relaxation time of SF6 (T1 = 1.65 ms), high receiver bandwidths are necessary to allow for a high number of excitations. Since high bandwidths cause high levels of electronic noise, SNR per acquisition has been too low to further reduce scan time. The purpose of this study was to investigate whether scan times could be reduced using hexafluoroethane (C2F6), a gas with a longer T1 (T1 = 7.9 ms) at a relatively low bandwidth of 488 Hz/pixel. Gradient-echo images were acquired during and after completion of the wash-in of a 70% C2F6- 30% O2 mixture. Peak SNR …

PixelSwineRapid imagingSpin–lattice relaxationContrast Mediachemistry.chemical_elementFluorineImage EnhancementMagnetic Resonance ImagingSulfur hexafluorideScan timechemistry.chemical_compoundImaging Three-DimensionalNuclear magnetic resonanceIsotopeschemistryHexafluoroethaneFluorineAnimalsRadiology Nuclear Medicine and imagingGasesLungLung ventilationMagnetic Resonance in Medicine
researchProduct

Ein Auswerteprogramm zur quantitativen Analyse von Messungen des alveolären Sauerstoffpartialdrucks (pAO2) mit der sauerstoffsensitiven 3He-MR-Tomogr…

2004

Purpose: To develop a software tool for quantitative analysis of alveolar oxygen partial pressure (p A O 2 ) as well as its time course during apnea. Material and Methods: T 1 -relaxation times of hyperpolarized 3 He are reduced by paramagnetic oxygen rendering 3 He-MRI sensitive to oxygen and thus allowing the assessment of the local oxygen partial pressure in the pulmonary airspaces. Oxygen-related relaxation and loss of polarization by RF-excitation can be discriminated by acquiring two image series with varying interscan delay and/or flip angles. Software was developed to calculate the p A O 2 and the decay rate in user-defined regions of interest (ROIs) automatically. Moreover, paramet…

LungMaterials sciencemedicine.diagnostic_testbusiness.industrychemistry.chemical_elementMagnetic resonance imagingPartial pressuremedicine.diseaseVentilation/perfusion ratioOxygenPulmonary embolismSoftwareNuclear magnetic resonancemedicine.anatomical_structurechemistrymedicineRadiology Nuclear Medicine and imagingRespiratory systembusiness
researchProduct

Structural and Functional Characterization of Chronic Obstructive Lung Disease and Emphysema Using 3He- MRI: Comparison with CT and Pulmonary Functio…

2005

mor types. For these reasons, Matrigel impregnated with angiogenic hormone, basic-Fibroblast Growth Factor (bFGF), in a mouse model has been extensively used in fundamental angiogenesis research to induce endothelial cell differentiation and successfully allow the study of different phases of the angiogenesis process. The objective of this study was to evaluate the ability of functional ultrasound imaging (fUSI) to provide data allowing the quantification of the angiogenic process, using the Matrigel model.

MatrigelPathologymedicine.medical_specialtyAngiogenic ProcessAngiogenesisbusiness.industryGrowth factormedicine.medical_treatmentmedicine.diseaseEndothelial cell differentiationObstructive lung diseasePulmonary function testingUltrasound imagingmedicineRadiology Nuclear Medicine and imagingbusinessAcademic Radiology
researchProduct

Funktionelle Bildgebung der Lunge mit gasförmigem Kontrastmittel: ³Helium-Magnetresonanztomographie

2005

Current imaging methods of the lung concentrate on morphology as well as on the depiction of the pulmonary parenchyma. The need of an advanced and more subtle imaging technology compared to conventional radiography is met by computed topography as the method of choice. Nevertheless, computed tomography yields very limited functional information. This is to be derived from arterial blood gas analysis, spirometry and body plethysmography. These methods, however, lack the scope for regional allocation of any pathology. Magnetic resonance imaging of the lung has been advanced by the use of hyperpolarised (3)Helium as an inhaled gaseous contrast agent. The inhalation of the gas provides function…

Spirometrymedicine.medical_specialtyMaterials sciencemedicine.diagnostic_testRelaxation (NMR)Magnetic resonance imagingFunctional imagingNuclear magnetic resonanceTemporal resolutionmedicineImaging technologyRadiology Nuclear Medicine and imagingRadiologyPreclinical imagingDiffusion MRIRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Systematische Analyse der Geometrie eines definierten Kontrastmittelbolus - Implikationen für die kontrastmittelverstärkte 3D-MR-Angiographie thoraka…

2005

Purpose: Little is known about the dispersion of a defined contrast bolus during its passage through the heart and pulmonary vasculature. The purpose of this study was to analyze factors influencing a defined contrast bolus for ce-MRA of thoracic vessels. Materials and Methods: For analysis of bolus geometry, an ECG-gated saturation-recovery Turbo-Flash sequence with a TI of 20 msec was used. It was acquired axially at the level of the pulmonary trunc, so that with one data acquisition a curve analysis was possible in the ascending and descending aorta, and in the pulmonary trunc. Twenty-nine patients received 3 ml of Gd-DTPA diluted with saline to a total of 20 ml. Contrast injection was d…

Cardiac function curvemedicine.diagnostic_testbusiness.industryThoracic cavityGeometrySaline flushMagnetic resonance angiographyContrast mediumBolus (medicine)medicine.anatomical_structureDescending aortamedicine.arteryAscending aortaMedicineRadiology Nuclear Medicine and imagingbusinessRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Kryotherapie maligner Tumoren: Untersuchungen mittels MRT im Tierexperiment und Vergleich mit morphologischen Veränderungen*

2001

son with pathological changes in mice. Purpose: Aim of our study was to investigate the efficacy of 7 F cryoprobes for percutaneous use morpho- and histologically, to examine the role of apoptosis after cryotherapy, and to compare contrast-enhanced MRI with histopathological findings at different time intervals in a tumor-mouse model. Methods: Percutaneous cryotherapy was performed in 15 immunocompromised nude mice with subcutaneously implanted tumors using the non-small-cell lung cancer cell line Lu 1. In group a) 7 mice were sacrificed after definite time intervals and histological examinations were done for evaluation of necrosis and apoptosis (HE; TUNEL assay); 2 mice are in long-term f…

medicine.medical_specialtyPathologyNecrosisTUNEL assaymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentMagnetic resonance imagingHistologyCryotherapymedicine.diseasemedicineCarcinomaRadiology Nuclear Medicine and imagingHistopathologymedicine.symptombusinessPerfusionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Assessment of lung microstructure with magnetic resonance imaging of hyperpolarized Helium-3

2005

Magnetic resonance imaging of the apparent diffusion coefficient (ADC) of hyperpolarized Helium-3 is a new technique for probing pulmonary microstructure in vivo. The aim of this study was the assessment of potential sources of systematic errors of the ADC measurement. The influence of macroscopic motion was determined by measurements at two different delays after initiating the breath-hold, and before and after cardiac arrest. An intercentre comparison was performed in two age- and lung function-matched groups of lung-healthy volunteers at two research sites. Moreover, measurements of diffusion anisotropy were performed. We found no dependency of the ADC as a function of the delay after st…

Pulmonary and Respiratory MedicineTime FactorsSwinePhysiologyHyperpolarized Helium 3HeliumDiffusion AnisotropyNuclear magnetic resonanceIsotopesImage Processing Computer-AssistedmedicineAnimalsHumansEffective diffusion coefficientTissue DistributionDiffusion (business)LungLungmedicine.diagnostic_testChemistryGeneral NeuroscienceMagnetic resonance imagingMiddle AgedMicrostructureHeart ArrestDiffusion Magnetic Resonance Imagingmedicine.anatomical_structureBreath TestsCase-Control StudiesAnisotropyDiffusion MRIRespiratory Physiology & Neurobiology
researchProduct

k-Space filtering in 2D gradient-echo breath-hold hyperpolarized3He MRI: Spatial resolution and signal-to-noise ratio considerations

2002

In this work some of the factors that can influence the signal-to-noise ratio (SNR) and spatial resolution in MR images of inhaled hyperpolarized gases are systematically addressed. In particular, the effects of RF depletion of longitudinal polarization and image gradient diffusion dephasing were assessed in terms of their contribution to a k-space filter. By means of theoretical simulations and a novel method of experimental validation using a variable transverse magnetization of the 1H signal, systematic quantitative and qualitative investigations of the effects of k-space filtering intrinsic to imaging of hyperpolarized gas were made. A 2D gradient-echo image is considered for a range of…

Fourier Analysisbusiness.industryChemistryDephasingk-spaceFilter (signal processing)Polarization (waves)HeliumMagnetic Resonance Imaginglaw.inventionOpticsNuclear magnetic resonanceIsotopeslawImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingCartesian coordinate systemHyperpolarization (physics)businessImage resolutionImage gradientMagnetic Resonance in Medicine
researchProduct

3He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes

2000

MRI with hyperpolarized helium-3 (3He) provides high-resolution imaging of ventilated airspaces. The first aim of this 3He-study was to compare observations of localized signal defects in healthy smokers and non-smokers. A second aim was to describe relationships between parameters of lung function, volume of inspired 3He and signal-to-noise ratio. With Ethics Committee approval and informed consent, 12 healthy volunteers (seven smokers and five non-smokers) were studied. Imaging was performed in a 1.5 T scanner using a two-dimensional FLASH sequence at 30V transmitter amplitude (TR/TE/α = 11 ms/4.2 ms/<10°). Known amounts of 3He were inhaled from a microprocessor-controlled delivery device…

Lungbusiness.industryEthics committeeSmoking historyPulmonary function testingCorrelationmedicine.anatomical_structureHealthy volunteersBreathingmedicineMolecular MedicineRadiology Nuclear Medicine and imagingLung volumesNuclear medicinebusinessSpectroscopy
researchProduct

Functional MRI of the lung using hyperpolarized 3-helium gas

2004

Lung imaging has traditionally relied on x-ray methods, since proton MRI is limited to some extent by low proton density in the lung parenchyma and static field inhomogeneities in the chest. The relatively recent introduction of MRI of hyperpolarized noble gases has led to a rapidly evolving field of pulmonary MRI, revealing functional information of the lungs, which were hitherto unattainable. This review article briefly describes the physical background of the technology, and subsequently focuses on its clinical applications. Four different techniques that have been used in various human investigations are discussed: ventilation distribution, ventilation dynamics, and small airway evaluat…

Lung DiseasesMaterials scienceLungHelium gasbusiness.industryHyperpolarized Helium 3respiratory systemHeliumMagnetic Resonance ImagingOxygen uptakePulmonary function testingDiffusion imagingmedicine.anatomical_structureNuclear magnetic resonanceIsotopesAdministration InhalationBreathingmedicineHumansRadiology Nuclear Medicine and imagingProton densityNuclear medicinebusinessLungJournal of Magnetic Resonance Imaging
researchProduct

Analysis of intrapulmonary O2concentration by MR imaging of inhaled hyperpolarized helium-3

1999

Inhalation of hyperpolarized 3He allows magnetic resonance imaging (MRI) of ventilated airspaces.3He hyperpolarization decays more rapidly when interacting with paramagnetic O2. We describe a method for in vivo determination of intrapulmonary O2 concentrations ([O2]) based on MRI analysis of the fate of measured amounts of inhaled hyperpolarized3He in imaged regions of the lung. Anesthetized pigs underwent controlled normoventilation in a 1.5-T MRI unit. The inspired O2 fraction was varied to achieve different end-tidal [O2] fractions ([Formula: see text]). With the use of a specifically designed applicator,3He (100 ml, 35–45% polarized) was administered at a predefined time within single …

SwinePhysiologychemistry.chemical_elementHyperpolarized Helium 3HeliumOxygenIsotopesPhysiology (medical)Administration InhalationTidal VolumemedicineAnimalsHyperpolarization (physics)Respiratory systemLungTidal volumeLungmedicine.diagnostic_testInhalationbusiness.industryRespirationOsmolar ConcentrationMagnetic resonance imagingMagnetic Resonance ImagingOxygenmedicine.anatomical_structurechemistryFeasibility StudiesNuclear medicinebusinessJournal of Applied Physiology
researchProduct

FAIR and dynamic susceptibility contrast-enhanced perfusion imaging in healthy subjects and stroke patients.

2002

Purpose To compare dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI) and the flow-sensitive alternating inversion recovery (FAIR) technique for measuring brain perfusion. Materials and Methods We investigated 12 patients with acute stroke, and 10 healthy volunteers with FAIR and DSC maps of regional cerebral blood volume (rCBV), mean transit time (MTT), and regional cerebral blood flow (rCBF). Results In volunteers good gray/white-matter contrast was observed in FAIR, rCBF, and rCBV maps. Regions with high signal intensities in FAIR matched well with high values of rCBV and rCBF. In ischemic stroke patients a high correlation (r = 0.78) of the ipsi- to contralate…

AdultMaleStroke patientContrast MediaPerfusion scanningmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingAgedmedicine.diagnostic_testbusiness.industryHealthy subjectsMagnetic resonance imagingMiddle AgedMagnetic Resonance ImagingStrokeCerebral blood volumeCerebral blood flowRegional Blood FlowCase-Control StudiesCerebrovascular CirculationAcute DiseaseFemaleNuclear medicinebusinessPerfusionDynamic susceptibilityJournal of magnetic resonance imaging : JMRI
researchProduct

Beurteilung der Durchgängigkeit von koronaren Bypassgefäßen mit einer 2D T2-gewichteten Turbo-Spin-Echo-Sequenz (HASTE) in Atemanhaltetechnik

1999

AIM To evaluate the patency of coronary artery bypass grafts with a 2D T2-weighted breath-hold turbo-spin-echo sequence. METHODS 38 patients with 97 grafts (19 internal mammary artery and 78 saphenous vein grafts) and a total of 120 distal anastomoses were studied at 1.5 Tesla in supine position using a phased array body coil. An ECG gated 2D T2-weighted breath-hold turbo-spin-echo sequence (HASTE) was performed. Reference method was selective coronary angiography. The image material was evaluated independently by two radiologists (observer one, a radiological fellow and the second a staff radiologist). RESULTS Observer 1 reached a sensitivity of 96% (72/75) and a specificity of 91% (20/22)…

medicine.medical_specialtySupine positionmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingAnastomosisMcNemar's testmedicine.anatomical_structurePositive predicative valueAngiographymedicineRadiology Nuclear Medicine and imagingRadiologyDerivationNuclear medicinebusinessArteryRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Dynamic contrast-enhanced myocardial perfusion imaging using saturation-prepared TrueFISP.

2002

Purpose To develop and test a saturation-recovery TrueFISP (SR-TrueFISP) pulse sequence for first-pass myocardial perfusion imaging. Materials and Methods First-pass magnetic resonance imaging (MRI) of Gd-DTPA (2 mL) kinetics in the heart was performed using an SR-TrueFISP pulse sequence (TR/TE/α = 2.6 msec/1.4 msec/55°) with saturation preparation TD = 30 msec before the TrueFISP readout. Measurements were also performed with a conventional saturation-recovery TurboFLASH (SRTF) pulse sequence for comparison. Results SR-TrueFISP images were of excellent quality and demonstrated contrast agent wash-in more clearly than SRTF images. The signal increase in myocardium was higher in SR-TrueFISP …

AdultGadolinium DTPAMaterials scienceImage qualityContrast MediaImage processingStatistics NonparametricMyocardial perfusion imagingNuclear magnetic resonancePrecontrastCoronary CirculationmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingImage resolutionmedicine.diagnostic_testbusiness.industryPhantoms ImagingMicrocirculationMagnetic resonance imagingPulse sequenceMagnetic Resonance ImagingNuclear medicinebusinessPerfusionJournal of magnetic resonance imaging : JMRI
researchProduct

MRI of Pulmonary Ventilation

2008

Gas imaging has opened the new field of direct imaging of pulmonary ventilation by MRI. The use of hyperpolarised 3He gas for MRI of the lung has been pioneered by a number of groups worldwide. Due to the enormous progress in the fields of hyperpolarisation technology, administration of hyperpolarised 3He, MR hardware, and MR pulse sequences significant progress has been made and the translation into the clinical arena has been accomplished. This chapter gives an overview of the technical methods for HP 3He MRI for human lung imaging, focusing on gas polarisation methods, background physics, MRI hardware considerations, MRI pulse sequence considerations, safety considerations for imaging in…

medicine.medical_specialtymedicine.anatomical_structurebusiness.industryMedicineLiquid ventilationMedical physicsDirect imagingbusinessHuman lung
researchProduct

Dynamic19F-MRI of pulmonary ventilation using sulfur hexafluoride (SF6) gas

2001

A new method for dynamic imaging of pulmonary wash-in and wash-out kinetics of inhaled sulfur hexafluoride (SF6) gas was developed. Measurements at the fluorine-19 Larmor frequency were performed in pigs using a gradient echo pulse sequence with 0.5 ms echo time and a measurement time of 9.1 s per image. Dynamic MRI was performed during wash-in and wash-out of SF6 gas in mechanically ventilated porcine lungs. A postprocessing strategy was developed for quantitative determination of wash-out time constants in the presence of noise. Mean wash-out constants were 4.78 ± 0.48 breaths vs. 4.33 ± 0.76 breaths for left and right lung when ventilation was performed with low tidal volume, and 1.73 ± …

Lungbusiness.industryDynamic imagingPulse sequenceQuantitative determinationSulfur hexafluoridechemistry.chemical_compoundmedicine.anatomical_structurechemistryDynamic contrast-enhanced MRIBreathingmedicineRadiology Nuclear Medicine and imagingNuclear medicinebusinessGradient echoBiomedical engineeringMagnetic Resonance in Medicine
researchProduct

MORT1/FADD is involved in liver regeneration

2006

AIM: To explore the role of the adaptor molecule in liver regeneration after partial hepatectomy (PH). METHODS: We used transgenic mice expressing an N-terminal truncated form of MORT1/FADD under the control of the albumin promoter. As previously shown, this transgenic protein abrogated CD95- and CD120a-mediated apoptosis in the liver. Cyclin A expression was detected using Western blotting. ELISA and RT-PCR were used to detect IL-6 and IL-6 mRNA, respectively. DNA synthesis in liver tissue was measured by BrdU staining. RESULTS: Resection of 70% of the liver was followed by a reduced early regenerative response in the transgenic group at 36 h. Accordingly, 36 h after hepatectomy, cyclin A …

Malemedicine.medical_specialtyFas-Associated Death Domain Proteinmedicine.medical_treatmentTransgeneCyclin AApoptosisMice TransgenicCyclin AMiceInternal medicinemedicineAnimalsHepatectomyFADDAdaptor Proteins Signal TransducingCell ProliferationbiologyInterleukin-6GastroenterologyGeneral MedicineFas receptorMolecular biologyPeptide FragmentsLiver regenerationLiver RegenerationBlotBasic ResearchEndocrinologyApoptosisbiology.proteinHepatectomyWorld Journal of Gastroenterology
researchProduct

19F-MRI of perflubron for measurement of oxygen partial pressure in porcine lungs during partial liquid ventilation

2001

A method for in vivo measurement of oxygen partial pressure (pO2) in porcine lungs during partial liquid ventilation (PLV) with perflubron (PFOB) was developed. A pulse sequence for high-resolution MRI of the distribution of PFOB in the lung after intratracheal administration was developed as well. Moreover, quantitative measurements of longitudinal relaxation time T(1) of (19)F resonances for assessment of regional pO2 are described. Due to the need to acquire data during a single expiratory breathhold, only low SNRs were achieved in vivo. Therefore, simulations were performed to investigate the influence of background noise on T(1) values calculated from data with low SNR. Based on these …

medicine.diagnostic_testChemistryPerflubronbusiness.industryMagnetic resonance imagingPartial pressureBackground noisechemistry.chemical_compoundIn vivomedicineRadiology Nuclear Medicine and imagingPartial liquid ventilationRespiratory systemNuclear medicinebusinessLongitudinal Relaxation TimeBiomedical engineeringMagnetic Resonance in Medicine
researchProduct

Functionalized Magnetic Nano-particles for Selective Targeting and Sensing of Cells

2008

Inorganic ChemistryChemistryNanoparticleNanotechnologyZeitschrift für anorganische und allgemeine Chemie
researchProduct

A multicenter measurement of magnetization transfer ratio in normal white matter

1999

To assess the importance of intercenter variations when measuring magnetization transfer ratio (MTR) in the brain, six European centers measured MTR in normal white matter. MTR ranged from 9 to 51 percent units (25 sequences). The effective flip angle of the saturating pulse divided by the pulse repetition time (ENRsat degrees/msec) was a good predictor of MTR (MTR = 3.25 ENRsat).

PhysicsDrug trialMagnetization Transfer MRIbusiness.industryWhite mattermedicine.anatomical_structureRepetition TimeFlip anglemedicineBrain mriRadiology Nuclear Medicine and imagingMagnetization transferNuclear medicinebusinessJournal of Magnetic Resonance Imaging
researchProduct

Diffusion-weighted MRI of the lung with hyperpolarized helium-3: A study of reproducibility

2005

Purpose To determine the reproducibility of several parameters of the ADC measurement by calculating the scan-to-scan intrasubject variability. Materials and Methods Measurements were performed using a gradient-echo sequence with a bipolar gradient for diffusion weighting (b = 3.89 sec/cm2). Five patients with pulmonary emphysema, and six healthy-lung volunteers were included in the study. Images were acquired after inspiration of 3He during a single inspiratory breath-hold. To assess the reproducibility, the measurement was performed twice (time between measurements = 20 minutes) without repositioning the subjects. Analysis was performed on the basis of region-of-interest (ROI) analysis an…

AdultMalePercentileHyperpolarized Helium 3HeliumStatistics NonparametricStandard deviationAdministration InhalationImage Processing Computer-AssistedHumansMedicineRadiology Nuclear Medicine and imagingAgedReproducibilityLungDiffusion weightingbusiness.industrySignificant differenceReproducibility of ResultsMiddle AgedDiffusion Magnetic Resonance Imagingmedicine.anatomical_structurePulmonary EmphysemaFemaleNuclear medicinebusinessDiffusion MRIJournal of Magnetic Resonance Imaging
researchProduct

Assessment of a single-acquisition imaging sequence for oxygen-sensitive (3)He-MRI.

2001

MRI of the lungs using hyperpolarized helium-3 (3He) allows the determination of intrapulmonary oxygen partial pressures (pO2). The need to separate competing processes of signal loss has hitherto required two different imaging series during two different breathing maneuvers. In this work, a new imaging strategy to measure pO2 by a single series of consecutive scans is presented. The feasibility of the method is demonstrated in three healthy human volunteers. Maps and histograms of intrapulmonary pO2 are calculated. Changes in the oxygen concentration of the inhaled gas mixture are well reproduced in the histograms. Monte Carlo (MC) simulations of the temporal evolution of 3He hyperpolariza…

ChemistryPartial PressureMonte Carlo methodHealthy subjectschemistry.chemical_elementrespiratory systemOxygenHeliumMagnetic Resonance ImagingOxygenNuclear magnetic resonanceIsotopesHistogramImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingLimiting oxygen concentrationComputer SimulationHyperpolarization (physics)Inhaled GasPulmonary VentilationLungMonte Carlo MethodLung functionMagnetic resonance in medicine
researchProduct

In-vitro-Untersuchung von biologischen und technischen Herzklappenprothesen im MRT: Beurteilung möglicher Anziehung und Erhitzung der Implantate

2000

PURPOSE In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves during MR imaging at 1.5 T. METHODS 17 prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 degrees, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. RESULTS…

medicine.medical_specialtyMaterials sciencemedicine.diagnostic_testmedicine.medical_treatmentMagnetic resonance imagingBiological effectMr imagingProsthesisSurgerymedicine.anatomical_structureFlip anglemedicineRadiology Nuclear Medicine and imagingAcquisition timeHeart valveBiomedical engineeringProsthetic heartRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Mikrostruktur der Lunge: Untersuchung mittels Diffusionsmessung von hochpolarisiertem 3Helium

2006

Imaging methods to study the lung are traditionally based on x-ray or on radioactive contrast agents. Conventional magnetic resonance imaging (MRI) has only limited applications for lung imaging because of the low tissue density of protons concentration of hydrogen atoms, which are usually the basis for the imaging. The introduction of hyperpolarized noble gases as a contrast agent in MRI has opened new possibilities for lung diagnosis. The present paper describes this new technique. Diffusion-weighted MRI for assessment of the lung microstructure is presented here as an example of the new possibilities of functional imaging. Studies to determine the sensitivity of the diffusion measurement…

ReproducibilityMaterials scienceRadiological and Ultrasound Technologymedicine.diagnostic_testBiophysicsMagnetic resonance imagingTissue densityFunctional imagingNuclear magnetic resonanceHealthy volunteersLung imagingmedicineRadiology Nuclear Medicine and imagingDiffusion MRIZeitschrift für Medizinische Physik
researchProduct